6ES5 526-3LG11
The Siemens 6ES5 526-3LG11 is a CP 526 communications processor for operator displays and process monitoring in SIMATIC S5 systems. This order number identifies the self-ventilated basic board for colour monitors in S5-DOS. The CP 526 family displays PLC process information and lets operators call up screens or enter setpoints from a process keyboard.
This S5 communications board works with a separate monitor and keyboard to form the operator station. When replacing the board, check the monitor signal, display project and rack ventilation together.
Colour monitor wiring and sync
Siemens shows four coaxial video outputs marked R, G, B and S in the CP 526 colour board diagram. The manual describes separate sync and sync carried on the green channel. When selecting a monitor cable, check the sync type accepted by the monitor and the setting on the installed board.
COM GRAPH and the display project
Siemens documents COM GRAPH under S5-DOS as the CP 526 configuration environment. Process screens and their application data can reside in the board’s EPROM or RAM memory submodule. When making a service backup, save the display project and the STEP 5 controller program separately.
Rack, power supply and expansion board
The CP 526 family manual covers the S5-115U, S5-135U, S5-150U and S5-155U. Before installation, check the rack and power supply order numbers. The S5-115U manual excludes the CP 526 from use with the 3 A 7LB14 and 7NB13 supplies because of the DSI signal requirement.
The 6ES5 526-3LA21 and 6ES5 526-3LA22 are separate expansion boards. Siemens describes features such as curves and bar graphs with the expansion board and specifies a ventilated colour basic board for that configuration. If the existing project uses an expansion board, verify the exact basic board and ventilation arrangement.
Identifying the 3LG11 among related order numbers
The 6ES5 526-3LG01 is the self-ventilated monochrome version. The 6ES5 526-3LF11 is listed as a colour basic board with separate ventilation. The 6ES5 526-3LA11 is also a colour version in the forced-ventilation class.
Editor’s note
Photograph the front panel and full order number. Make sure the service record shows the 3LG11 suffix and the positions of the monitor connections.
Record the monitor model and sync arrangement. If the picture rolls or the colours are wrong, check the coaxial leads and monitor setting before replacing the board.
Find where the display project is stored. Put the fitted memory submodule’s order number and the available COM GRAPH backup on the work order. This identifies the project you expect to see when the replacement starts up.
Check the picture and live data separately. If a screen appears but its values stay static, check the CP operating mode and its data exchange with the controller.
Ask what the spare was tested for. When buying a used communications board, ask whether the colour video output and PLC data exchange were tested and whether the memory submodule is included.
OtomasyonAVM references and PDF archive
Browse the Siemens S5 PLC section for model pages and the OtomasyonAVM S5 PDF page for published series manuals. The Siemens CP 526 manual covering video, memory and expansion is linked below.
Related topics
See our PLC and HMI section for operator interfaces and our PLC CPU guide for the controller side of the system.
Site navigation
Siemens Automation › Siemens S5 PLC › S5 communications modules
External references
Siemens COROS CP 526/CP 527 manual (English PDF) · Family-level monitor connections, COM GRAPH and expansion board information.
Siemens S5-115U system manual (English PDF) · PS 951 power supplies and DSI restrictions.
SIMATIC S5 parts list (PDF) · The 6ES5526-3LG11 entry identifies the colour-monitor version, S5-DOS and ventilation class.