6ES5 100-8MA01

Siemens SIMATIC S5-100U CPU 100 — 6ES5 100-8MA01

The Siemens 6ES5 100-8MA01 is the SIMATIC S5-100U CPU 100, which combines the processor and power supply in one housing. This SIMATIC S5 CPU runs on 24 V DC and has RAM for 1,024 statements, plus 16 timers and 16 counters. The system supports up to 128 digital I/O points and 8 analog I/O channels, with each limit counting inputs and outputs together.

On the machine, S5 digital input modules pick up signals from pushbuttons, limit switches and sensors. An input module such as the 6ES5 430-8MB11 passes the signal state to the CPU. The CPU executes the logic and updates the S5 digital output modules.

Supply terminals and bus connection

The L+ and M terminals take a nominal 24 V DC supply. The permitted range is 18–34 V DC including ripple, with a maximum CPU input current of 0.8 A. The CPU supplies +9 V to the I/O electronics through the bus. When sizing an external 24 V supply such as the 6ES5 930-8MD11, account for field loads separately.

In the S5 mounting arrangement, a ribbon cable connects the DIN rail-mounted CPU to the first 6ES5 700-8MA11 type bus unit. The early S5-100U manual shows a direct connection for the PG 605U and PG 615U. Match the S5 programming cable to the programming device.

Program capacity and memory

The CPU provides 1,024 flag bits, of which 512 are retentive. A binary operation takes approximately 70 µs. A copy of the PLC program can be stored on a plug-in S5 EPROM or EEPROM memory submodule. Check that the backup fits the CPU’s 1,024-statement limit.

CPU versions and intelligent module support

The 6ES5 100-8MA02 is a separate CPU 100 order number. The CPU 102 8MA01, CPU 102 8MA02, CPU 103 8MA01 and CPU 103 8MA02 each have their own hardware and program requirements. The IP 267 stepper motor controller is incompatible with CPU 100 8MA01.

For a system with the CP 521 BASIC 6ES5 521-8MB12, the CPU 100 8MA01 must be at hardware revision 6 or later. Check both the order number and hardware revision on the CPU label. This CPU does not support SINEC L1 networking.

Checking output faults

When troubleshooting a PLC, check the output load supply separately from the connections to the S5 expansion modules and any S5 interface modules. On the 6ES5 440-8MA12 and 6ES5 440-8MA22 output modules, check the red fault LED. This CPU cannot read these module fault bits at I X.0 and I X.1.

Editor’s note

Label. Record the full 6ES5 100-8MA01 order number and the hardware revision when sourcing a spare.

Supply. If the CPU fails to start, compare the voltage at the power supply output and at the CPU’s L+ / M terminals under load.

Backup. Save the program from the CPU with the PG if it is readable. Photograph the order number and orientation of the fitted memory submodule before removal.

Bus connection. If several I/O modules drop out together, isolate the supply and inspect the ribbon cable between the CPU and the first bus unit.

Test run. After fitting a spare, confirm RUN and check the input response. Test the field outputs one at a time under controlled conditions.

OtomasyonAVM resources and PDFs

SIMATIC S5-100U modules and accessories · SIMATIC S5 CPU family · OtomasyonAVM Siemens SIMATIC S5 PDF archive

Related topics

6ES5 100-8MA02 CPU 100 · 6ES5 102-8MA01 CPU 102 · 6ES5 103-8MA01 CPU 103 · 6ES5 700-8MA11 bus unit

Back to the S5 range

S5-100U modules · Siemens SIMATIC S5 · Used Siemens automation equipment

If you have an S5-100U CPU to sell, send a label photo, quantity and operating condition to otomasyonavm@gmail.com.

Siemens and external references

SIMATIC S5-100U system manual, §6.3.3 CPU 100 8MA01 specifications (Russian)

Siemens SIMATIC S5-100U system manual, §6.4.1 output diagnostics

Siemens IP 267 manual, CPU compatibility · Siemens CP 521 BASIC manual, CPU hardware revisions