Delta DVP Slim specialty modules
Delta DVP Slim specialty modules
Delta DVP Slim specialty modules add analog measurement, analog control or direct temperature measurement to a Delta DVP PLC. The four modules cover distinct jobs. The DVP06XA-SH combines analog inputs and outputs, the DVP06AD-SH adds six analog inputs, the DVP04PT-SH reads platinum RTDs, and the DVP08RT-S reads NTC thermistors. Start with the signal at the machine, then check the channel count and the exact PLC CPU model.
Choose between the four modules
| Model | Channels and signal type | Typical application |
|---|---|---|
| DVP06XA-SH | 4 analog inputs + 2 analog outputs | Read sensors and send a reference to a drive or proportional valve. |
| DVP06AD-SH | 6 analog inputs | Monitor several pressure, flow or level transmitters in the PLC. |
| DVP04PT-SH | 4 platinum RTD temperature inputs | Read Pt100 probes on tanks, molds or heating zones. |
| DVP08RT-S | 8 NTC thermistor inputs | Monitor multiple cooling or temperature zones with compatible NTC probes. |
Analog inputs and outputs in a control loop
The DVP06AD-SH brings six measurement points into one module. The DVP06XA-SH combines four measurement channels with two control outputs. In a pump application, a pressure transmitter feeds an analog input, and the analog output sends a speed reference to a variable-frequency drive. If you use a PID loop to hold pump pressure, configure the measurement scale and speed reference limits separately. Check the selected range, common terminals and the signal accepted by the connected device.
Scaling example. A linear 4–20 mA / 0–10 bar transmitter should represent 5 bar at 12 mA. If your PLC reads raw counts, map the endpoints using the raw data range for the selected input mode. With a two-wire sensor, account for loop power too. Check the pressure sensor range, the module’s electrical input range and the units shown on the HMI separately.
Analog and digital inputs carry different information. Use the DVP Slim digital modules section for an on/off pressure switch and the DVP Slim analog modules section for a varying pressure reading.
Pt100, NTC and thermocouple inputs
For the DVP04PT-SH, compare the Pt100 probe wiring arrangement with the module’s terminal diagram. For the DVP08RT-S, check the NTC probe’s nominal resistance at 25 °C and its resistance–temperature curve. The earlier DVP technical guide lists 3977 K (B25/86) and 3630 K (B25/85) curves for 10 kΩ NTC probes at 25 °C. Two probes with the same nominal resistance can have different curves. Check a plausible display reading against a known temperature during commissioning.
For a type J or K thermocouple, see the DVP04TC-S and the DVP Slim temperature modules. If the probe label is missing, see the Pt100 and thermocouple comparison. For PLC-based temperature regulation, plan the measurement, PLC-based PID loop, output device and heater control together. If the loop needs to run independently, consider a standalone temperature controller.
CPU compatibility, software and cable
Find your main unit under DVP-SS2, DVP-SA2, DVP-SX2, DVP-SV2 or DVP-SE. Check the complete CPU order code, expansion side, supported module count and power budget. If the expansion chain in a used machine has changed, match the module numbers in the project to the physical order.
Use WPLSoft or ISPSoft for PLC programming, depending on the CPU and the existing project. For an ISPSoft connection, select the communication driver in COMMGR. Choose the Delta DVP programming cable for the actual CPU port. For example, Delta’s DVP-SA2 cable diagram shows UC-PRG020-12A and UC-MS020-01A for the COM1 RS-232 connection. Check which interface your chosen cable needs at the PC end. A CPU that supports programming over Ethernet can connect that way.
Where the module is accessed through CR control registers, follow FROM reads and TO writes in the ladder program. Cross-check the module number, CR address and data length against the CPU instructions and the module’s own register table. See how PLC input and output modules handle data before testing a spare.
Replacement models for maintenance
Delta’s China product lifecycle notice gives March 31, 2025 as the discontinuation date for the three -SH models. It gives DVP06XA-S2 for DVP06XA-SH, DVP06AD-S for DVP06AD-SH, and DVP04PT-S for DVP04PT-SH. Before a conversion, compare terminal order, channel modes, raw scaling, CR tables and CPU compatibility. When servicing a machine with a DVP08RT-S, include the existing NTC probe curve in the replacement check.
Editor’s Note
When buying a used module, ask for photographs of the front label, side label and terminals. A suffix can change the wiring and the program settings you need.
Back up the existing PLC project first. Record the analog ranges, CR addresses and expansion order with photos or a simple table.
On the bench, feed a known signal into the inputs you plan to use. On the XA module, measure both analog outputs with a suitable test load.
Test a temperature module with the same probe type used in the machine. Compare readings at room temperature and at a second known point.
If the reading jumps when a drive runs, check for electromagnetic interference. Review cable routing, shield termination and grounding against the wiring instructions.
After fitting a compatible spare, watch the actual readings first. Bring the drive or valve reference into service in a controlled test.
Related topics and PDF files
Delta DVP PLC PDF files · Delta DVP-SA installation and expansion guide (Turkish PDF) · Delta PLC and HMI manuals
Delta DVP expansion modules · Slim load cell modules · Slim positioning modules · Slim communication modules
Delta DVP PLC series · Delta PLC · Used Delta products
External references
Delta DVP discontinuation and replacement table (PDF) · Delta DVP module manual (PDF) · Delta DVP programming manual (PDF) · Delta PLC/HMI cable selection guide (PDF) · DVP08RT-S NTC input specifications, earlier DVP manual (PDF)