Toshiba VF-PS1 Fault codes 1
nOFF: Main Circuit Undervoltage
The supply voltage between R, S and T is too low.
There may also be a problem with the current-limiting circuit or the DC circuit fuse.
Solutions:
Measure the main circuit supply voltage. If the supply voltage is within the normal range but the fault remains, the inverter may require repair.
Contact technical service if necessary.
rtry: Retry
The inverter is currently in the restart sequence.
A momentary interruption or temporary stop has occurred.
Solutions:
If the inverter restarts after a few seconds, this is normal operation. Be careful around the machine because the motor and connected equipment may restart automatically.
Err1: Set Point Alarm
The frequency-setting signals at Points 1 and 2 are set too close to each other.
Solution:
Increase the difference between the frequency-setting signals at Points 1 and 2.
Clr: Clear Activation Notification
This message is displayed when the STOP key is pressed while a trip code is being displayed. The RES input signal is open during the trip indication.
Solutions:
Press the STOP key again to clear the trip.
Close the RES signal at the input terminal.
EoFF: Emergency Stop Activation Notification
The operation panel has been used to stop the inverter while it is operating in automatic or remote-control mode.
Solution:
Press the STOP key to execute the emergency stop. Press another key to cancel the emergency-stop command.
HiLd: Setting Error Alarm
An error occurred while reading or writing data. The error code and data are displayed alternately twice.
Solution:
Check the setting and make sure the data has been entered correctly.
OFF: ST Signal Off
The ST terminal, or the terminal assigned to the ST function, is open.
Solution:
Close the ST terminal to the CC circuit.
PrF: PWR Signal Off
The PWR terminal is open.
Solution:
Close the PWR-P24 circuit.
CFF: Control Power Backup Undervoltage Error
The control voltage between the +SU and CC terminals is too low.
Control power is not being supplied through the +SU and CC terminals.
Parameter F647 is not set correctly.
Solutions:
Check whether the voltage between the +SU and CC terminals is 20 VDC or higher.
Set parameter F647 to 0 if the control-power backup device is not being used.
After a CFF error occurs, the inverter will not automatically reset even if the voltage between +SU and CC returns to normal. Turn the inverter off and then back on to reset it.
OC1 - OCP1P: Overcurrent During Acceleration
The acceleration time (ACC) is too short.
The V/f setting is incorrect.
The motor is being restarted shortly after stopping.
A special motor, such as a low-impedance motor, is being used.
The manual torque-boost value (υb) is too high.
Solutions:
Increase the acceleration time (ACC).
Check the V/f parameter settings.
Use the UuS (automatic restart) and UuC (regenerative power transition control) functions.
Increase the carrier frequency (CF).
Reduce the υb setting value.
Reduce the FF setting (stall-prevention level) to 130.
Increase the CF setting if the carrier frequency is 2 kHz or lower.
OC2 - OC2P: Overcurrent During Deceleration
The deceleration time (dEC) is too short.
Solution:
Increase the deceleration time (dEC).
OC3 - OC3P: Overcurrent During Constant-Speed Operation
The load is fluctuating suddenly.
The load or connected machine is operating abnormally.
Solutions:
Reduce load fluctuations.
Check the load and the connected machine.
Toshiba VF-PS1 Fault Codes
• Toshiba VF-PS1 Fault Codes – Main Index
• VF-PS1 Fault Codes 1 – nOFF, rtry, Err1, Clr, EoFF, HiLd, OFF, PrF, CFF, OC1, OC2, OC3
• VF-PS1 Fault Codes 2 – OCA1, OCA2, OCA3, OCL, OCr, OH, OH2, OL1, OL2, OLr
• VF-PS1 Fault Codes 3 – OP1, OP2, OP3, OL, UC, UP1, E, EEP1, EEP2, EEP3, EF1, EPH0
• VF-PS1 Fault Codes 4 – EPH1, Err2, Err3, Err4, Err5, Err6, Err7, Err8, Etn, Etn1, Etn2, Etn3, EtyP, E-10
• VF-PS1 Fault Codes 5 – E-11, E-12, E-13, E-17, E-18, E-19, E-20, E-21, E-22, E-23, E-24, E-25, E-26, E-29, SOUt, PrF
VF-PS1 Technical Pages
• Toshiba VF-PS1 AC Drive Main Page
• Toshiba VF-PS1 User Manual
• Toshiba Drives and Automation Main Page
• AC Drives (VFD) Main Category