Delta DVP20EH00R2
Delta DVP20EH00R2 | PLC with 12 inputs and 8 relay outputs
The Delta DVP20EH00R2 is a 100–240 V AC main unit in the DVP-EH2 series. It has 12 digital inputs rated at 24 V DC and 8 relay outputs. In packaging and conveyor machines, the PLC reads sensors. The CPU runs the sequence and switches field loads through its relay outputs.
Digital inputs and high-speed counting
The built-in PLC inputs and outputs use octal addresses X0–X13 and Y0–Y7. X10 follows X7. Before connecting an inductive sensor, identify its PNP or NPN output and check the S/S terminal in Delta’s sink/source wiring diagram.
For high-speed counting, Delta lists X0/X1 and X4/X5 input points in the 200 kHz class and X10/X11 in the 20 kHz class. When using an incremental encoder, check the count mode, signal level and frequency. For a differential line-driver encoder, select an electrical interface that matches the PLC input.
Relay outputs and load wiring
The relay contacts switch externally powered loads. Delta specifies 2 A per output and 5 A total per common for resistive loads. For coils, use suitable suppression and follow the load limits in the manual. If a servo drive requires a 200 kHz pulse command, consider the Y0 and Y2 transistor outputs of the DVP20EH00T2. The drive powers the servo motor.
Check the DIN rail layout, protective grounding and output common groups against the diagram. A compatible module such as the DVP04AD-H2 can add analog inputs.
Programming software and cables
Read and back up the existing ladder program with WPLSoft. ISPSoft also supports the EH2 target. Configure the ISPSoft connection through COMMGR. Confirm the CPU type and instruction support before writing the program to the PLC.
For COM1 (RS-232), use UC-PRG020-12A with a USB-equipped PC or UC-MS020-01A with a native RS-232 port. Install the USB cable driver and select the COM port assigned by Windows. For Modbus over COM2 (RS-485), match the station address, baud rate and serial frame settings. Delta PLC cable options
Related Delta models
The DVP20EH00T2 has the same I/O count with transistor outputs. The DVP16EH00R2 has 8 inputs and 8 relay outputs. The DVP32EH00R2 has 16 inputs and 16 relay outputs. The DVP20EH00R3 is a later EH3 model with 12 inputs and 8 relay outputs. When changing generations, check the terminal layout, serial communications, expansion modules and project compatibility.
Editor’s note
When buying used, zoom in on the nameplate. The R2, T2 and R3 suffixes affect field connections.
Before removal, back up the program, the retained data the machine uses and the communications settings.
Check the BAT.LOW indicator on the bench. Follow Delta’s procedure for battery service.
If a relay clicks but the load stays off, check the common supply and test the contact with a suitable load.
If the encoder count is erratic, check the X input pair, count mode and frequency before replacing the cable.
PDFs and internal references
Delta DVP PLC files · DVP-EH2 hardware and wiring sheet (PDF) · Delta DVP-EH2 · Delta DVP PLC series
External references
Delta DVP-EH2 instruction sheet, 2014 · Delta DVP ordering catalogue · Delta UC-PRG020-12A cable information · Delta WPLSoft and ISPSoft information