Delta DVP16EH00R

Delta DVP16EH00R – EH PLC with 8 inputs and 8 relay outputs

The Delta DVP16EH00R is a first-generation Delta DVP-EH PLC main unit with a 100–240 V AC supply, 8 digital inputs, 8 relay outputs and 16K-step-class program memory. In compact machines it reads sensors, pushbuttons and limit switches and controls loads such as valves, contactor coils and indicator lamps.

Inputs and expansion addresses

The built-in digital inputs use X0–X7 and the outputs use Y0–Y7. Check the 24 V DC input circuit and S/S common when wiring inductive sensors or limit switches. Match the S/S connection to the PNP or NPN field circuit.

Delta’s programming manual assigns the DVP-16EH expansion inputs from X20 and expansion outputs from Y20. If the program uses an incremental encoder or high-speed counter, check the X address, counter mode and signal frequency together.

Relay outputs and C common terminals

The 16EH terminal drawing pairs each Y0–Y7 output with its corresponding C0–C7 terminal. For example, C3 is the common for Y3. The load is powered by an external supply through the corresponding C terminal. Delta’s sheet specifies 2 A per point and about 10 ms switching delay for the relay outputs. Check load type and inrush current separately.

Use suitable fusing and suppression for coil loads. A suitable flyback diode limits the voltage spike when a DC coil is switched off. The relay contacts switch loads on and off. Select a CPU with suitable pulse outputs for high-speed positioning.

Programming software and cable

Use WPLSoft to read, edit and monitor an existing ladder program. If your ISPSoft version supports the first-generation EH target, set up the serial connection in COMMGR. Select the original EH target in the PLC programming software and save the original project file before conversion.

COM1 RS-232 uses an 8-pin mini-DIN connector for programming. Use a DVPACAB2A30 Delta PLC cable with the PC’s DB9 serial port. For a USB connection, pair it with a suitable USB-to-RS-232 adapter, install the driver and select the COM port assigned by Windows.

COM2 RS-485 is the built-in port for field communications. On a Modbus RS-485 link, match the station address, serial settings and ASCII or RTU mode with the connected device.

Related Delta models

The DVP16EH00T has the same 8 inputs and 8 outputs with transistor switching. The first-generation DVP20EH00R has 12 inputs and 8 relay outputs. The DVP16EH00R2 belongs to EH2 and the DVP16EH00R3 to EH3. Both have 8 inputs and 8 relay outputs. Before replacing a CPU, compare terminals, expansion and software targets together.

Editor’s Note

Ask for the full nameplate. When buying used, get photos of the model code, supply rating and output terminals.

Test all eight outputs individually. Even if the Y LED responds correctly, use a suitable test load to check each contact and its own C terminal.

Check both switching states. If the load stays on after the output command turns off, check separately for a welded contact and a backfeed from the field circuit.

Back up before battery work. Save the program, required retained values and serial settings. If the system has expansion, record the addresses starting at X20 and Y20.

If inputs flicker when a coil energises, check grounding, the 24 V field supply and electromagnetic interference. See the PLC FAQ for input, output and scan-cycle topics.

Internal references and PDFs

Delta DVP PLC files

Related topics · Delta DVP PLC series · Delta PLC · Used Delta equipment

External references

Delta DVP-EH instruction sheet, 5011621601-EHE1 · Delta DVP-PLC programming manual, §2 · Delta WPLSoft and ISPSoft explanation