Delta DVP32EH00M2
Delta DVP32EH00M2 · DVP-EH2 PLC with Two Differential Pulse Axes
The Delta DVP32EH00M2 is a PLC main unit in the DVP-EH2 family. It has a 100–240 V AC supply, 16 digital inputs and 16 digital outputs. Typical uses include counting encoder pulses, running machine sequences and issuing positioning commands on cut-to-length and labelling equipment.
Differential encoder inputs
X0/X1 and X4/X5 form two differential input groups. Each signal has its own + and − terminals. Delta specifies a 200 kHz input bandwidth for these points. When selecting an encoder, check its line-driver output, A/B phases and the frequency limit for the selected counting mode.
The other digital inputs use 24 V DC field signals. When connecting an inductive sensor, photoelectric sensor or limit switch, match the PNP or NPN signal type and S/S input common to the panel schematic. Addressing is octal, so X10 follows X7.
Two pulse axes and field outputs
Y0/Y1 carry signals for the first differential axis and Y2/Y3 carry signals for the second. Delta specifies up to 200 kHz per axis for high-speed pulse output. The electrical table lists a 5 V DC differential signal level. When connecting a servo drive, check the pulse format, input level and PLS/SIGN terminals for the exact drive model. Figure 21 in Delta’s wiring sheet gives an ASDA-A2 example.
The terminal diagram groups field outputs Y4–Y7 and Y10–Y17 under C0, C1 and C2. Before connecting a contactor or another load, check the output circuit and electrical limits against the machine schematic.
Differences between the R2, T2 and M3 models
The DVP32EH00R2 is the standard EH2 model with relay outputs. The DVP32EH00T2 uses transistor outputs. The M2 adds differential connections for encoders and drives. The DVP32EH00M3 belongs to the EH3 generation. When replacing a CPU, check the project target, counter settings and motion instructions together.
Programming software and cable
Use WPLSoft or ISPSoft for PLC programming and ladder editing. Select the EH2 CPU target. For ISPSoft, configure and start the serial channel in COMMGR.
Connect the computer to COM1, the 8-pin mini-DIN RS-232 port. The DVPACAB230 serial cable can be used. If the PC has no serial port, install the USB-to-RS-232 adapter driver and select the COM number assigned by Windows.
The RS-485 interface on COM2 supports industrial communication with an HMI panel and other serial devices. For Modbus RTU, match device addresses, baud rate, parity and data format.
Editor’s Note
On a used M2, check the nameplate and differential terminals first. Photograph the +/− terminals, SG0 and output commons before disconnecting the CPU.
On the bench, read the program through COM1 first. Turn the encoder in a controlled test and verify that the count changes in the expected direction.
If the drive receives pulses and moves in the wrong direction, check the PLS/SIGN assignments, selected pulse format and drive direction parameter. Test each axis individually.
If the count becomes unstable when the motor runs, check the twisted-pair cable route, shield termination and panel grounding. Inspect the drive’s EMC filter connection if fitted.
If BAT.LOW is lit, back up the program, required retained data and drive settings before a planned shutdown. Keep the count scaling and direction settings in the machine folder.
Related topics and internal references
Delta DVP PLC PDF files · General DVP-EH2 installation sheet, 2006 (EN). See the 2014 sheet below for the M2 differential wiring diagrams.
Browse Delta · Used Delta equipment · Delta PLC · DVP PLC series
External references
Delta DVP-EH2 instruction sheet, 2014 · M2 Figures 8–10 and 21–23 · Delta DVP-PLC application and programming manual (EN) · Delta DVP catalogue and EH2 model table (EN)