6ES5 580-0UA12
Siemens 6ES5 580-0UA12 — CP 580, 4 MB RAM and 40 MB Hard Disk
Siemens 6ES5 580-0UA12 is a CP 580 communications processor listed with 4 MB RAM, a 40 MB hard disk and no 80387 coprocessor. Within the Siemens SIMATIC S5 family, this communications and data-processing unit provides an industrial AT-computer platform as part of the S5 auxiliary equipment range.
The S5 CPU executes the PLC control tasks, while the CP 580 adds computing resources for acquiring, storing and processing data. For industrial communication, assess the CPU–CP backplane connection together with the application running on the CP. Preserve the machine program and the CP’s disk contents as separate backups.
4 MB RAM and the 40 MB hard disk
4 MB describes working memory; 40 MB describes hard-disk capacity. A RAM specification does not establish that application files are present on the disk. An S5 memory module is also a different storage medium from the CP’s hard disk; inspect which components and files are included.
A used CP 580 may have had its original disk replaced. Check the fitted disk label, detected capacity and readable files. When comparing it with a CP 581 basic board or the CP 581-1EA11 with silicon disk, assess the storage arrangement and software environment as well. Direct replacement suitability should not be assumed.
MS-DOS and CP 580 system functions
Siemens’ CP 580 family manual describes an MS-DOS environment, CPRECORD for data acquisition, CPMASS for storage operations and CPSHELL as a command interpreter. A software assessment should cover the operating system, drivers, application and configuration files together. Data-transfer calls in the PLC program must also match the CP software in use.
The documentation supplement explains that CPSHELL job status reports CPU–CP data transfer; it does not by itself confirm execution of the requested command. Verify the expected file, recorded data or application result as well as the status bits.
Addressing and interface number
In a SIMATIC S5 installation, check the CP’s base interface number against the SSNR parameter in the program’s data-handling blocks. For S5 interface settings, use photographs of the existing coding switches and the working project as references. Record the original settings before changing switches during a replacement trial.
Serial connections, display and rack checks
The family manual treats COM 1, COM 2, IF1/COM 3, IF2/COM 4, keyboard and display connections separately. Match S5 connecting cables to the port’s function and electrical arrangement. When selecting a USB-to-RS232 converter, connector shape alone is insufficient; verify the interface type and wiring.
Check the installation position, mechanical arrangement and power-supply loading in the S5 rack together. Preserve cable screening and grounding connections, and label connections before removal. Handling a disk-based assembly also calls for checking mechanical damage and loose connections.
Distinguishing UA11 and UA12 revisions
The available Siemens CP 580 Release 02 manual lists UA11 revisions, including 6ES5 580-0UA11. It is used here as a family and software reference. UA12-specific pin assignments, current consumption and processor frequency should not be transferred directly from that earlier revision. The manual’s supplement also states that the CP 580 is not intended for the S5-150U.
Fault-finding and used-unit acceptance
During fault-finding, record the startup stage, displayed messages and disk activity. For Siemens S5 maintenance, a successful power-up is insufficient: test application loading, file access and actual data exchange with the CPU together.
An acceptance record should identify the complete part number, RAM, fitted disk, coprocessor status, included software and test results. Comparing the original model description with the used assembly’s present condition helps identify missing or previously replaced components.
Editor’s note
Check RAM and disk capacity separately. A 4 MB memory label does not describe the hard disk, and a 40 MB disk description does not establish that the machine’s files are complete.
If the unit starts, preserve a disk backup and the machine-specific files first. Record the application and configuration before using the original disk for any installation trial.
Do not format a disk simply because startup fails to detect it. Examine the drive definition, connections and startup message together. Incorrect settings and disk faults may look similar, and an unnecessary write can destroy recoverable files.
For communication faults, compare the board’s interface number with the program’s SSNR value. Keep photographs of the working board’s switches; a replacement may retain settings from another machine.
Verify the application’s actual result during a used-unit test. A changed status bit is insufficient: inspect the recorded file or the received data, then repeat the test after warm-up.
OtomasyonAVM resources and PDFs
See S5 communications modules, S5 cable types and About Siemens S5 PLC for related information. General documents are collected in the Siemens S5 PDF archive. The CP 580 family manual and part-number listing are linked below with their scope identified.
Related topics
+ 6ES5 580-0UA11 — earlier CP 580 revision.
+ 6ES5 581-0EA11 — CP 581 basic board.
+ 6ES5 581-1EA11 — CP 581 basic board with silicon disk.
+ S5 interface modules · S5 racks.
Browse SIMATIC S5
S5 communications modules · S5 auxiliary and expansion modules · SIMATIC S5 · Siemens S5 PLC · Used Siemens equipment
Siemens and external references
Siemens CP 580 — Manual, Release 02, 6ES5 998-1AT21 — English manufacturer manual with the 11/1991 supplement. PDF p. 31 lists UA11 model coverage; PDF p. 394 describes the hard disk. This is not presented as a dedicated service document for the UA12 revision.
TPCOVN — Siemens SIMATIC parts list — PDF p. 16 identifies the exact 6ES5580-0UA12 part number with 4 MB RAM, 40 MB and no 387 coprocessor. This commercial identification list is not a Siemens electrical data sheet or pin-assignment document.