Siemens 6ES5 464-8MF21 — Two-Input Pt100 Analog Module with Linearization
The Siemens 6ES5 464-8MF21 is a two-input analog module with selectable internal Pt100 linearization for SIMATIC S5. It is used with S5-90U, S5-95U and S5-100U controllers and ET 100U/ET 200U stations. Within the S5 analog module range, its key feature is switchable Pt100 linearization. The voltage input range is ±500 mV; either one or two channels can be enabled.
The module acquires readings from Pt100 resistance thermometers for the PLC. Typical applications include monitoring tank, mould and machine temperatures using temperature sensors. The PLC program uses the analog input reading to perform the control function.
Pt100 measurement and linearization
With Pt100 linearization enabled, the nominal temperature range is −100 to +850 °C with a resolution of 0.5 °C per measurement unit. Resistance/voltage data requires different interpretation when linearization is disabled. Check how the analog signal is represented before applying any scaling.
The nominal resistance range for Pt100 measurement is 0–200 Ω, with an upper measuring limit of 400 Ω; these resistance figures are distinct from the temperature range. Input resistance is 10 MΩ. Consider the difference between Pt100 and thermocouples when selecting a sensor. A Pt1000 must not be assumed compatible with the Pt100 setting.
Four-wire connection and terminals
For four-wire resistance measurement, channel 0 uses 3 M+ / 4 M− for sensing and 7 IC+ / 8 IC− for excitation. Channel 1 uses 5 M+ / 6 M− for sensing and 9 IC+ / 10 IC− for excitation. The Pt100 excitation current is 2.5 mA.
A two-wire connection adds lead resistance to the reading; a correctly wired four-wire circuit reduces this effect. Check the S5 wiring and connections, sensor leads and temperature sensor accessories together. Siemens specifies a maximum 200 m shielded cable length.
The inputs are galvanically isolated from ground, but the channels are not isolated from each other. The permitted potential difference between inputs is ±1 V maximum. Observe this limit when sensors are located at different ground potentials.
Operating settings and PLC data
The front operating mode switch selects line frequency, one or two channels, wire-break indication and Pt100 linearization. Integration time is 20 ms at 50 Hz or approximately 16.6 ms at 60 Hz. When replacing a module in the S5 I/O group, compare these settings with the original.
Input data uses 12 bits plus sign, left-justified two’s complement. With linearization enabled, 0 °C corresponds to 0 measurement units and 100 °C to 200 units. These units are distinct from the raw input word, which also contains status information. Check the data format, sign and scaling together in the PLC program.
The 6ES5 464-8MF11 also belongs to the Pt100/±500 mV group, but the 8MF21 adds selectable internal linearization. Before choosing a replacement, establish whether the application expects temperature data or a resistance-related value.
Power and wire-break diagnostics
The electronics operate from the system’s internal 9 V bus supply; no separate L+ field supply is required. Specified linearization error within the nominal range is ±0.5 °C. This figure alone does not describe the total error of the sensor, wiring and module together.
With wire-break indication enabled, a break in the sensor or its wiring lights the red LED and sets the affected channel’s F fault bit. During PLC troubleshooting, inspect status information alongside the reading. Test-current pulses can cause apparent fluctuations on a digital voltmeter; disabling the indication does not remove those pulses.
Differences from other analog inputs
The 6ES5 464-8MC11 accepts ±10 V, the 6ES5 464-8ME11 accepts 4–20 mA and the 6ES5 466-8MC11 accepts 0–10 V. Their measurement duties differ. A Pt100 replacement must match both the input circuit and the existing program.
Editor’s note
Start by taking a clear look at the label: the 8MF21 suffix matters. When buying a used analog module, ask for a photograph of the operating switches as well as the front label. Having that information to hand makes the replacement much easier.
If the displayed temperature is wrong, give the settings a check before condemning the card. Compare the linearization switch with the value expected by the program. If a Pt100 signal converter is fitted, read its output specification too: a 4–20 mA output needs a different input arrangement from a directly connected Pt100.
For a bench check, use a suitable reference resistor or Pt100 simulator with the correct wiring. 100 Ω represents 0 °C for a Pt100. Test both channels and more than one point. A correct reading at one point is a useful start, but it does not establish accuracy across the whole range.
If the wire-break light is on, work through the sensor, cable joints and terminals in order. Change one thing at a time. This makes it much easier to separate a sensor problem from a cable or channel problem.
Photograph the wiring and switch positions before removing the original. After fitting the replacement, verify both channel readings and the wire-break response under controlled conditions. A short record now will help you, and the next technician, when the machine needs attention again.
OtomasyonAVM resources and PDFs
+ About Siemens S5 PLCs and S5 analog modules: our system overview and module group pages.
+ Siemens S5 PDF files: our archive of S5 system manuals and technical documents. Relevant sections of the English S5-100U and S5-90U/S5-95U manuals are linked in the manufacturer references below.
Related topics
+ 6ES5 464-8MF11 — another Pt100/±500 mV input version; check the linearization difference.
+ What is Pt100? and Pt100 versus thermocouples — measurement principles and sensor selection.
Browse SIMATIC S5
+ S5 analog modules · S5 I/O module group · SIMATIC S5 · Siemens second-hand equipment
Siemens and external references
+ Siemens S5-100U System Manual, English — 14-52/14-53: exact 8MF21 wiring and specifications
+ Same manual, English — 11-13, Table 11-9: linearized temperature values
+ Siemens ET 100U Manual, English — 6-12: Pt100 linearization and 0.5 °C resolution
+ Siemens ET 200U Manual, German — Chapter 7: 464-8MF21 analog value processing