what is acc dec time?

VFD Acceleration/Deceleration (Ramp) Time - Time/Frequency Graph Animation
Time (s) Output Frequency (Hz) 0 50
What is acceleration time? (for vfd)

Acceleration time, also known as ramp time or start time, is a parameter that is used to control the speed at which an electric motor accelerates to its full speed when it is started. It is a common feature of variable frequency drives (VFDs), which are used to control the speed and torque of electric motors. Generally, it is measured in seconds and this time interval is crucial for the proper functioning of the engine

The acceleration time of a motor is the amount of time it takes for the motor to reach its full speed after it is started. It is typically measured in seconds, and can be set to a specific value depending on the application. For example, in a conveyor system, the acceleration time may be set to a relatively short value in order to quickly bring the conveyor up to full speed, while in a pump system, the acceleration time may be set to a longer value in order to reduce the strain on the pump and prolong its lifespan.


The acceleration time of a motor can be adjusted in the VFD's control settings, and it can be set to a fixed value or it can be programmed to vary based on the load on the motor. In some systems, the acceleration time may be set to a fixed value that is optimal for the specific application, while in others, the acceleration time may be adjusted dynamically based on the load on the motor in order to optimize performance and efficiency.

Acceleration time is an important parameter to consider when designing and setting up a motor control system, as it can have a significant impact on the performance and efficiency of the system. Generally, it is measured in seconds and this time interval is crucial for the proper functioning of the engine


what is deceleration? (for vfd)

In the context of a variable frequency drive (VFD), deceleration refers to the process of decreasing the speed of an electric motor. It is the opposite of acceleration, which is the process of increasing the speed of an electric motor. Deceleration can be controlled and regulated by the VFD, which is used to adjust the frequency and voltage of the power supplied to the motor.

The deceleration of an electric motor is typically measured in terms of acceleration, with a negative acceleration indicating deceleration. The rate at which the motor decelerates can be controlled by adjusting the frequency and voltage of the power supplied to the motor. In a VFD, the deceleration rate can be set to a specific value, or it can be programmed to vary based on the load on the motor.


Deceleration is an important feature of a VFD, as it can be used to control the speed and torque of the motor in real-time. It is commonly used in applications where precise and efficient control of the motor is required, such as in conveyor systems, pumps, and other types of machinery. Deceleration can help to improve the performance and energy efficiency of an electric motor system, and it is an important parameter to consider when designing and setting up a motor control system.


ACC (Acceleration) time is a term used in the design and operation of elevator systems to refer to the time it takes for the elevator to accelerate from a stop to its rated speed. The ACC time is an important factor in determining the overall performance of an elevator system, as it affects the speed and smoothness of the elevator's movement.

The ACC time is typically specified in the design of the elevator system and is based on the characteristics of the elevator motor, the size and weight of the elevator car, and other factors. The ACC time is typically measured in seconds and can vary depending on the specific requirements of the elevator system.

In general, a shorter ACC time results in a faster and smoother acceleration of the elevator, while a longer ACC time may result in a slower and less smooth acceleration. The ACC time can be adjusted by changing the design of the elevator system or by using different types of control systems to optimize the acceleration of the elevator.


DEC (Deceleration) time is a term used in the design and operation of elevator systems to refer to the time it takes for the elevator to decelerate from its rated speed to a stop. The DEC time is an important factor in determining the overall performance of an elevator system, as it affects the speed and smoothness of the elevator's movement.

The DEC time is typically specified in the design of the elevator system and is based on the characteristics of the elevator motor, the size and weight of the elevator car, and other factors. The DEC time is typically measured in seconds and can vary depending on the specific requirements of the elevator system.

In general, a shorter DEC time results in a faster and smoother deceleration of the elevator, while a longer DEC time may result in a slower and less smooth deceleration. The DEC time can be adjusted by changing the design of the elevator system or by using different types of control systems to optimize the deceleration of the elevator.

+ What is Coast (free) stop?

+ What is Dc Brake?

+ What is speed search in VFD?

+ What is flying start in vfd?

+ What is STO (safe torque off)

+ What is Automatic ramping in VFD?