GD35 / Goodrive35
INVT GD35 / Goodrive35 closed-loop vector drive
The INVT Goodrive35 (GD35) is an AC variable frequency drive for machines that need steady motor speed as load changes or controlled motor torque. With a compatible encoder and PG card, the drive reads actual motor speed. In closed-loop control, it corrects the difference between actual and commanded speed. INVT documents GD35 installations coordinating multiple motors in a paper mill and controlling spindle speed on a milling machine.
Control modes and model selection
The range offers three control approaches. SVPWM controls motor voltage and frequency. Sensorless vector control (SVC) estimates motor behaviour from electrical measurements. Feedback vector control (FVC) uses measurements from the motor shaft. INVT lists induction and permanent-magnet synchronous motors. Confirm which mode applies to your motor. The guides to V/f control, FOC and speed control versus torque control explain where each approach fits.
In GD35-5R5G-4-H1, 5R5 denotes 5.5 kW, G a constant-torque load, 4 the three-phase 380 V nominal class, and H1 the feedback option. The V4.3 manual lists -4 models from 1.5 to 315 kW and three-phase 660 V nominal -6 models from 22 to 630 kW. When selecting a drive, check motor rated current, rated frequency and the load duty cycle together.
Matching the encoder and PG card
C1 supports 24 V incremental encoders, H1 supports 5 V or 12 V incremental encoders, and D1 is for a resolver. H2 is for high-speed differential 5 V incremental encoders, while S1 is the 1 Vpp sin/cos option. Option availability depends on the drive rating. Match the full model code against sections 3.5 and 3.6 of the manual. Check the encoder output type, TTL/HTL signal levels and differential signalling separately.
P20.00 sets encoder type, P20.01 sets pulses per revolution and P20.02 sets direction. During commissioning, P00.01 sets the run-command source and P00.06 sets the main frequency reference source. If the keypad shows a reference but the motor stays still, check those two sources first.
Software, manual and fault finding
INVT lists the GD35 for INVT Studio, which can read, save and monitor parameters. The GD35 manual covers Modbus RTU over RS-485. For Ethernet, check the fitted communications card. Before installing the software, check operating-system support. See INVT VFD Software and INVT VFD Documents for the corresponding resources.
The INVT fault-code index covers multiple drive families. For the GD35 codes, see section 8.5 of the V4.3 manual. ENC1o indicates loss of encoder feedback, ENC1d an encoder direction fault, OC1 overcurrent during acceleration and OV2 overvoltage during deceleration. When investigating OC1 or OV2, check the acceleration and deceleration ramps, load and DC bus behaviour together. If the load drives the motor, check the model’s dynamic braking arrangement and braking resistor limits in section D.8 for handling the regenerated energy.
Editor’s Note
Buying a used GD35? Ask for two clear photos, one of the drive nameplate and one of the PG card label. Two drives with the same kW rating can have different feedback inputs.
If the old drive is available, back up its parameters. Write down the motor nameplate data, encoder pulses per revolution and where the speed command comes from.
If the shaft hunts at low speed, check for play in the encoder coupling, verify feedback direction and inspect cable shielding before touching the gains.
Use the machine’s safe test procedure for initial motor autotuning and direction checks. The manual requires the motor to be uncoupled from the load for rotating autotuning.
Before resetting a fault, record its code and whether it happened during acceleration or deceleration. When replacing a drive, make sure you can open the parameter backup before performing a factory reset.
Related topics
For winding and unwinding, see the tension-control GD35-07 page. For other drive families, see Goodrive350 and GD350A. For line automation, see INVT PLC and INVT HMI.
INVT category path INVT brand home › INVT user manuals › INVT VFD drives
Manufacturer references
Goodrive35 operation manual V4.3, English PDF · Fault history and code table · INVT Studio technical page · GD35 milling machine application · Paper mill application