6ES5 580-0UA11
Siemens 6ES5 580-0UA11 – CP 580 Industrial Computer, 80386SX and 4 MB DRAM
Siemens 6ES5 580-0UA11 is the CP 580 rack-mounted industrial computer for SIMATIC S5. It has an 80386SX processor running at 20 MHz and 4 MB DRAM; this order number specifies a version without a mathematics coprocessor. Within the S5 expansion equipment range, it provides computer-based processing and storage of PLC data.
The documented hardware configuration includes a 40 MB hard disk and a 3.5-inch, 1.44 MB floppy drive. Running under MS-DOS, the CP 580 supports process data acquisition, file storage and commands initiated by the PLC CPU. Communication with the CPU takes place through the S5 backplane bus within the SIMATIC S5 system.
Order number, hardware and installed software
Keep the distinction between this unit and 6ES5 580-0UA12; similar names do not establish identical hardware or software. The CP 581 basic board 0EA11 and CP 581/486 basic board 0EC12 belong to other CP 581 versions. Moving from a CP 580 to these devices requires a separate review of construction, drivers and application files.
On used equipment, installed storage and memory may differ from the original configuration. When assessing S5 memory hardware and files held on the CP, record the label, startup information and available application backup together. Disk capacity alone does not identify the complete device version.
S5 compatibility and rack installation
The manual covers S5-115U, S5-135U and S5-155U systems. The November 1991 documentation supplement explicitly excludes S5-150U use. Match the S5 rack and CPU to the applicable installation table; check the exact revision and application requirements for CPUs such as CPU 928 and CPU 946.
The CP 580 occupies four S5 slots in S5-135U and S5-155U systems. Locate it according to the drawings for carriers such as 6ES5 135-3UA11 and 6ES5 135-3UA21. For S5-115U arrangements using CR 700-0LB or CR 700-3, assess the adapter casing, fan and power supply requirements together.
Supply requirements and connections
The supply rails are +5 V and +24 V. The manual specifies 5.5 A typical consumption at 5 V, rising to a maximum of 7 A for approximately five seconds during restart. Consumption at 24 V is 0.1 A maximum without peripheral devices. Include startup loading when assessing the S5 power supply and PLC power supply modules.
Front connections include 25-pin COM1, 9-pin COM2, the keyboard connection, IF1/IF2 interfaces and three coaxial sockets for colour video. Select connecting cables by pin assignment and signal type as well as connector shape. The S5 interface hardware must match the intended connection; an ordinary VGA cable should not be assumed suitable for the monitor output.
SSNR addressing and CPU synchronization
The CP 580 dual-port RAM contains four pages of 1 KB each. Select a base interface number from 0 to 252 in multiples of four. A base number of 12, for example, assigns SSNR numbers 12, 13, 14 and 15. The SSNR parameter in the CPU’s data handling blocks must match the setting on the CP.
CPU communication uses the SYNCHRON data handling block and the relevant CPIDHB driver on the CP side. The CP can take longer to start than the CPU. When diagnosing S5 communication functions, check addressing, drivers and synchronization together; successful S5 maintenance requires more evidence than the RUN/STOP indicators alone.
Editor’s Note
Treat the disk contents as part of the equipment’s value. Preserve system and application files before considering a format or reinstall. With used Siemens equipment, a startup screen does not establish that the machine application is complete.
If the disk clicks, startup becomes unusually slow or read errors appear, avoid repeated restart attempts. Prioritize preserving the data. Record the fitted disk separately from the original specification, as components may have been replaced over the years.
Photograph the SSNR switches and jumpers before removal. If other CPs share the rack, check for duplicate interface numbers. Losing the previous settings can make a serviceable module appear defective.
Inspect the fan and 5 V supply alongside the enclosure and connectors. Startup loading matters. If the unit works when cold but becomes unreliable after warming up, assess airflow, connections and supply condition separately.
Ask to see CPU synchronization and an actual data transfer where possible, rather than only an MS-DOS screen. Remove power before inserting or removing the assembly. Establish exactly which functions were tested before purchasing.
OtomasyonAVM resources and PDFs
Start with S5 expansion equipment, S5 racks and the SIMATIC S5 overview. The OtomasyonAVM S5 PDF archive provides a starting point for documents. The technical source is the English CP 580 Manual, 6ES5 998-1AT21, Release 02, together with the November 1991 documentation supplement at the beginning of the same file. Chapter 2 covers installation and addressing, Chapter 3 covers CPU interaction and Chapter 11 lists technical data.
Related topics
+ CP 580 0UA12 · CP 581 0EA11 · CP 581/486 0EC12 · CR 700-0LB rack
Browse SIMATIC S5
+ S5 expansion equipment · S5 racks · S5 communication modules · SIMATIC S5 · Used Siemens overview
Siemens and external references
Siemens CP 580 Manual — 6ES5 998-1AT21, Release 02, English; Documentation Supplement 11/1991