6ES5 375-0LC41

Siemens 6ES5 375-0LC41 SIMATIC S5 16 KB EEPROM Memory Submodule

The Siemens 6ES5 375-0LC41 is a 16 KB, byte-organized 375-series EEPROM memory submodule for nonvolatile program storage in SIMATIC S5 systems. Siemens lists this order number for S5-95U, S5-100U and S5-115U CPUs. The S5-100U ordering table rates it at 8,192 STEP 5 statements. Its Siemens PG programming number is 212.

Maintenance teams use the submodule to keep a verified STEP 5 program ready to reload into the CPU. The EEPROM retains its contents with the power off and can be erased and rewritten electrically. The 6ES5 375-0LC31 is the 8 KB EEPROM version. The 6ES5 375-1LA21 also holds 16 KB and uses UV-erasable EPROM technology.

Which CPUs support this submodule?

Siemens S5-95U manuals list the 375-0LC41 as an accessory for the 6ES5 095-8MA04 and 6ES5 095-8MC01. The separate S5-90U ordering table lists 375-8LC memory submodules.

The S5-100U manual lists this EEPROM for CPU 100 (100-8MA02), CPU 102 (102-8MA02) and CPU 103 (103-8MA03). The program being restored must fit in the CPU’s own program memory. The S5-115U manual lists this EEPROM for CPUs 941, 942, 943 and 944. Examples include the CPU 941 (941-7UB11) and CPU 944 (944-7UB11).

The S5-115F manual also lists this EEPROM. On an S5-115F system with a CPU 942F, using EEPROM in safety mode requires explicit approval from the inspector at the individual acceptance test. Subunits A and B must have the same memory configuration and matching memory submodule order numbers.

Backing up and restoring the program

Use programming number 212 when setting up the EEPROM on a Siemens PG. For online backups, select an S5 PG cable that matches the CPU interface. The S5-100U manual requires a connected backup battery when writing to EEPROM from the CPU. Restoring transfers the program from EEPROM to the CPU and can overwrite the program already there.

How do the CP 521 SI and OP 396 use it?

The CP 521 SI (6ES5 521-8MA21) manual lists this submodule as 2 × 8 KB EEPROM. The processor can store interface and driver settings in DB1 and printer message texts in DB2–DB63.

The OP 396 Siemens operator panel can use this submodule to hold a panel project created in COM 396 or a data dump from the panel. Load the contents for the device in which you intend to use the submodule.

Editor’s note

Read the full suffix on a spare before buying it. The 0LC41 and 0LC31 use the same memory technology and have different capacities.

Record the CPU order number and the program size before replacement. If the CPU has changed, check that the saved program fits the replacement CPU’s memory.

Switch off the S5 power supply before removing the submodule. Keep the last working program in a separate STEP 5 project file.

Read back the EEPROM after programming and compare it with the project file. Confirm which machine the stored program belongs to before restoring it.

If a transfer fails, start by checking the transfer direction and the CPU’s memory capacity. When writing from an S5-100U CPU to EEPROM, check the backup battery connection as well.

OtomasyonAVM resources and PDFs

+ Siemens SIMATIC S5 PLC overview

+ SIMATIC S5-115 manuals and PDF archive

Related topics

+ 6ES5 375-0LC31 8 KB EEPROM · 6ES5 375-1LA15 8 KB CMOS EPROM · 6ES5 375-1LA21 16 KB CMOS EPROM

Browse SIMATIC S5

+ SIMATIC S5 memory submodules · SIMATIC S5 · Siemens automation products

Siemens and external references

+ SIMATIC S5-90U/S5-95U System Manual, Appendix E (PDF) · SIMATIC S5-95U Quick Reference, 8MC01 and memory ordering table (DE, PDF)

+ SIMATIC S5-100U System Manual, CPU and EEPROM ordering table (PDF)

+ SIMATIC S5-115U System Manual, Table 2-8 memory submodules (PDF)

+ SIMATIC S5-115F System Manual, Table 2-3 memory submodules (PDF) · Section 10.1, user memory requirements for safety mode (PDF)

+ CP 521 SI Communications Processor Manual, Section 2.10 accessories (PDF) · OP 396 Operator Panel Manual, EEPROM options (PDF)