6ES5 946-3UA21

Siemens 6ES5 946-3UA21 – S5-155U CPU 946 processing unit

Siemens 6ES5 946-3UA21 is the CPU 946 instruction-processing section of the CPU 946/947 assembly for SIMATIC S5-155U. This central processing unit in the Siemens S5 PLC family handles control, arithmetic/logic and address generation. It operates with CPU 947 and should not be treated as a complete standalone PLC.

The accompanying 6ES5 947-3UA21 contains user memory and the programmer interface. The 946 handles processing; the 947 handles memory and communication. Check both modules' complete order numbers, hardware versions and operating system when selecting replacement parts.

STEP 5 programs and memory capacity

The 946/947 system processes STEP 5 programs cyclically and through time-driven or interrupt-driven execution, with floating-point arithmetic support. A PLC programming backup should preserve data blocks and system configuration alongside the program blocks.

The assembly's basic user RAM is 64 Kwords, equivalent to 128 Kbytes, and is physically located on CPU 947. This should not be described as user RAM installed on the CPU 946 board itself. The family manual describes configurations reaching 448 Kwords / 896 Kbytes with suitable 355 memory expansion and memory submodules; the required additional modules must actually be installed.

Single-processor and multiprocessor operation

The 3UA21 generation supports multiprocessing. Sharing the S5 bus between several complete CPU assemblies requires a suitable system with a 923C coordinator. The coordinator allocates bus access to the processors through time slices.

For multiprocessing, verify the I/O assignments in the DB1 address lists and the relevant operating settings in DX0. Installing another processor or a coordinator alone is insufficient. One 946 and its accompanying 947 are also not two independent CPUs; together they form one CPU assembly.

I/O and programmer connection

The family specification lists 256 timers and 256 software counters. Digital inputs, digital outputs and analog I/O use separate modules. Field voltage, channel capacity and output current depend on those modules rather than this CPU order number.

The 15-pin PG connector is on CPU 947; the family manual specifies 9600 bit/s for the serial programmer connection. Use the appropriate S5 programming cable. Assess plant communication modules and interface boards separately; the PG connector is not an Ethernet port.

Supply, dimensions and rack installation

Siemens' technical table specifies a 5 V DC ±5% supply and approximately 6 A consumption for CPU 946. Dimensions are 40.64 × 233.4 × 160 mm, with an approximate weight of 900 g. CPU 946 occupies two rack slots; allow further space in the rack layout for CPU 947 and any memory expansion.

The PLC power supply assessment must include CPU 947 and the other modules in addition to CPU 946. The specification gives IP00 protection and an operating range of 0–55 °C. Maintain the required ventilation and grounding conditions.

Front panel and fault indicators

CPU 946 has RUN/STOP and RESET/OVERALL RESET switches, plus RUN, STOP, SYS FAULT, QVZ, ADF, ZYK and BASP indicators. QVZ indicates an acknowledgement timeout, ADF an addressing error, ZYK an exceeded cycle time and BASP disabled output commands.

The manual's 200 ms default scan-monitoring time is not the actual program cycle time or an instruction-execution time. During fault finding, evaluate the indicators together with ISTACK and the conditions under which processing stopped.

Differences from other order numbers

6ES5 946-3UA11 belongs to the earlier single-processor generation. Siemens states that 3UA21 and 3UA22 are functionally identical and that the change to 3UA22 was made for production reasons. Nevertheless, verify hardware, jumpers and the operating system when selecting 6ES5 946-3UA22 or 6ES5 946-3UA23.

6ES5 946-3UR21 is a different R-coded version and must not automatically be substituted for UA21. Further family information is available in About Siemens S5 PLC.

Editor's note

If a listing shows only the 946, establish whether the 947 is included. The double-width board in the photograph does not constitute a complete working CPU assembly by itself.

Before replacing hardware, back up the program, data blocks, DB1 and DX0. In a multiprocessor installation, record which CPU controls each I/O area so that the assignment can be restored correctly.

Do not start fault investigation with OVERALL RESET. The manual states that this erases and initializes the RAMs. Preserve ISTACK and the working program before making that change.

Do not dismantle the double-width CPU 946 into separate boards; the manual explicitly requires the module to remain assembled. For jumper checks, use the drawing for the exact 3UA21 version rather than copying another revision's photograph.

Test PG communication at the connector on the 947. A RUN light on the 946 is only part of the check; verify program access, data exchange and coordinator operation where applicable in a suitable test setup.

When buying used Siemens equipment, request complete labels and a test record from a 946/947 assembly. Disconnect rack power before removing or inserting modules, and inspect rear connectors, locking parts and cabinet cooling.

OtomasyonAVM resources

Browse the 6ES5 946-3UA21 model page, S5 CPU family, memory modules and used Siemens equipment. The manufacturer manual explains CPU 946 and CPU 947 roles together with the version distinctions.

Related topics and models

+ 6ES5 947-3UA21: the assembly's memory and programmer-interface section.

+ 6ES5 946-3UA11: the earlier single-processor generation.

+ 6ES5 946-3UA22: the production version Siemens describes as functionally identical to 3UA21.

+ 6ES5 946-3UA23: a later version; assess hardware and software compatibility separately.

Other S5 equipment

Siemens S5 PLC · CPUs · Memory · Racks · Cables · Communication · Used Siemens equipment

Manufacturer document and external reference

+ Siemens S5-155U CPU 946/947 Manual – 6ES5 998-0UM22, Release 07, English: construction and functional division on PDF pages 127–130; specifications on 132–133; front panel and reset on 137–142; 3UA21 jumper drawing on 148; 3UA21/22 features on 315. These are physical PDF page numbers.