Siemens 6ES5 951-7LB12 — S5-115U/H PS 951 Power Supply
The Siemens 6ES5 951-7LB12 is a SIMATIC S5 PS 951 rack power supply listed for the S5-115U/H. It takes a 115/230 V AC mains input and supplies 5 V DC at 3 A to the backplane. The order number is listed without a backup battery.
The unit powers the CPU and modules in the S5 rack. In an S5-115U rack such as the CR 700-1, check the rack label and the 5 V load when assessing a configuration with a CPU 942 or CPU 944. On an S5-115H installation, verify the power supply order number on each rack.
Mains input and 3 A output limit
Before energising the unit, check its input label and voltage setting against the cabinet supply. Add up the internal 5 V current draw of the CPU and the digital input, digital output and analog modules. The 7LB12’s main output is rated at 3 A. Use the cabinet drawings to trace the separate field supplies for sensors and actuators.
Where interface modules connect expansion units, use the drawings to identify which rack supplies each section. During fault finding, trace the power wiring separately from the S5 signal and interconnect cables so you measure the intended circuit.
CP 530 and similar PS 951 models
The Siemens SINEC L1 power supply table shows the pairing of the 7LB12 with the CP 530 compact, 6ES5 530-3LA11 as unsupported. Check the CP label in the cabinet. The 6ES5 530-7LA11 is the block version and has its own mounting and supply information.
The 6ES5 951-7LB13 and 6ES5 951-7LB14 have similar order numbers. The 6ES5 951-7LB21 is rated for 120/230 V AC input and 5 V DC at 3 A output. When comparing units with the same output rating, check the full order number, rack and battery arrangement.
The 6ES5 951-7NB12 and 6ES5 951-7NB13 are 24 V DC input, 3 A models. The 6ES5 951-7LD11 belongs to the 7/15 A class. When selecting a spare, compare the input supply and load conditions along with the 5 V output.
Editor’s note
Start with the nameplate. Record the full order number and mains voltage setting. Have qualified maintenance personnel inspect the input circuit against the cabinet drawings after isolating the supply.
Check the 5 V rail under load. Record the reading with the CPU and modules in service and note which modules are fitted. Assess the input and output measurements together.
Check the manual for any special-function modules. For the IP 244 6ES5 244-3AA13, Siemens lists the 7LB14 from hardware revision 6 onwards in an S5-115U and requires a battery-backed slot. Match the power supply to the list for the module installed.
Record the battery status and program backup separately. Before removing the unit, check any battery circuit fitted and verify the program copy on the S5 memory card or programming device.
Ask about the load test when buying used. For used PLC power supplies, request a readable label photo, the input voltage setting and the load at which the 5 V reading was taken.
OtomasyonAVM resources and PDFs
Siemens S5 PLC overview · CR 700-1 central controller rack · CP 530 compact module
SIMATIC S5-115H system manual (English PDF) · SIMATIC S5 PDF archive
Related topics
7LB21 — 120/230 V AC input, 5 V at 3 A output · 7NB12 — 24 V DC input, 5 V at 3 A output
Browse SIMATIC S5
SIMATIC S5 range · S5 CPU and rack models
External references
6ES5 951-7LB12 product listing — input, output and battery · Siemens SINEC L1 / CP 530 manual — power supply table, p. 1-9 · Siemens IP 244 manual — power supply revision and slot requirements, p. 2-14