6ES5 396-0UA11
Siemens 6ES5 396-0UA11 — OP 396 operator panel, 8 × 20 characters
Siemens 6ES5 396-0UA11 is the OP 396 operator panel for Siemens S5. It has an 8-line × 20-character LCD, contrast adjustment and a 30-key membrane keypad. Its functions include viewing SIMATIC S5 process values, entering setpoints and displaying configured status and fault messages.
It supports handheld, desktop and suitably equipped cabinet installation. The operating system and user project reside on plug-in memory submodules, so check which submodules are included when buying used.
Memory receptacles and CPU compatibility
Receptacle 1 holds the operating system; receptacle 2 holds the user project. The 6ES5 816-0AA11 system submodule and COM 396 user memory have separate roles. User configuration capacity is up to 32 KB EPROM or 16 KB EEPROM. The manual lists 6ES5 375-0LC41, 16 KB EEPROM for user configuration or data dumping.
The installed S5 memory submodule number and version affect CPU compatibility. For example, Siemens lists 6ES5 816-0AB11 for S5-155U; the 0AA11 table has a different scope. Check submodule labels and compatibility with the PLC program. Do not withdraw the operating-system submodule during operation.
PLC connection, power and printer port
Interface 1 is the 15-pin PLC port: AS 511, TTY/20 mA, 9600 baud. Use an appropriate S5 cable. The manual specifies direct connection for S5-95U, S5-100U, S5-101U and S5-115U, and a power adapter for S5-90U, S5-135U, S5-150U and S5-155U.
Operating power comes through the PLC port or a suitable adapter assembly. The 6ES5 984-2UA11 adapter/power-pack assembly is the 220/240 V AC mains version; that voltage must not be applied to the panel’s serial port. Verify the interface arrangement together with the power equipment.
Interface 2 is the 25-pin printer/diskette port. Its basic arrangement is passive TTY. V.24/RS-232 or active TTY operation requires the appropriate adapter. As with other S5 communications hardware, match the signal specification rather than connector appearance.
Process values, commands and addresses
Displayed states come from PLC addresses defined in the project. Compare digital input information with the sensor’s condition and digital output information with the load’s response. For combined I/O modules, check the panel text, program address and field terminal together.
The panel can change setpoints and communication flags; function-key effects depend on the user project. Identify the resulting action before testing a command. For displayed analog values, verify the DB/DW address, data format, scaling and unit. A correct-looking heading does not establish access to the correct address.
Cabinet mounting and protection
The handheld rating is IP40. Siemens specifies IP54 for cabinet mounting with the appropriate frame; the 6ES5 982-3UB11 mounting frame is one documented option. Do not assume that rating without the required frame, sealing and installation conditions.
Operating temperature is 0…+45 °C, with an approximate weight of 1.5 kg. Inspect the membrane, display window, rear support and mounting points on used equipment. Avoid stressing an ageing plastic casing by overtightening its mounting parts.
Error messages and functional checks
ERROR 10 means the PLC has not answered a data request; ERROR 04 indicates a missing user EPROM. ERROR 50 concerns reentry of the date, time and prompter times after power loss; check clock-battery condition as well. During PLC debugging, record the code together with the connection and memory configuration.
Do not assume another panel such as the OP 393 or OP 395 is a direct replacement because it looks similar. Check system memory, user project, cable and power requirements against each panel’s documentation.
Editor’s note
When buying a used Siemens OP 396, inspect both memory receptacles. A panel without the operating system or user project will not automatically recover the machine’s original screens.
For a blank display, first verify the correct power arrangement, connection and contrast setting. Once characters appear, inspect all lines and test consistent keypad response. Readable text alone does not verify every function.
Do not condemn the panel solely because ERROR 10 appears. Verify the CPU, cable and required power adapter. A missing response can originate elsewhere in the connection.
Keep ERROR 50 separate from user-project faults. The battery backs up the CMOS clock. Replace it using the specified type and procedure, then check the date, time and any configured timed functions.
Before testing a key, establish which flag or setpoint it changes. Keep affected loads under control during the test. Afterwards, verify normal operation at the machine as well.
For legacy S5 systems, record more than the panel number. Include the 816 system submodule, user EPROM/EEPROM, cable and adapter in the same record. Preserve a working project backup; recovering the machine-specific files can be harder than finding the hardware.
OtomasyonAVM resources and PDFs
+ Siemens S5 PDF archive: system and module documents. The manufacturer’s OP 396 manual is linked under external references below.
+ 6ES5 396-0UA11 model page and used Siemens S5 models: the panel and related system hardware.
Related topics
+ 6ES5 816-0AA11 and 6ES5 375-0LC41: separate operating-system and user-memory roles.
+ 6ES5 984-2UA11 and 6ES5 982-3UB11: adapter/power and cabinet-mounting hardware.
+ 6ES5 393-0UA15 OP 393 and 6ES5 395-0UA11 OP 395: other operator panels requiring separately verified application conditions.
Browse SIMATIC S5
Siemens S5 · S5 memory cards · S5 cables · Second-hand Siemens products
Siemens and external references
+ Siemens OP 396 Operating Instructions — EWA 4NEB 810 1288-02a, English. Chapter 2: display, keypad, interfaces, memory and specifications; Chapter 3: commissioning; Chapter 6: functions; Chapter 9: error messages; Chapter 15: order numbers.
+ Siemens SIMATIC S5 technical-document index. Identifies the OP 396 manual reference and Siemens support entry.