6ES5 491-0LB11
Siemens 6ES5 491-0LB11 — S5-115U/F adapter casing for up to two boards
Siemens 6ES5 491-0LB11 is an adapter casing for up to two suitable ES 902 boards in S5-115U/F systems. The manufacturer data sheet describes adapting S5-135U/155U-type boards to this construction. In Siemens S5 and SIMATIC S5 maintenance, record the casing number separately from the electronic module installed inside.
The casing guides and secures the board assembly for installation in an S5 rack. It is a mechanical adaptation component within the S5 expansion-product range. For a used assembly, establish whether the offer includes the casing alone or a complete set with the internal boards.
Dimensions and board capacity
Siemens ST 50 specifies a single-width casing accommodating up to two compact boards. Dimensions are 43 × 303 × 187 mm (W × H × D), with an approximate weight of 0.45 kg. The catalog ordering description includes one protective cover.
Two-board capacity does not mean that any two functional modules can be combined. One functional module may already consist of two boards; the module and rack documents determine the permitted arrangement. The wider 6ES5 491-0LD11 accommodates four boards and the 6ES5 491-0LC11 six. Do not apply their dimensions to the 0LB11.
Rack and slot compatibility
The S5-115U manual shows that two-board installation conditions differ between CR 700-0 versions. Assess 6ES5 700-0LA12 and 6ES5 700-0LB11 using their respective layout diagrams. The manual specifically permits two-board adapter arrangements in the 0LB11 rack version.
The catalog also lists the CR 700-1, CR 700-2 and CR 700-3 families. For a CR 700-1, CR 700-2 or CR 700-3, verify the intended slot against the complete internal-module number. Physical fit alone does not establish that a slot supports the module.
For ER 701-2 and ER 701-3 expansion racks, assess the casing, module and system connection together. The maximum board count alone does not establish slot permission, addressability or adequate power.
Installation, guides and retention
The manufacturer describes sliding the board along the casing guides and securing it with the eccentric lock at the top. When fitting S5 modules, inspect the guides, casing alignment and locking mechanism. Do not force the board into place; check the rear-connector alignment.
The internal interface board, communications processor or function module retains its own installation and connection requirements. Work with system power disconnected and use appropriate ESD handling for the electronics. Check that the protective cover and retaining components are present.
Power, addressing and functional checks
Electrical loading, addressing and cooling requirements depend on the electronic module inside. Check S5 power-supply capacity and the installed system’s airflow. Slot and power requirements for a CP 525, for example, cannot be determined from the casing number alone.
The casing label does not identify the internal module’s channel count or communications protocol. Record the casing number, internal-board order number, rack/slot and completed checks separately. After mechanical inspection, verify the electronic module using its own functional test procedure.
Editor’s note
When buying a used Siemens assembly, the visible label may identify only the casing. Request the internal-board label as well. Establish exactly what is included before assessing the offer.
Inspect the internal guides and top lock closely. A loose board or one that needs force to seat is a meaningful defect. A distorted casing can also stress the rear connector of a healthy module.
Discuss missing covers, locks or retaining parts before purchasing. Ask for front, rear and internal photographs rather than relying on one exterior image.
Do not install two arbitrary boards merely because the casing holds two. Some modules already form a two-board set. Check the documented arrangement for the intended rack and slot.
Record correct mechanical seating and successful electronic operation as separate checks. A closing cover does not establish a sound connection. Verify the intended retention arrangement without forcing the board.
For legacy S5 systems, photograph the complete assembly before removal. Keep the rack number, slot, casing label and internal-board number in one maintenance record. That gives the next technician reliable information.
OtomasyonAVM resources and PDFs
+ Siemens S5 PDF archive: system and installation documents. Manufacturer data-sheet and catalog references are below.
+ 6ES5 491-0LB11 model page and used Siemens S5 models: the casing and related system hardware.
Related topics
+ 6ES5 491-0LD11 and 6ES5 491-0LC11: adapter casings with different widths and capacities.
+ 6ES5 700-0LA12 and 6ES5 700-0LB11: CR 700-0 versions requiring separate layout checks.
+ S5 rack types and S5 interface modules: matching the casing, slot and internal module.
Browse SIMATIC S5
Siemens S5 · S5 racks · S5 expansion products · Second-hand Siemens products
Siemens and external references
+ Siemens 6ES5491-0LB11 data sheet — manufacturer document hosted by EU Automation. S5-115U/F, ES 902 construction and capacity for up to two boards.
+ Siemens ST 50 — SIMATIC S5 catalog, English. Page 3/98: 0LB11/0LD11/0LC11 capacities, dimensions and weights; approximately 0.45 kg for the 0LB11.
+ Siemens S5-115U A-CPU Handbuch — GWA 4NEB 811 6000-01b, German. Chapter 3: rack layouts and fitting a board into the adapter casing.