6ES5 928-3UB21

Siemens 6ES5 928-3UB21 – CPU 928B, 64 KB user RAM, single-slot design

Siemens 6ES5 928-3UB21 is a CPU 928B central processing unit in the SIMATIC S5 family. It operates in an S5-135U/155U central rack and provides 64 KB internal user RAM, separate DB RAM, a fixed PG interface and an optional second serial interface. This Siemens S5 version occupies one slot.

Compared with 6ES5 928-3UB12, integrated RAM, Flash memory-card operation and single-slot construction are significant changes. Replacement of a 6ES5 928-3UA21 CPU 928A also requires review of the program, instructions and communications. Similar order numbers do not establish identical application behaviour.

User RAM, DB RAM and Flash card

The 64 KB user RAM stores code and data blocks; DB RAM is a separate data area. Do not combine these into a single contiguous program-memory figure. When selecting an S5 memory card, verify its complete code and the capacity usable by the CPU. Siemens ST 50 lists the 374-2KG21 with 128 KB physical capacity and 64 KB usable for this CPU.

When backing up the STEP 5 application, preserve DB/DX contents and relevant system parameters as well as code blocks. Use suitable programming software to compare the running RAM contents with the Flash card. A fitted card does not establish that the latest plant modification has been saved there.

SI1 programmer interface and optional SI2

SI1 is a 15-pin PG interface. The system manual specifies 9600 bit/s for the PG connection. Match both connector and electrical interface when choosing an S5 programming cable. The CPU front connector and access through a 923C coordinator use the same SI1; they cannot operate simultaneously as independent PG connections.

SI2 functionality depends on the fitted interface submodule. Select a suitable S5 interface submodule; a second PG/OP connection requires a PG submodule. The 6ES5 752-0AA53 PG submodule is the relevant option. An empty SI2 receptacle is not an operational port; keep its cover fitted when unused.

Appropriate hardware and parameters support RK 512, 3964/3964R, open driver and SINEC L1. When reviewing S5 communications, check the electrical interface separately from the protocol. For the listed communication functions, the manual specifies RS422-A mode when using an RS422-A/485 submodule.

Program execution and I/O

The CPU supports cyclic, time-controlled and interrupt-driven execution. Its technical table lists 256 timers and 256 counters. Process-image capacity is 1024 digital inputs and 1024 digital outputs; these figures do not describe the entire peripheral address space.

Compare digital input and digital output module addresses with the existing program and rack arrangement. In a multiprocessor installation, record which CPU controls each peripheral group. Do not reconstruct the program address list from physical module position alone.

Supply, dimensions and installation

The system manual specifies 5 V DC ±5% and 24 V DC +25%/−17% supply rails, with 0.5 A typical consumption at 5 V. Assess the S5 power supply against all installed modules. These figures describe CPU power supplied through the rack arrangement.

Dimensions are 20.32 × 233.4 × 160 mm (W × H × D), weight approximately 0.6 kg and protection IP00. When reviewing the S5 rack layout, include a blanking plate for any slot released when replacing a double-width CPU with this version.

Diagnostics, revisions and used-unit checks

QVZ relates to missing peripheral acknowledgement, ADF to addressing, ZYK to cycle monitoring and BASP to output inhibition. During PLC troubleshooting, record LED states together with CPU diagnostics. An SI2 fault also requires checking the submodule type and parameters.

For a used PLC CPU, inspect the complete label, hardware version, memory card and SI2 submodule. With used Siemens equipment, verify program transfer and required communication functions as well as the RUN indication.

Base model and revision comparisons on the existing project. For modernization, assess Derell PLC options as a separate engineering project, mapping memory use, interrupts, I/O structure and communications to the proposed system.

Editor's Note

Photograph the complete 3UB21 code, hardware revision and fitted SI2 submodule first. The shared 928B name does not make every detail identical to an earlier unit. Check the single-slot construction too.

Back up the running program, data blocks and system parameters together. A Flash card may hold an older application. Compare it with the latest RAM contents before removing the CPU.

If PG access fails, check the cable, interface and any coordinator connection before rejecting the CPU. Establish whether the submodule required for the second port is actually installed.

Treat the RUN indication as the start of the test. Check PG access, the correct program, required I/O and communications together. Keep the SI2 receptacle covered when unused and close any released rack slot.

Do not use OVERALL RESET merely to clear an indication. It erases RAM areas. Have diagnostics, backups and a recovery source ready first, and inspect the battery and rack supply arrangement.

OtomasyonAVM resources and PDF archive

6ES5 928-3UB21 main page · Used Siemens S5 models · Siemens S5 PDF archive

The main reference is the exact CPU 928B -3UB21 section 5.3 of the S5-135U/155U System Manual, C79000-G8576-C199-07. The CPU 928B-3UB21 Programming Guide, C79000-G8576-C870-01 and Siemens ST 50 were also consulted. These documents are in English.

Related topics

6ES5 928-3UB12 · 6ES5 928-3UA21 · 6ES5 752-0AA53 · Derell PLC options

Navigation

SIMATIC S5 · Used Siemens · S5 memory cards · S5 interfaces · S5 racks

Siemens and external references

Siemens CPU 928B -3UB21 hardware description, printed 5-30 · RAM, DB RAM and interfaces, printed 5-31–5-32

Electrical and mechanical specifications, printed 5-40–5-41 · CPU 928B-3UB21 Programming Guide – version differences and programming