6ES5 530-3LA11

Siemens SIMATIC S5 CP 530 — 6ES5 530-3LA11

The Siemens 6ES5 530-3LA11 is the compact CP 530 SINEC L1 communications processor for S5-135U and S5-150U central racks. This S5 communications module exchanges data as a master or slave at 9,600 bit/s. Its 20.3 mm front panel has two 15-pin sockets, one for a programming device and one for the BT 777 bus terminal.

A SIMATIC S5 CPU can use the link to read a machine-ready signal from another station and send back a cycle enable. As the master, the CP 530 polls each station in sequence. A SINEC L1 network has one master and up to 30 slaves.

PG, TTY and RS-485 connections

Use the appropriate S5 programming cable to connect a PG 615 or PG 675 to socket X4. Socket X5 connects to the BT 777. The card side uses a 20 mA TTY current loop, and the BT 777 converts it to RS-485 on the bus side.

Siemens lists the 6ES5 777-0BB00 BT 777 with a 1 m connecting lead and the 6ES5 777-0BC00 with a 2 m lead. The 6ES5 777-1BC00 is the optically isolated 2 m version. Stations are linked by four-core shielded cable. Follow the installation manual for cable routing and bonding the cable shield to protective earth.

Rack, supply and CP 530 variants

The compact 3LA11 has two 48-pin ES 902 backplane connectors. Siemens shows the card held by a locking bar in the S5-135U central rack and in the S5-150U central rack. Check the +5 V (±5%) and +24 V (+25%/−15%) rails on the rack backplane. Siemens lists 0.35 A on the +24 V rail.

In an S5-115U, this compact version requires an adapter housing and a suitable S5 rack power supply. The Siemens table excludes the 6ES5 951-7LB12 for the compact card. The 6ES5 530-7LA11 and 6ES5 530-7LA12 are block-type versions. The 6ES5 530-3LA12 is another compact CP 530 order number. The CP 535 uses a different network, SINEC H1.

COM 530 addressing and configuration backup

Set the logical address from 1 to 254 that the CPU uses to reach the CP in the COM 530 SYSID area. A CP acting as a slave needs a SINEC L1 station number from 1 to 30. The master requires a polling list. A slave uses its station number in SYSID without a polling list. Check the CP address in the PLC program against the COM 530 configuration.

Parameters can be stored on a plug-in S5 memory submodule or in the CP’s RAM. The manual lists the 6ES5 375-0LC41 EEPROM and 6ES5 375-0LD11 RAM as options. Removing the CP from the rack clears the RAM contents.

Front-panel LEDs and diagnostics

When troubleshooting, read RN as run, ST as stop, MF as module fault and BF as bus fault. If BF is on, check the polling list and the station that failed to respond in COM 530. For monitoring traffic on the TTY side, Siemens shows a PG 675 running FOX-PG with the 6ES5 321-0AA11 diagnostic adapter. This is one of the S5 interface accessories used for diagnostics.

Editor’s note

Identify the card. Check the 3LA11 suffix, front-panel width and number of backplane connectors before ordering a spare.

Record the rack. Photograph the rack label, the card slot and any adapter housing before removal. For an S5-115U, record the power supply order number as well.

Back up the configuration. Save SYSID, the master polling list and any interrupt list from COM 530. Record the memory submodule order number.

Label the sockets. Mark the PG lead X4 and the BT 777 lead X5. Record the incoming and outgoing pairs at the bus terminal before disconnecting them.

If BF is lit. Start with the COM 530 error buffer. Check the power, address and BT 777 connections of the station that failed to respond.

OtomasyonAVM resources and PDFs

SIMATIC S5 communications modules · S5-135U 6ES5 135-3UA11 central rack and manual · S5-150U 6ES5 150-3SB61 central rack and manual

OtomasyonAVM Siemens S5 PDF archive

Related topics

CP 530 6ES5 530-3LA12 · CP 530 6ES5 530-7LA11 · BT 777 6ES5 777-1BC00 · 6ES5 321-0AA11 diagnostic adapter

Back to the S5 range

S5 communications modules · SIMATIC S5 modules · Siemens SIMATIC S5

If you have a CP 530 to sell, send a label photo, quantity and operating condition to otomasyonavm@gmail.com.

Siemens and external references

Siemens SINEC L1 / CP 530 manual — §1.5, 6ES5 530-3LA11 specifications

Siemens CP 530 — §3.2, SYSID and COM 530 configuration · Siemens CP 530 — §4.1, interfaces and pin assignments