6ES5 314-3UR11

Siemens 6ES5 314-3UR11 – IM 314R Interface for Switched I/O

Siemens 6ES5 314-3UR11 is the IM 314R expansion interface for switched I/O in S5-115H and S5-155H systems. Part of the S5 interface module range, it connects an expansion unit to the redundant control system through the central controller’s 6ES5 304-3UB11 / IM 304.

It has two 50-pin front connectors for the 721 cable chain. The total cable length from IM 304 to the last IM 314R is 600 m maximum, with up to four expansion units per line. Assess the cable length together with the actual connection arrangement.

Redundant connection and rack arrangement

Each central controller contains an IM 304, while each switched expansion unit contains two IM 314R modules, providing access from control sides A and B. Relevant installation examples include the ER 701-3LH expansion rack for S5-115H and the EG 185U expansion unit for S5-155H.

Check the S5 rack and mechanical arrangement. Select mounting parts, such as the 491-0LB11 adapter casing needed for compact boards in an S5-115H installation, to suit the actual rack. Record the existing casing code and board retainers before replacement.

Supply and power budget

The IM 314R uses the rack’s 5 V DC system supply. Catalog ST 50 specifies 1 A maximum current consumption and 5 W maximum power loss. Assess the S5 power supply capacity with both interface modules and the other modules installed in the rack.

721 cable and correct termination

X3 accepts the 721 cable from the IM 304 or preceding station. X4 continues to the next station; at the end of the chain it accepts the 6ES5 760-0HA11 terminator. Match S5 cables and connectors by their complete order codes and pin assignments.

Check grounding and equipotential bonding against the installation drawings. When investigating electromagnetic interference, inspect the shield, connector fastenings and cable route together. Label the A-side and B-side cables clearly at both ends.

EU number and project configuration

In S5-155H, both IM 314Rs in the same expansion unit must have the same EU number selected on switch S1. This number must match the I/O area configured in COM 155H. Back up the PLC program, the applicable COM 115H / COM 155H configuration and the physical switch settings.

The IM 324R parallel link module serves the connection between the two control sides; the IM 314R manages access to the switched expansion unit’s I/O. When examining a Siemens S5 system, trace each cable to its module and port using the project documentation.

LED indications and fault checks

F, green: master status. R, yellow: standby / ready to take control. T, red: test status. BF, red: a fault or the associated central controller at STOP. Read the indicators together and compare them with the system’s operating state.

Check digital inputs and digital outputs separately. In S5-155H, the IM 314R’s test state disables the expansion unit’s digital outputs through BASP. During troubleshooting, record master/standby status, the EU number, cabling and termination before proceeding to channel tests.

Editor’s note

Start with the complete code: this is 314-3UR11, the IM 314R. Similar-looking versions such as 314-3UA11 and 314-3UH12 need their own compatibility checks. The suffix matters in a redundant system.

Give the terminator the same attention as the main module. Check the 760-0HA11 code at X4 on the last IM 314R. Keep a photograph and mark the end of the cable chain; both will be useful when tracing a later fault.

Label the two control-side cables A and B before disconnecting them. Keep the cable label, port designation and EU number in one record. A few written lines are easier to rely on than memory when the installation stretches across a large area.

If BF lights, pause before ordering a card. Is the associated CPU at STOP, is the other side ready, and is the terminator fitted? Check these points and record the LEDs. Replacing a sound module can obscure the evidence without resolving the original fault.

When buying a used Siemens module, ask for more than illuminated LEDs. Verify both connection paths and a controlled takeover on a suitable test setup. A written result identifying the EU number and cable used makes the test much easier to assess.

OtomasyonAVM resources and PDFs

+ S5 interface modules · IM 304 interface module · IM 314R terminator

+ S5-115H system manual – English, our PDF archive. Printed page 3-25 / PDF page 75: IM 314R indications and the 760-0HA11 terminator.

+ Siemens S5 shared PDF archive and manuals

Related topics

+ 6ES5 701-3LH11 · 6ES5 185-3UA11 · 6ES5 324-3UR11

+ 6ES5 314-3UA11 · 6ES5 314-3UH12: other IM 314 versions; assess their system and revision requirements individually.

Browse SIMATIC S5

+ S5 interface modules · S5 racks · SIMATIC S5

+ Siemens S5 PLC · Siemens second-hand equipment

Siemens and external references

+ Siemens S5-155H Manual, Volume 1 – English; C79000-G8576-C197, Edition 06. Section 6.4 covers installation, S1/EU numbering, X3/X4 and LEDs; section 11.1 gives IM 314R specifications.

+ Siemens ST 50, 1998 – English; S5-135U/155U/H catalog section. Printed pages 4/152–4/153 cover the IM 304 / IM 314R arrangement, the 314-3UR11 order code, power figures and terminator.