6ES5 948-3UA23
Siemens 6ES5 948-3UA23 — S5-155U CPU 948-2 with 1664 KB RAM
Siemens 6ES5 948-3UA23 is the S5-155U CPU 948-2 central processing unit in the Siemens S5 family. It has 1664 KB of internal user RAM. In a SIMATIC S5 installation, it executes the machine program, evaluates inputs, processes control logic and generates output commands.
This order number is the single-slot version described in the system manual’s CPU 948B section. Dimensions are 20.32 × 233.4 × 160 mm, weight is approximately 0.6 kg, and protection is IP00. Do not use the older, double-slot CPU 948 dimensions when checking the rack layout.
Power requirements and related CPU numbers
The manual specifies 5 V ±5% and 24 V +25%/−17% supply rails, with 1.5 A typical consumption at 5 V. This is not the total rack current. Assess the S5 power supply against the combined load of the CPU, modules and installed accessories.
The 6ES5 948-3UA13 is the 640 KB CPU 948-1 version. When comparing with 6ES5 948-3UA21 or 6ES5 948-3UA22, consider more than RAM capacity. Record the full order number, hardware version, physical arrangement and requirements of the existing project separately.
Memory, program and execution time
A 374 Flash EPROM card can provide external storage. When selecting S5 memory products, compare card capacity with the actual program size. The presence of a card such as the 6ES5 374-2FH21 does not establish that it can hold the CPU’s complete program.
The CPU 948 programming guide gives a typical 0.18 µs instruction time for bit operations using F/I/Q operands; this is not the complete program scan time. Resources include 256 timers, 256 counters, 2048 flag bits and 32768 S flags. Assess the STEP 5 program, whether viewed in Ladder or function block representation, alongside actual scan and communication loads.
PG connection and second serial interface
The integrated SI1 is a 15-pin TTY/PG interface, with a specified PG rate of 9600 bit/s. Use the appropriate S5 programming cable. Connector shape alone is not a reason to select an RS-232 cable.
The second interface, SI2, depends on the installed interface submodule. For example, the 6ES5 752-0AA53 PG submodule and 6ES5 752-0AA22 V.24 submodule serve different connection roles. PG, RK 512, 3964/3964R, open-driver and SINEC L1 options require suitable hardware and parameters. Check separately whether the interface submodule is included with a used CPU.
Addressing, multiprocessor operation and diagnostics
The CPU supports single and multiprocessor operation; multiprocessor operation requires a coordinator. In a system using the 6ES5 923-3UC11 COR C, check CPU task allocation and bus access against the existing project. Do not treat a CPU slot number as a digital input, digital output or analog module address.
OVERALL RESET deletes user memory and operand areas. During troubleshooting, do not use it as a trial step before securing the program backup and recovery method. Record the LED pattern, PG diagnostics and conditions under which the fault occurred first.
Editor’s note
When buying a used Siemens CPU, make sure the label clearly reads 3UA23. A general “CPU 948” description is insufficient. Request photographs of the front panel, memory-card receptacle and rear bus connector as well.
A lit RUN indicator does not establish a complete test. PG connection, program loading, memory checks and controlled operation on a suitable bench should be demonstrated separately. Do not assume an untested function is serviceable.
Back up the existing machine CPU’s program and parameters before replacement, and check that the backup files open. Changing a board may be straightforward; reconstructing a missing machine program may take much more work.
Do not overlook the small interface submodule in the SI2 receptacle. Record its full number and compare it with the replacement’s delivery scope. A CPU with an empty receptacle is not the same package as a complete communication assembly.
Do not reach for reset simply because STOP is indicated. Record whether the LEDs are steady or flashing, then examine the supply, connections and project information. In particular, understand what OVERALL RESET erases before using it.
In S5 maintenance, a clear record makes later fault-finding easier. Keep the CPU number, hardware version, memory and SI2 submodule on the same form. Record test duration and functions checked, and distinguish completed tests from checks that were not performed.
OtomasyonAVM resources and PDFs
+ Siemens S5 PDF archive: system, CPU and connection documents. Manufacturer manuals for the CPU 948 are listed under external references below.
+ 6ES5 948-3UA23 model page and second-hand Siemens S5 models: the CPU and related system components.
Related topics
+ 6ES5 948-3UA13 · 6ES5 948-3UA21 · 6ES5 948-3UA22: different order numbers in the CPU family; direct interchangeability should not be assumed.
+ COR C coordinator · S5 memory products · S5 interface modules: other system components.
Browse SIMATIC S5
Product page · Siemens S5 · SIMATIC S5 processors · Used Siemens equipment
Siemens and external references
+ Siemens 6ES5 948-3UA23 data sheet — manufacturer document hosted by All4SPS: S5-155U CPU 948, 1664 KB RAM.
+ Siemens S5-135U/155U System Manual — 6ES5 998-0SH21, Edition 07: Section 5.1 covers this hardware version; distinguish it from the older CPU 948 section.
+ Siemens CPU 948 Programming Guide — 6ES5 998-3PR21, Release 04: operating states, memory, diagnostics and execution times.
+ Siemens CPU 928B/CPU 948 Communication Manual: interface hardware, protocols and parameter assignment.