Delta DVP60EH00T2
Delta DVP60EH00T2 – DVP-EH2 PLC with High-Speed Transistor Outputs
The Delta DVP60EH00T2 is a PLC main unit from the DVP-EH2 series. It operates from 100–240 V AC, 50/60 Hz. Its CPU runs the machine sequence and controls high-speed inputs and transistor outputs. Cut-to-length, labelling and part-feeding machine automation can combine encoder tracking, positioning and on/off control in one program. Delta’s installation drawing gives the 60EH00 T2 enclosure a width of 212 mm.
24 V DC inputs and high-speed counting
Use an inductive sensor to detect a metal target, a photoelectric sensor to detect a passing part or a limit switch to detect end of travel. Match the S/S common to the sensor’s NPN or PNP output using Delta’s sink/source wiring diagram.
The 2014 EH2 installation sheet lists X0, X1, X4, X5, X10, X11, X14 and X15 in the 200 kHz input group for the 60EH2. When connecting an encoder, check the signal level, high-speed counter assignment and limit for the selected counting mode. PLC inputs and outputs use octal addresses, so X10 follows X7. Compare the full X/Y mapping with the terminal markings and the existing program.
NPN outputs and Y0–Y3 pulse points
Delta shows an NPN type 2 open-collector output circuit for the 40/60EH2. Y0–Y3 are the 60EH2’s high-speed pulse output points rated up to 200 kHz. For pulse and direction assignments, check the motion instruction, the servo drive input circuit and both manufacturers’ wiring diagrams.
The sheet specifies 5–30 V DC for the transistor output circuit. Resistive load limits are 0.5 A per point and 4 A per common. For coils, check the inductive load rating and use suitable surge suppression. Check field supply fuse protection, cabinet grounding and pulse cable shielding against the wiring diagram. If encoder counts become erratic during acceleration, check cable routing and electrical noise.
Programming software and cable
Use Delta WPLSoft to read, monitor and back up the EH2 ladder program. If you use ISPSoft, check that your installed version offers the EH2 CPU type. Set up the serial connection in COMMGR.
Connect the PC through the 8-pin mini-DIN socket on COM1 RS-232. Delta PC-to-PLC serial cable options include DVPACAB215 (1.5 m) and DVPACAB230 (3 m). If the computer has no serial communication port, install the driver for a USB-to-RS-232 adapter and select the COM port Windows assigns.
COM2 RS-485 is available for field communication with an HMI or drive. On a Modbus/RS-485 network, check the station address, baud rate, parity and ASCII/RTU selection against the existing program. Back up the program and any retained data the machine needs before online troubleshooting.
Editor’s Note
For a used unit, ask for clear photos of the DVP60EH00T2 nameplate and both terminal rows. Use those photos to identify the connections on the actual unit.
Stop the machine and safely isolate the output loads before testing. Confirm that the PLC can be read through COM1 and save a backup before writing anything to the CPU.
Test the high-speed inputs with slow pulses first. Check the counting direction and number of pulses in the monitor. Then test at the speed the application requires.
When testing Y0–Y3, check how the drive accepts an NPN open-collector pulse. If pulses are present and the axis stays still, start with the drive input mode, common connection and fault status.
If a Y indicator lights and the load stays off, measure the load supply and the relevant output common first. On the bench, check that channel with a known-good DC test load.
Keep the PLC backup, terminal photos, serial settings and drive parameters together before replacement. Verify the reference sensor, travel limits and pulse/direction mapping when recommissioning.
Related Delta models
The DVP40EH00T2 is an EH2 model with 24 inputs and 16 transistor outputs. The DVP48EH00T2 provides 24 inputs and 24 outputs, while the DVP64EH00T2 provides 32 inputs and 32 outputs. For a differential pulse interface, see the DVP32EH00M2 wiring. The similarly named DVP60ES00T2 belongs to the DVP-ES family. Compare the program, terminal layout and expansion support for the exact models before replacing a CPU.
OtomasyonAVM PDF files and internal references
Delta DVP PLC PDF Files · Early DVP-EH2 installation sheet (2006, English PDF)
Delta DVP PLC series · Delta PLC overview · Used Delta equipment
External references
Delta DVP-EH2 installation sheet (2014) – 60EH00 T2 supply, input and output specifications · Delta DVP-PLC Application Manual – Programming (2014, English) · Delta – ISPSoft and COMMGR serial connection