Delta ASMT
Delta ASMT Servo Motors
Delta ASMT is a family of rotary AC servo motors documented for ASDA-A drives, with ratings from 100 W to 3 kW. The family includes low-inertia L and medium-inertia M models. To preserve axis control on an existing machine, match the motor, servo drive, brake option and cable set by their full model codes.
How to read an ASMT motor code
In ASMT01L250AK, 01 denotes 100 W, L denotes low rotor inertia, and 250 denotes a 2,500 PPR encoder. The final two characters specify hardware options. A indicates a motor without a brake and B indicates an electromagnetic brake. The final K specifies a keyway without an oil seal, O specifies an oil seal without a keyway, and M specifies both.
The ASDA-A drive uses quadrature decoding to process the 2,500 PPR incremental encoder signal as 10,000 counts per revolution. For the feedback connection, check the CN2 cable and motor-side connector against the drawing for the exact model.
L and M models and drive matching
Low-inertia L series: ASMT01L250, ASMT02L250, ASMT04L250, ASMT07L250, ASMT10L250, ASMT20L250 and ASMT30L250.
Medium-inertia M series: ASMT10M250, ASMT15M250, ASMT20M250 and ASMT30M250.
1 kW example: Delta lists the ASMT10L250□□ at 3,000 rpm and 3.3 N·m rated torque, with a 100 mm flange and an ASD-A1021L□ drive. The ASMT10M250□□ is rated at 2,000 rpm and 4.8 N·m, with a 130 mm flange and an ASD-A1021M□ drive. Both motors have a standard 22 mm shaft. Check the coupling, flange and load inertia separately.
In the 400 W class, Delta lists the ASMT04L250□□ with the ASD-A0421L□. For the legacy ASD-B0421-A drive, the ASDA-B manual lists ECMA options including ECMA-C30604□S. Start motor and drive selection with the matching table for the drive you have. Squares indicate order-code options.
ASMT technical documents
ASDA-A installation sheet · ASMT matching table (EN) · Two pages, with L and M motor and drive combinations on the first page.
ASDA-A/A+ manual · ASMT motor data (EN) · Model codes on page 1-5, ASMT matching on page 1-7, specifications in sections 11.3 and 11.4, and dimensions in sections 11.9 and 11.10.
OtomasyonAVM copy of the manual · ASDA-B motor matching table · Delta servo PDF archive
Editor’s Note
Read the final two letters on the nameplate when buying used. Ask for photos of the label, flange, shaft end and both connectors. During bench inspection, check for bearing noise, shaft play and keyway wear. A test record should identify the motor code, compatible drive and test conditions.
Record axis position if AL011 occurs intermittently. On the ASDA-A, this code indicates a position detector fault. If the alarm repeats in the same part of the stroke, safely isolate power before inspecting the CN2 connector latch and the moving cable at that bend. If it recurs as load current rises, investigate signal noise along with cable routing and shield termination.
Save the axis settings before replacement. Record the electronic gearing ratio, I/O assignments and home return settings from the old drive. Compare P1-44/P1-45 on the ASDA-A. On the first controlled trial, verify measured travel against a known machine distance.
On a braked motor, check the load and holding function first. Secure a vertical load mechanically before servicing the axis. The motor brake holds position at standstill. If fast deceleration causes overvoltage, review stop time, load and the drive’s regenerative braking arrangement separately.
Compare mechanical dimensions before tuning an L or M replacement. Differences in flange size and inertia can affect coupling alignment and axis response even at the same power rating. If vibration appears at a specific speed, check the coupling, bearings and mounting. Then assess auto-tuning and servo gain under the machine’s actual duty cycle.