Siemens 6ES5 948-3UA21 – CPU 948-2, 1664 KB RAM
Siemens 6ES5 948-3UA21 is a CPU 948-2 central processing module for SIMATIC S5-155U systems. It provides 1664 KB of internal user RAM and executes STEP 5 programs. This S5 CPU version serves machine and process applications requiring substantial program and data memory. It supports single-processor operation and appropriately configured multiprocessor systems.
Memory capacity and related CPU numbers
The 6ES5 948-3UA11 version has 640 KB of user RAM, whereas 948-3UA21 has 1664 KB. When considering 6ES5 948-3UA22 or 6ES5 948-3UA23, compare the order suffix, revision and mechanical construction separately. In particular, the single-slot CPU 948B identified as 3UA23 must be distinguished from the double-slot 3UA21 described here.
A Flash EPROM card from the S5 memory card range stores the program in nonvolatile memory; it does not increase internal working RAM. Siemens catalog options include 6ES5 374-2KH21 – 256 KB, 6ES5 374-2KK21 – 1 MB and 6ES5 374-2KL21 – 2 MB. Select capacity for the program and data to be stored. An overall reset erases existing RAM contents and copies the inserted card contents into RAM.
Execution speed and program resources
The Siemens ST 50 catalog specifies 0.18 µs for bit operations and 0.5 µs for word operations on CPU 948. These are individual operation times, not the complete machine scan time. The CPU provides 256 timers and 256 counters as program resources. Physical input, output and high-speed counting capabilities depend on the installed peripheral modules and system arrangement.
PG connection and second interface
The integrated SI1 is a 15-pin TTY PG interface; the manual specifies 9600 bit/s for the serial PG connection. Select the S5 connecting cable and converter accordingly. SI2 accommodates an optional interface submodule; the 6ES5 752-0AA53 PG module is one part used for this purpose. Check separately whether an SI2 submodule is fitted and included in the offer.
Supply and rack installation
The classic CPU 948 construction of 3UA21 occupies two slots in the S5 rack. The manual specifies a 5 V DC ±5% supply and 3.6 A typical CPU current. Include the memory card and fitted interface load when assessing the S5 power supply. Keep the two interconnected CPU boards together and disconnect power before removal or insertion.
For multiprocessor installations, compare CPU placement and the 6ES5 923-3UC11 COR 923C coordinator arrangement with the existing chassis documentation. Physical fit alone does not establish the correct CPU position. Photograph processor placement, jumper settings and connections before replacement.
Program transfer and diagnostics
Prepare the STEP 5 software and project backup before PLC programming. When transferring from another CPU family, review DX 0 configuration and standard function blocks separately; Siemens requires adaptation in these areas when moving from CPU 928B to CPU 948. During PLC debugging, record RUN, STOP, SYS FAULT and indicators such as QVZ, ADF and ZYK together. For Siemens S5 PLC maintenance, reaching RUN alone does not establish correct operation of the complete application.
Editor’s Note
When buying used Siemens equipment, verify 948-3UA21 on the label and 1664 KB memory through the PG. A similar exterior does not make the 640 KB version the same item. Keep photographs of the label and revision with the service record.
Back up the program and required data blocks before removing a working CPU. An installed Flash card does not establish that its program is current. Compare the last working project with the card contents before initiating an overall reset.
Do not condemn a CPU merely because it is in STOP. Read the indicators and PG diagnostics first. Missing peripherals, incorrect configuration or addressing errors can also stop the system. Clearing memory before recording the cause can remove useful evidence.
Test the SI1 connection and, if supplied, test the SI2 submodule using a suitable arrangement. Confirm in writing whether the memory card and interface submodule are included. Their presence in a photograph does not guarantee delivery.
Do not finish testing with an empty program alone. In a suitable setup, check memory access, power cycling and application communication. Inspect the board interconnection and backplane connectors, and preserve known working jumper settings.
OtomasyonAVM resources and PDFs
+ Shared SIMATIC S5 PDF archive – S5-115 PDF files. Use the system manual and CPU 948 programming guide below together.
Related topics
+ 6ES5 948-3UA11 · 6ES5 948-3UA22 · 6ES5 948-3UA23 · 6ES5 752-0AA53 · 6ES5 374-2KL21
Browse SIMATIC S5
+ S5 CPU models · S5 memory cards · S5 interface modules · S5 racks and chassis · Siemens SIMATIC S5
Siemens and external references
+ Siemens S5-135U/155U System Manual – C79000-G8576-C199-07. Section 5.2: classic CPU 948; Section 5.1: single-slot CPU 948B.
+ Siemens CPU 948 Programming Guide – 6ES5 998-3PR21, Release 04. Memory, DX 0, program transfer and diagnostics.
+ Siemens ST 50 catalog – CPU 948. Printed pages 4/27–4/29: specifications and the 948-3UA21 order entry; Siemens document hosted by EandM.