Siemens 6ES5 701-2LA12 ER 701-2 expansion rack

The Siemens 6ES5 701-2LA12 is the ER 701-2 mounting rack for building an EU 2 expansion unit in SIMATIC S5-115U and S5-115F systems. The S5 CPU range covers the processors used in the central controller. For example, the 6ES5 700-2LA12 CR 700-2 houses central-controller hardware. The ER 701-2 houses additional I/O modules.

Slots and interface configuration

In a distributed S5-115U layout, slots 0–6 are assigned to I/O and slot 7 to the link interface. This leaves seven positions for suitable I/O modules. Check the full order number and permitted position for each digital input, digital output, combined digital I/O or analog I/O module. Compact and block-type modules follow different slot rules.

For S5-115U, Siemens catalog ST 50 shows a PS 951 in the PS position and an IM 306 in the IM position to set addresses for block-type I/O. Match the installed S5 power supply and IM 306 module to the cabinet layout. The catalog lists IM 314, IM 317 and IM 318 as distributed interface options.

In an IM 314 installation, the IM 304 goes on the central side and the IM 314 on the expansion side. Check the parts list for the 6ES5 491-0LA12 adapter casing, 6ES5 760-1AA11 termination plug and the correct S5 interconnecting cable.

For S5-115F, ST 50 shows IM 306 for a centralized link, with the ER 701-2 PS position left empty. In the distributed layout, IM 314 takes slot 7 and the rack requires a power supply. IM 306 is still required for address setting.

The maximum of eight in the S5-115U manual is the rack specification. The distributed layout reserves one of those positions for the interface. The rack does not process I/O interrupts. It measures 483 × 303 × 47 mm (W × H × D) and weighs 5 kg.

What to inspect on a used rack

Ask for a photo of the label showing the 2LA12 suffix and close-ups of the PS and IM positions and slot 7. The ER 701-2 2LA11 has a different order number. Consult the individual slot charts for the ER 701-3 3LA13 and ER 701-1 1LA12. The CR 700-2F 2LA22 is a central rack. If you are replacing cabinet hardware, check whether the mounting accessories with cable duct are included.

If the entire expansion unit is unreachable, start with the power supply status and the link between the interface modules. If the issue affects one card, isolate power and inspect the backplane connector, module seating and address settings for that slot.

Editor’s note
Ask for separate photos of the backplane and slot 7. A rack can look sound from the front and still have bent backplane pins. Confirm separately whether the power supply, interface, cable and termination plug come with the rack.