6ES5 700-0LA12
Siemens 6ES5 700-0LA12 SIMATIC S5 CR 700-0LA central rack
The 6ES5 700-0LA12 is the compact CR 700-0LA central rack for SIMATIC S5-115U. It has dedicated PS and CPU positions, four I/O positions numbered 0–3 and a separate IM slot. Siemens ST 50 lists the PS 951 power supply and CPUs 941 through 945. For a CPU 944 or CPU 945, check the full CPU order number and the layout in its manual.
Slot layout and mounting
The rack measures 353 × 303 × 47 mm (W × H × D) and weighs approximately 4 kg. These figures are for the rack itself. Allow cabinet depth for the modules, front connectors and cable bends.
Use Figure 3-2 to check the slot assignments for digital inputs, digital outputs, combined digital I/O and analog I/O. For ES 902-design digital or analog modules from the S5-135/155U family, the drawing specifies slot 0 and an adapter casing. Communications module placement also depends on the model. For example, Figure 3-2 shows the CP 523 in slot 0 with an adapter casing.
Centralized expansion and termination
The IM 305 and IM 306 provide centralized expansion options. ST 50 lists up to three expansion units for the applicable configuration. Check the actual limit for the chosen interface module and connecting cable. Match expansion racks such as the ER 701-0 and ER 701-1 to their own slot drawings. When neither IM 305 nor IM 306 is fitted, Siemens specifies that the terminating connector stays in place.
The 6ES5 700-0LB11 also belongs to the CR 700-0 family. That variant accommodates up to six I/O modules using adapter casings in positions 0 and 3. Both racks have the same external dimensions, so use the full order number on the label. The CR 700-1, CR 700-2 and CR 700-3 are larger central racks. The ER 701-2 belongs to the expansion rack group. Compare the full order number, PS and CPU positions, and IM layout with the cabinet drawing before ordering a spare.
1. Record the layout before removal. Have qualified personnel isolate cabinet and field supplies and verify that power is off. Photograph the PS, CPU and IM labels, cards in positions 0–3 and their numbered front connectors.
2. Check the terminator when there is no expansion interface. For a rack without IM 305 or IM 306, verify the connector position against Figure 3-2. Record it as a part to transfer when replacing the rack.
3. If local I/O works and expansion fails, trace the link. Check the central IM, both cable ends and the expansion-side interface in order. Identify where the failure begins before ordering a rack.
4. For a single-slot fault, check both the card code and address. Compare the front connector and field circuit with the drawing. For adapter-mounted cards, record the slot 0 requirement where applicable and the address used in the project.
5. Inspect the backplane before buying used. Ask for close-up photos of the 0LA12 label, PS/CPU/IM sockets and connectors 0–3. Ask which CPU and slots were tested and whether the terminator is included.
To offer a rack for sale, send its full part number, quantity, condition, label and connector photos, and asking price to otomasyonavm@gmail.com.
Siemens PDF documentation
S5-115U Figure 3-2, exact rack layout (EN) · S5-115U technical table, p. 15-5 (EN) · ST 50, CR 700-0LA, p. 3/58 (EN) · OtomasyonAVM S5-115 PDF archive
Related topics
Siemens S5 PLC overview · SIMATIC S5 CPU models · IM 306 interface
Second-hand Siemens navigation
SIMATIC S5 racks · SIMATIC S5 · Siemens S5 PLC · Second-hand Siemens