S7 300 Digital input modules
Siemens S7-300 Digital Input Modules — SM 321 and SM 326
Siemens S7-300 digital input modules acquire on/off field signals for the SIMATIC S7-300 system. The SM 321 family includes standard inputs, different input voltage ranges, diagnostic functions and versions for extended environmental conditions. SM 326 modules evaluate safety-related signals in compatible SIMATIC S7 F configurations. The directory below contains 20 SM 321 and 4 SM 326 models, identified by their complete order numbers.
Check the PLC hardware configuration, channel count, AC/DC input voltage, sensor output type and front connector together. The electrical interface of inductive sensors, photoelectric sensors, pushbuttons and limit switches must match the selected input module.
Wiring and supply: select the 24 V DC panel power supply, field sensors and sensor cables for the application. A matching 20-pin or 40-pin connector does not establish identical terminal assignments or module interchangeability. DI means digital input.
SM 321 — 24 V DC digital input modules
6ES7321-1BH00-0AA0 — SM 321 with 16 digital inputs, 24 V DC and optical isolation. Earlier version; match the complete order number to the existing hardware configuration.
6ES7321-1BH01-0AA0 — SM 321 with 16 digital inputs, 24 V DC, optical isolation and a 20-pin front connector.
6ES7321-1BH02-0AA0 — SM 321 with 16 digital inputs, 24 V DC, electrical isolation and a 20-pin front connector.
6ES7321-1BH50-0AA0 — SM 321 with 16 digital inputs, 24 V DC, sourcing inputs, electrical isolation and a 20-pin front connector. The sensor output type and wiring must suit this input circuit.
6ES7321-1BL00-0AA0 — SM 321 with 32 digital inputs, 24 V DC, optical isolation and a 40-pin front connector.
6ES7321-1BP00-0AA0 — SM 321 with 64 digital inputs, 24 V DC, four isolated groups of 16 channels and sinking/sourcing inputs. Requires suitable 6ES7392-1.N00-0AA0 terminal blocks and cables from the 6ES7392-4...0-0AA0 family. Dots identify accessory variants; select the complete code for the connection type and cable length.
SM 321 — Inputs for AC and other DC voltage ranges
6ES7321-1CH00-0AA0 — SM 321 with 16 digital inputs, 24–48 V AC/DC, individual commons and isolation between channels, and a 40-pin front connector.
6ES7321-1CH20-0AA0 — SM 321 with 16 digital inputs, 48–125 V DC, electrical isolation and a 20-pin front connector.
6ES7321-1EH00-0AA0 — SM 321 with 16 digital inputs, 120 V AC, optical isolation and a 20-pin front connector. Keep this earlier order number distinct from later revisions.
6ES7321-1EL00-0AA0 — SM 321 with 32 digital inputs, 120 V AC, optical isolation and a 40-pin front connector.
6ES7321-1FF00-0AA0 — SM 321 with 8 digital inputs, 120/230 V AC, optical isolation and a 20-pin front connector.
6ES7321-1FF01-0AA0 — SM 321 with 8 digital inputs, 120/230 V AC, electrical isolation and a 20-pin front connector.
6ES7321-1FF10-0AA0 — SM 321 with 8 digital inputs, 120/230 V AC, individual commons and channel-by-channel isolation, and a 40-pin front connector.
6ES7321-1FH00-0AA0 — SM 321 with 16 digital inputs, 120/230 V AC, electrical isolation and a 20-pin front connector.
SM 321 — Versions for extended environmental conditions
6ES7321-1BH81-0AA0 — SM 321 with 16 digital inputs, 24 V DC. Isolated version designed for an extended temperature range and environmental conditions.
6ES7321-1BL80-0AA0 — SM 321 with 32 digital inputs, 24 V DC, optical isolation and a 40-pin front connector. Version for extended environmental conditions.
6ES7321-1CH80-0AA0 — SM 321 with 16 digital inputs, 48–125 V DC, isolation in groups of 8 channels and a 20-pin front connector. Version for extended environmental conditions.
6ES7321-1FF81-0AA0 — SM 321 with 8 digital inputs, 120/230 V AC. Isolated version designed for an extended temperature range and environmental conditions.
Check the permitted temperature range, mounting orientation and number of simultaneously active inputs for each model; do not assume one temperature rating applies to every extended-environment version.
SM 321 — Inputs with diagnostics and hardware interrupts
6ES7321-7BH00-0AB0 — SM 321 with 16 digital inputs, 24 V DC, electrical isolation, hardware interrupts and diagnostic interrupts.
6ES7321-7BH01-0AB0 — SM 321 with 16 digital inputs, 24 V DC, electrical isolation, hardware interrupts, diagnostics and isochronous operation; 20-pin front connector. Isochronous operation requires a compatible system configuration.
SM 326 — Fail-safe and NAMUR digital input modules
6ES7326-1BK00-0AB0 — SM 326 with 24 digital inputs, 24 V DC, fail-safe inputs for SIMATIC S7 F systems, diagnostic interrupts and a 40-pin front connector.
6ES7326-1BK01-0AB0 — SM 326 with 24 digital inputs, 24 V DC, fail-safe inputs for SIMATIC S7 F systems, diagnostic interrupts and a 40-pin front connector.
6ES7326-1BK02-0AB0 — SM 326 with F-DI 24 × 24 V DC, fail-safe digital inputs for SIMATIC S7 F systems, diagnostic alarms and a 40-pin front connector.
6ES7326-1RF00-0AB0 — SM 326 with 8 fail-safe NAMUR inputs for SIMATIC S7 F systems, a 24 V DC module supply and a 40-pin front connector. The NAMUR signal interface differs from a standard 24 V DC digital input; select sensors and any Ex application according to the module documentation.
Safety configuration: the physical input count does not represent the same number of independent safety functions in every wiring arrangement. Single- or dual-channel sensor evaluation, the F-CPU, safety program and module operating conditions must be considered together. A module name alone does not establish the safety level of the complete application.
Selection, revision and used-module checks
Isolation and common terminals: “Optically isolated” does not mean that every input is isolated from every other input. Use the wiring diagram to distinguish isolation from the backplane bus, isolation between channel groups and individual channel isolation.
Complete code and project compatibility: two modules with the same channel count can differ in input circuitry, interrupt functions or environmental ratings. Check the S7-300 CPU module, any ET 200M interface, STEP 7 hardware configuration and existing wiring together. Do not automatically apply a later revision’s isochronous operation or module-replacement-during-operation capability to an earlier version.
PDF files and technical documentation
Visit S7-300 PDF files and manuals for wiring diagrams and module documentation. Confirm that the document covers the complete order number and hardware version.
Related topics and categories
S7-300 main page | CPU modules | Digital output modules
Analog modules | Special and function modules | S7-300 memory cards
Siemens S7 PLC range | Used Siemens products | HMI operator panels
Second-hand main page | OtomasyonAVM home | S7-300 files
Manufacturer references
Siemens — S7-300 Module Data | Siemens — S7-300 / ET 200M Fail-safe Signal Modules | Siemens — Front Connector Selection