Siemens 6ES5 752-0AA12 — 20 mA TTY Serial Interface Submodule
The Siemens 6ES5 752-0AA12 is a 20 mA current-loop TTY serial interface submodule for SIMATIC S5 systems. This S5 interface submodule fits suitable host devices such as the CP 524 and CPU 928B. It has a 25-pin female D-sub connector and a documented maximum transmission rate of 9600 bit/s.
Separate current loops are used for transmitting and receiving. With normal TTY signalling, approximately 20 mA represents logic 1 and interrupted current represents logic 0. The CPU 948 is also listed by Siemens for use with the TTY submodule. Assess the application together with the S5 communication hardware and the partner device’s interface.
TTY interface and communication function
Communication using RK 512, 3964/3964R or the open driver is managed through the host CPU/CP’s software and parameters. When reviewing different CP 524 hardware versions, check the submodule, driver and cable together. In PLC programming, matching communication settings matters as much as selecting the correct physical interface.
Siemens provides TTY cable examples between a CPU and CP 524, CP 525 or other suitable communication partners. When selecting an S5 connecting cable, assess the transmit/receive connections, current-feed jumpers and the partner device’s active/passive circuitry together.
Main connections on the 25-pin connector
Pin 10 = +TxD, pin 19 = −TxD; pin 13 = +RxD, pin 14 = −RxD. Current-source connections are 12 = transmitter +20 mA and 16 = receiver +20 mA; current returns are pins 21 and 24. Pin 1 is the shield and pin 9 is the external 24 V connection.
This pin list is not a complete cable circuit. Each transmit and receive loop must include the partner device’s connections and the required cable jumpers. Figures 5-20 and 5-22 in the manufacturer’s manual show current direction and standard wiring.
Current supply and J1/J2/J3 jumpers
Loop current can be supplied by the submodule or the communication partner. Establish which side supplies each transmit/receive loop. The isolation arrangement of the current-supplying side must not be assumed to be the same as that of the passive side.
J1 and J2 select normal or inverted transmit and receive data polarity. J3 selects whether the 24 V used to generate loop current comes internally through the backplane connector or externally through D-sub pin 9. Match the jumpers to the manufacturer’s diagrams and the existing installation.
The manual specifies a maximum TTY cable length of 1000 m using a shielded line. Review the line arrangement, current source, connector housings and grounding together. Correct shield and metal-housing connections matter for noise immunity.
Differences from other 752 submodules
The 6ES5 752-0AA22 and 6ES5 752-0AA23 are V.24/V.28 — RS-232C interface options. The 6ES5 752-0AA43 provides RS-422/RS-485. A similar connector or shared 752 family designation does not make these direct equivalents for a TTY connection.
The 6ES5 752-0AA53 PG submodule and 6ES5 752-0AA62 SINEC L1 submodule are listed for different functions. Interfaces that use current-loop signalling do not necessarily provide identical communication functions or parameter settings.
Installation and fault finding
Install or remove the submodule with the PLC power supply switched off. Check that it is fully seated and correctly secured. During PLC debugging, review the host CPU/CP settings, partner baud rate and data format, both current loops and the cable connections together.
Editor’s note
Start by checking that the label really says 752-0AA12. Treating a similar-looking RS-232 card as a TTY interface can send the checks in the wrong direction. A photograph of the old module and cable connections is a useful starting point.
If there is no communication, give the current supply a fair check before condemning the card. Establish which side supplies the loop current. Two serviceable devices will still fail to exchange data if both are waiting for current from the other side.
If communication works in only one direction, inspect the two loops separately. Check Tx, Rx and the current-return paths. That gives you a clearer sequence than changing several parameters at once.
On a used card, pay particular attention to J1, J2 and J3. They may have been changed for the previous installation. Record the existing settings before moving them, so you keep the evidence that can help explain the fault.
Where possible, bench-test with a known serviceable cable and a suitable host device, and confirm data transfer in both directions. Review the S5 system information and installed SIMATIC S5 hardware together to separate module, cable and configuration problems.
OtomasyonAVM resources and PDFs
+ Browse S5 interface modules, S5 communication modules and S5 cables and connectors to review the related parts together.
+ The OtomasyonAVM S5 PDF archive is the starting point for our manual resources. Technical details for this submodule appear in the S5-135U/155U System Manual, Section 5.11.4: printed pages 5-106–5-111, with common specifications on 5-122. The documents below are in English.
Related topics
+ 6ES5 524-3UA15 — CP 524 · 6ES5 928-3UB21 — CPU 928B · 6ES5 948-3UA13 — CPU 948.
+ 6ES5 752-0AA23 — V.24/RS-232C · 6ES5 752-0AA43 — RS-422/RS-485 · 6ES5 752-0AA53 — PG submodule.
Browse SIMATIC S5
+ S5 interface modules · S5 communication modules · SIMATIC S5 systems.
+ Siemens S5 main page · Used Siemens automation equipment.
Siemens and external references
+ Siemens S5-135U/155U System Manual — C79000-G8576-C199-07, English: TTY applications, 25-pin assignments, J1/J2/J3 jumpers, cables and specifications.
+ Siemens TTY submodule manual section — English, archived by SPS-Service: a six-page extract containing printed pages 5-106–5-111 from the same manufacturer’s manual.
+ Siemens ST 50, 1998 catalog — archived English copy: 752 submodule ordering tables for CPU 928B, CPU 948 and CP 524.