6ES5 951-7NB12
Siemens 6ES5 951-7NB12 SIMATIC S5-115U PS 951 Power Supply
The Siemens 6ES5 951-7NB12 is a PS 951 power supply for the SIMATIC S5-115U central rack. It takes a 24 V DC input and provides 5 V DC at 3 A for the rack electronics. This order number was supplied without a backup battery.
In a SIMATIC S5 cabinet, this unit powers the CPU and the control circuits on the I/O modules. The 3 A rating applies to the 5 V rack output. Trace the field supplies for devices connected to S5 digital inputs and loads driven by digital outputs separately on the cabinet drawing.
Which S5-115U racks are documented?
The 1987 S5-115U approval lists the 7NB12 for configurations with the CPU 941 (6ES5 941-7UA12) and CPU 942 (6ES5 942-7UA11). The same component table lists the CR 700-0 (700-0LA11), CR 700-1 (700-1LA11) and CR 700-2 (700-2LA11) central racks.
When sourcing a spare, read the full order numbers on the S5 rack and CPU. The approval cited here covers S5-115U configurations. For an S5-115H installation, use the documentation for its specific rack and configuration.
How does it compare with nearby PS 951 variants?
The 7NB13 and 7NB21 are separate 24 V DC input models in the 5 V, 3 A class. The 7LB13 and 7LB21 take AC power. The 7ND12 takes 24 V DC and belongs to the higher-current 7/15 A class. Match the input type, current rating and full order number when selecting a spare.
Programming EPROMs with the PG 615
Siemens’ PG 615 manual states that EPROM programming is not assured when the programmer is connected to an S5-115U fitted with the 7NB12. The note concerns the voltage required to write the EPROM. Before starting, check the S5 memory module type and compare the PG 615 cable and adapter with the arrangement in the manual.
Editor’s note
Record all three nameplates. Photograph the rack, CPU and power supply labels for the same service record. Check the 7NB12 suffix on the supply label before ordering.
Trace the supply if the rack drops out at start-up. Have qualified maintenance staff check the 24 V feed under load during start-up. If the Siemens S5 PLC drops out, record the CPU indicators and any alarms on the S5 interface modules.
Calculate the rack load module by module. Add the 5 V current requirements for the installed CPU and I/O cards using their technical data. Compare the total with the 7NB12’s 3 A rating.
Verify the program backup before shutdown. Record the installed memory type and the existing battery arrangement. If the work includes an EPROM operation with a PG 615, check its connection arrangement before service begins.
Ask for a start-up test under load when buying used. Request the rack and CPU order numbers, the 24 V input conditions and the measured 5 V output under load. Use the S5 maintenance guide alongside the manuals for the actual rack and CPU.
OtomasyonAVM resources and PDFs
S5-115U CR 700-1 central rack · S5-115U CPU 942 hardware page · SIMATIC S5 hardware overview and manuals
OtomasyonAVM S5 PDF archive. The external references below include the component record for the exact 7NB12 order number and the PG 615 manual.
Related topics
PS 951 7NB13, 24 V DC input and 3 A output · PS 951 7NB21 power supply · PS 951 7LB21 AC-input model
S5 navigation
Siemens S5 PLC · SIMATIC S5 · S5 power supplies · S5 racks
External references
S5-115U CPU 941 and CPU 942 approval, component table by order number (Spanish PDF). Printed page 22643.
Siemens PG 615 manual, EPROM programming note for the 7NB12 (German PDF). Section 2.3.1, printed page 2-27.
Niemann SIMATIC S5 parts list, input and output ratings for the 6ES5 951-7NB12 (PDF).