6ES5 434-4UA11

Siemens 6ES5 434-4UA11 — 32-Channel TTL, CMOS and NAMUR Digital Input Module

The Siemens 6ES5 434-4UA11 is a 32-channel, 5–15 V DC digital input module for the SIMATIC S5 U range. Its digital inputs evaluate TTL, CMOS and suitable NAMUR sensor signals. It is used with S5-135U, S5-150U and S5-155U systems and their U-range expansion units.

When connecting a TTL output, CMOS signal or NAMUR sensor, distinguish the supply voltage from the signal level. A 24 V L+/L− supply does not permit 24 V at a TTL input. Check the output type and wiring diagram when selecting two-wire/NAMUR sensors.

TTL, CMOS and NAMUR thresholds

TTL: 0–0.8 V for “0”, 2.4–5 V for “1”. CMOS: 0–0.3 × LH+ for “0”, 0.7 × LH+–LH+ for “1”. NAMUR: ≤1.2 mA for “0”, ≥2.1 mA for “1”. NAMUR evaluation is based on current; a voltage reading on a multimeter alone is insufficient.

Response time and isolation

Maximum input frequency is 100 Hz. Typical input delay is 3 ms, with a specified range of 1.4–5 ms. Consider these times alongside input/output processing and the PLC program. All 32 inputs form one galvanically isolated group; the channels are not individually isolated.

Supply and front connector

For sensor wiring, LH+ is 5 V for TTL or 5–15 V for CMOS. The manufacturer's NAMUR wiring table specifies a separate supply and bridging arrangement. NAMUR support does not make this module an intrinsically safe Ex i interface.

The module uses a 42-pin front connection. The manual lists the 20 mm crimp 6ES5 497-4UA12 for a fan-cooled arrangement and the 40 mm screw-terminal 6ES5 497-4UB12. Check the front plug and wiring against the rack arrangement. Maximum unshielded cable length is 200 m for TTL/CMOS or 600 m for NAMUR; assess grounding and interference conditions too.

Addressing and revision differences

The module's switch sets its starting address; 32 inputs occupy four consecutive bytes. For example, a start of 80 (0x50) allocates IB 80–83, leaving 84 as the next free start. Check switch weights and orientation against the module label.

During fault finding, check field wiring, the F+/F− enable circuit and addressing together. Although 434-4UA12 shares the technical table, the drawing's X20 enable-mode jumper applies only to UA12. Other 434 codes, such as 434-7LA11, must not be treated as interchangeable from the family number alone.

Editor's note

Start by confirming the sensor's output type. A 24 V cabinet supply is no reason to apply that voltage to a TTL terminal; keep the nameplate and wiring diagram side by side.

If a TTL or CMOS input LED stays on after disconnection, give the board a fair check before condemning it. The manual states that an open input can read “1”; test both states with a suitable signal.

If sixteen channels become troublesome together, inspect their supply and return connections before replacing individual sensors. Include common points alongside channel-by-channel measurements.

Before fitting a spare, photograph the complete order code, address switches and front connector. Do not look for a UA12 jumper on a UA11 board and improvise a change.

For a used board, test all 32 channels in both signal states and keep the results with the S5 maintenance record. A few illuminated LEDs are only the start of a useful check.

OtomasyonAVM resources and PDFs

+ Siemens S5 main page · 6ES5 434-4UA11 model page · OtomasyonAVM S5 PDF archive.

+ Model data appears in Siemens U Periphery, 6ES5 998-0PC22, pages 41–43 / PDF pages 244–246. See the manufacturer document below for sensor wiring and revision details.

Related topics

+ 434-4UA12 · 434-7LA11 · 434-7LA12 · 497-4UA12 · 497-4UB12 · NAMUR sensors. Similar codes do not establish replacement compatibility.

Browse SIMATIC S5

+ S5 digital input modules · SIMATIC S5 central controllers · Siemens S5 · Used Siemens equipment.

Siemens and external references

+ Siemens U Periphery — English manufacturer manual, external archive copy: §5.5, pages 41–43; UA11/UA12 data, sensor wiring and the UA12-only X20 note. Addressing: pages 25–27; connectors: page 28.

+ Siemens U Periphery — official Russian manual: §5.5, pages 4-42–4-44; exact 434-4UA11 coverage.

+ Siemens 6ES5434-4UA11 product record.