6ES5 385-8MA11
Siemens 6ES5 385-8MA11 385A Dual-Channel Counter Module
The 6ES5 385-8MA11 is the 385A module with two independent down-counter channels for SIMATIC S5. This S5 special module handles pulse counting independently of the CPU scan. Set a starting value of 0–999 for each channel using the front thumbwheels. The input frequency is up to 500 Hz.
Pulse inputs and zero outputs
Set each channel’s front switch for 5 V DC TTL or 24 V DC pulses. For a sensor such as a photoelectric sensor, match its output level, cabling and channel common to the Siemens diagram. Pulses go to the module’s own inputs. The PLC reads the channel’s zero status.
At zero, the channel’s green Q LED and 24 V DC field output turn on. The isolated outputs use an external load supply rated at 24 V DC with a permitted range of 20–30 V DC. Each output is rated at 0.5 A. Siemens specifies a 2 Hz switching limit for inductive loads such as a relay. The red F LED indicates an output short circuit.
Slot, addressing and spare selection
Siemens documents the 385A for S5-90U, S5-95U, S5-100U, ET 100U and ET 200U. ST 50 lists only the 385B for S5-95F. For an S5-100U with a CPU 100 or CPU 102, check the slot and module-count limits in ST 50. The S5 PLC program sets the channel’s output bit to load the start value and enable counting. Clearing that bit switches off the field output. The PLC reads zero status from the corresponding input bit. For ET 200U, use the addresses configured in the station project.
The 385A fits on an S5 bus unit. An installation may use the 700-8MA11 screw-terminal, 700-8MA21 crimp-terminal or 700-8MA22 crimp-terminal version. Match the slot coding, bus-unit label and terminals to the existing installation.
The 385B 6ES5 385-8MB11 is a single-channel counter and position acquisition module rated for 25 kHz at 24 V or 500 kHz at 5 V RS-422. The 380-8MA11 is a timer. For a 385A spare, match the 8MA11 suffix, both channel settings and the PLC address.
Editor’s note
Record the front settings before removal. Follow the plant isolation procedure. Photograph both three-digit presets, the 5/24 V selector positions and the slot number.
Test each channel with five pulses. On the bench, set the preset to 005, enable the channel from the PLC and apply five pulses at the selected input level. Check the green LED, PLC input bit and field output separately on the fifth pulse.
Check the load command if pulses are present but counting fails. Look for the PLC output bit’s 0-to-1 transition. That transition loads the preset. Then confirm the pulses reach the intended channel input.
Check the output circuit if the green LED is on but the load is idle. Trace external L+ and M, the channel terminal and the load wiring. If the red F LED is on, check the output wiring and load for a short circuit.
Measure frequency if pulses are missed as the machine speeds up. Measure the sensor signal at the highest normal operating speed. Compare it with the 500 Hz limit and the selected 5/24 V input level.
Ask for a two-channel test when buying used. Look for evidence that both presets can be changed, each channel switches at zero and its output turns off when the PLC enable bit is cleared.
To offer a 385A for sale, send the full order number, a photo of the front settings and any two-channel test results to otomasyonavm@gmail.com.
PDF manuals and wiring diagrams
+ Siemens S5-100U manual (English) · Section 15.5, wiring and addressing.
+ Siemens S5-90U/95U manual (English) · Section 16.5.
+ Siemens ET 200U manual (English) · Section 9.5.
+ Siemens ST 50 catalog (English) · pp. 2/62–2/63, 385A and 385B.
+ 6ES5 385-8MA11 Siemens data sheet (German)
Related topics
+ What is a high-speed counter?