6ES5 955-3LC12

Siemens 6ES5 955-3LC12 SIMATIC S5 EU 183U Power Supply

The Siemens 6ES5 955-3LC12 is a two-fan SIMATIC S5 power supply for the 6ES5 183-3UA12 EU 183U expansion rack. Siemens specifies a selectable 110 or 220 V AC input, ±15%, 47–63 Hz for this order number. The main output is 5.1 V DC (±1.2%) at 18 A and the auxiliary output is 24 V DC at 0.8 A.

The 3LC12 converts cabinet AC power to the DC rails used in the SIMATIC S5 system. The 5.1 V rail powers the rack internally, and two fans move air through the expansion unit. When the rack loses power, the S5 interface modules can also indicate a fault. Record the power supply, fan and interface indications together to establish what happened first.

Which rack uses the 3LC12?

The Siemens EU 183U manual lists the 3LC12 with the 183-3UA12 rack. Edition 07 of the system manual pairs the 183-3UA13 expansion rack with the 6ES5 955-3LC42 and also lists that supply with the 188-3UA12 central controller. The 3LC42 has a 1 A rating on its 24 V output. The 3LC12 is rated at 0.8 A on that output.

The S5-135U 135-3UA11 central controller and the 185-3UA11 EU 185U rack are examples of other AC-fed assemblies with an 18 A main supply. For a replacement, check the complete S5 rack order number and the installed power supply label against the rack documentation.

Input selector and output ratings

The S10/S11 selector arrangement sets the input voltage. Siemens gives a rated-load input current of 1.2 A at 220 V AC or 2.4 A at 110 V AC. Some parts listings use 115/230 V. Check the label and the existing selector position on the unit being serviced. The 3LC13, 3LC14 and 40 A 3LF12 have their own order numbers.

In the documented EU 183U rack, the 24 V auxiliary output has no connection to the backplane. Use the cabinet drawing to trace field power for the S5 digital input modules and digital output modules. The front Test 5 V point is for voltage measurement. The point marked 3 V ≙ 18 A is for monitoring main output current.

Why can a fan fault shut down the outputs?

The monitoring circuit detects the loss of one or both fans and signals it through an LED and relay. With the F–R jumper closed, a fan fault shuts down the outputs. Where racks share a fan monitoring circuit, one fan fault can shut down other racks in the group. Record which rack indicated the fault first.

Editor’s note

Photograph both nameplates. Keep the 183-3UA12 rack number and the 3LC12 suffix in the same service record. The 3NC12, for example, takes a 24 V DC input.

Document the connections before removal. Once qualified maintenance staff have isolated the supply, record the selector position, the F–R jumper and the markings on the S5 cables and connectors.

Have both fans checked if a fan LED comes on. Establish whether the fault started at a fan, in the air path or in the shared monitoring circuit. If several racks stopped together, consult the group monitoring diagram.

Verify the program backup before the shutdown. Confirm that the Siemens S5 PLC program backup is available and record the S5 memory card type. During restart, check the central CPU and expansion rack indications separately.

Ask for a load test in a compatible rack when buying used. The record should show the 5.1 V and 24 V outputs, the loads applied and the condition of both fans. Use the S5 hardware and maintenance guide alongside the documentation for the actual rack.

OtomasyonAVM resources and PDFs

6ES5 183-3UA12 EU 183U expansion rack · SIMATIC S5 hardware overview and system manuals

OtomasyonAVM S5 PDF archive. The external references below include the EU 183U manual that lists the exact 3LC12 order number.

Related topics

955-3LC13, AC-input supply with an 18 A main output · 955-3LC14 power supply · 955-3LC42 and its rack assignments

S5 navigation

SIMATIC S5 · S5 power supplies · S5 expansion units · S5 racks

External references

Siemens EU 183U/184U operating instructions, 3LC12 technical data (Russian PDF). Printed pages 1-9 and 1-10 cover the input, outputs and fan monitoring. Page 1-17 shows the front panel.

Siemens S5-135U/155U system manual, edition 07 (English PDF). Printed page 4-19 covers the 3LC42 variant and its rack assignments.