Delta DVP32EH00MT
Delta DVP32EH00MT – DVP-EH3 PLC with Two Differential Pulse Axes
The Delta DVP32EH00MT is a compact PLC main unit in the DVP-EH3 series. It operates from 100–240 V AC and provides 16 digital inputs and 16 digital outputs. The built-in CPU runs the machine sequence and generates differential pulse commands up to 200 kHz on two axes. Typical PLC applications include labelling, cut-to-length and part-feeding machines that combine encoder tracking with positioning.
Differential encoder inputs
X0, X1, X4 and X5 are 200 kHz differential inputs, with separate +/− terminals for each signal. X0/X1 and X4/X5 can serve two A/B encoder groups. Before connecting a line-driver encoder, check the output standard, pair polarity and high-speed counter assignments. Turn the encoder by hand and check the counting direction and the change in counts over one revolution.
The remaining inputs belong to the 24 V DC input group. If an inductive sensor or limit switch provides the reference position, match the sensor’s NPN or PNP output and the S/S common to Delta’s sink/source diagram. Use the M3/MT input diagram for the differential X terminals.
Outputs and servo drive connection
Y0–Y3 are 5 V differential outputs rated up to 200 kHz. These four points serve two high-speed pulse axes. Y4–Y17 are the 12 general-purpose transistor outputs, numbered in octal. They can switch general machine loads within the electrical ratings.
For a servo system, start with the command input on the servo drive. Verify the differential pulse input, pulse/direction format and pulse scaling against the machine program. Delta’s EH3 installation sheet includes an M3/MT differential wiring example for the ASDA-A2. Follow the manufacturer’s diagram for signal cable routing, shields and grounding. Check for electrical noise if an axis loses position at higher speeds.
Programming software and cable
WPLSoft and ISPSoft are used with DVP-EH3 PLCs. Before reading an existing ladder program, check the software used for the original project and select the EH3 CPU type. In ISPSoft, configure the serial connection in COMMGR.
Connect the PC to COM1 RS-232 with the DVPACAB2A30 programming cable. It has a female DB9 at the PC and an 8-pin mini-DIN at the PLC. If the computer has no serial communication port, use a USB-to-RS-232 adapter with its driver installed and select the COM port assigned by Windows. For an HMI or drive on COM2 RS-485, match the Modbus/RS-485 station address, baud rate and frame settings. Back up the program before online troubleshooting.
Editor’s Note
For a used unit, ask for a clear photo of the DVP32EH00MT nameplate and its differential +/− terminals. The M3 and T3 models share a similar enclosure and have different output arrangements.
On the bench, test both encoder groups individually where possible. Check the A/B signals and confirm that forward machine travel counts in the direction expected by the program.
Test each axis’s pulse and direction signals separately. If a pulse command reaches the drive and the axis stays still, start with the input mode, +/− pairs and drive fault status.
If an axis behaves at low speed and loses position as it accelerates, check the encoder and pulse cable shields, routing and connections at both ends.
Check PLC inputs and outputs individually. If a general-purpose Y indicator turns on and the load stays off, measure the relevant common and DC load supply.
Keep the PLC backup, drive parameters and terminal photographs together before replacing the CPU. Make the first movement under safe test conditions at low speed and verify direction and limits.
Related Delta models
The DVP32EH00M3 shares the Y0–Y3 differential output arrangement. The remaining outputs are relays on the M3 and transistors on the MT. The DVP32EH00T3 is the standard transistor-output version, and the DVP32EH00R3 is the standard relay-output version. For additional inputs, the DVP40EH00T3 provides 24 inputs and 16 transistor outputs. Compare the differential terminals and field wiring by model before replacing a CPU.
OtomasyonAVM PDF files and internal references
Delta DVP PLC PDF Files · Delta DVP PLC series · Delta PLC overview · Used Delta equipment
External references
Delta DVP-EH3 installation sheet – M3/MT input and output diagrams · Delta DVP catalogue – DVP32EH00MT model table · Delta PLC Link application note – WPLSoft and ISPSoft