VF-PS1 AC DRIVE

Toshiba VF-PS1 AC Drive – Variable Frequency Drive
Hello,
Toshiba VF-PS1 is one of the high-performance industrial drive series developed for demanding motor control applications. Its wide power range, advanced motor control functions and flexible parameter structure make it suitable for pumps, fans and many heavy-duty industrial systems.
Wide power range
The VF-PS1 series is available in a wide range of power ratings. Three-phase 400 V models extend up to 630 kW, while 230 V three-phase versions cover approximately 0.4 to 90 kW.
Motor control functions
VF-PS1 supports V/f scalar control, variable-torque applications, sensorless and closed-loop vector control, and torque limiting. Programmable logic functions and application-oriented control features provide additional flexibility for fan and pump systems.
The drive also provides multiple motor parameter sets, monitoring functions, PID control and support for optional expansion cards. These functions allow one drive platform to be adapted to different motors and process requirements.
Harmonic and EMC solutions
For higher-power installations, DC reactor solutions can be used to reduce harmonic current distortion and improve the electrical characteristics of the drive system. The VF-PS1 series also provides EMC filtering solutions depending on drive size and configuration.
IP54 protection option
IP54 versions are available for selected VF-PS1 configurations, including a range of 400 V models up to approximately 90 kW. The exact enclosure rating should always be checked against the specific VF-PS1 model number and technical documentation.
Easy Key and parameter access
The Easy Key function provides convenient access to selected parameters and helps simplify commissioning and maintenance. The parameter structure also allows frequently used settings and recently modified parameters to be reviewed more efficiently.
Coast stop and programmable terminals
The motor can be configured for a free-run or coast-to-stop operation through the programmable terminal functions. For applications using the ST terminal, settings such as F110 and the ST-CC control logic must be configured according to the required operating sequence.
Because terminal assignments and parameter settings can vary according to the application, the relevant Toshiba VF-PS1 user manual should be checked before commissioning or modifying control-terminal functions.
HI and LO parameter warnings
If HI or LO appears while adjusting a parameter, the requested value may be outside the permitted programming range. A previously changed parameter may also affect the allowable upper or lower limit. In this situation, check both the parameter range and any related settings before changing the value.
Recently changed parameters
VF-PS1 includes a function for displaying recently modified parameters in reverse chronological order. This is particularly useful during commissioning, maintenance or when several drives are being configured with similar settings.
Local / Remote control
The VF-PS1 can be controlled locally from the keypad or remotely through terminals and external control systems. Local/Remote switching provides convenient access during commissioning and maintenance, while the bumpless transfer function can help maintain a smoother transition between control modes when correctly configured.
Fire and emergency operation
VF-PS1 provides a forced-operation function that can be configured for certain fire or emergency operating scenarios. The exact behaviour depends on the selected parameters, control logic and protection conditions.
This function must be configured according to the machine or building safety requirements and should not be treated as a replacement for the required safety system.
Multi-PID function
The integrated PID control functions can be used to regulate process variables such as pressure, flow and temperature. This makes the VF-PS1 especially useful in pump, fan and process-control applications.
Sleep function – automatic stop
In pump and fan applications, the sleep function can stop the motor automatically when demand falls below a defined operating level and restart it when required. This can provide additional energy savings in variable-demand systems.
Low-torque detection
Low-torque detection can be used to identify abnormal reductions in motor load. Typical examples include loss of pump load or a broken belt in fan and AHU applications.
PTC thermistor input
A motor PTC thermistor signal can be used for motor temperature protection. This allows the drive to respond to an overheating condition detected directly from the motor.
VF-PS1 fault codes and technical documentation
For troubleshooting, the VF-PS1 section includes dedicated information for OC1, OC2, OC3, OH, OL1, OL2, OP1, OP2, OP3, EPH0, EPH1, Err-series and many other alarm, warning and trip messages.
• Toshiba VF-PS1 Fault Codes and Troubleshooting
Refine Search
Toshiba drive - VFPS1-4550PL - 55KW -380V
380 Volt - 55 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 55 kw Output Current: 11..
248.00USD Ex Tax: 248.00USD
Toshiba VFPS1-4185PL (18.5KW -380V)
380 Volt - 18.5 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 18.5 kw Output Current: ..
243.00USD Ex Tax: 243.00USD
VFPS1-4110KPC - 110KW -380V
380 Volt - 110 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 110 kw Output Current: 215&nb..
251.00USD Ex Tax: 251.00USD
VFPS1-4132KPC - 132KW -380V
380 Volt - 132 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 132 kw Output Current: ..
262.00USD Ex Tax: 262.00USD
VFPS1-4220PL - 22KW -380V
380 Volt - 22 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 22 kw Output Current: 48..
244.00USD Ex Tax: 244.00USD
VFPS1-4300PL - 30KW -380V
380 Volt - 30 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 30 kw Output Current: 66..
245.00USD Ex Tax: 245.00USD
VFPS1-4370PL- 37KW -380V
380 Volt - 37 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 37 kw Output Current: 79 ..
246.00USD Ex Tax: 246.00USD
VFPS1-4450PL - 45KW -380V
380 Volt - 45 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 45 kw Output Current: 94..
247.00USD Ex Tax: 247.00USD
VFPS1-4750PL - 75KW -380V
380 Volt - 75 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 75 kw Output Current:&nb..
249.00USD Ex Tax: 249.00USD
VFPS1-4900PC - 90KW -380V
380 Volt - 90 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 90 kw Output Current: 17..
250.00USD Ex Tax: 250.00USD
Toshiba drive - VFPS1-4037PL - 4KW -380V
380 Volt - 4 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 4 kw Output Current: 9.5 ..
238.00USD Ex Tax: 238.00USD
VFPS1-4007PL - 0.75KW -380V
380 Volt - 0.75 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 0.75 kw Output Current: ..
233.00USD Ex Tax: 233.00USD
VFPS1-4015PL - 1.5KW -380V
380 Volt - 1.5 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 1.5 kw Output Current: ..
236.00USD Ex Tax: 236.00USD
VFPS1-4022PL - 2.2KW -380V
380 Volt - 2.2 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 2.2 kw Output Current: ..
237.00USD Ex Tax: 237.00USD
VFPS1-4055PL - 5.5KW -380V
380 Volt - 5.5 kw TOSHIBA VFD Power source: 380 Volt AC Output Power : 5.5 kw Output Current: ..