Delta DVP40EH00R

Delta DVP40EH00R – DVP-EH PLC with 24 Inputs and 16 Relay Outputs

The Delta DVP40EH00R is a PLC main unit from the first-generation DVP-EH series. It runs on 100–240 V AC, 50/60 Hz. The CPU has 24 digital inputs rated at 24 V DC and 16 relay outputs. Typical machine automation applications include conveyors, part feeders and packaging equipment. Delta’s dimension drawing lists an enclosure width of 158.8 mm.

Digital inputs and addressing

The built-in inputs are addressed X0–X27 and the outputs Y0–Y17. Addresses use octal numbering, so X10 follows X7. An inductive sensor can detect a metal part, a photoelectric sensor can detect a passing product and a limit switch can indicate the end of travel.

Check whether the field device has an NPN or PNP output and whether it is normally open or normally closed. Wire the S/S common according to Delta’s sink/source diagram. +24V and 24G are the auxiliary DC supply output terminals. When tracing PLC I/O, compare the terminal LED with the corresponding address in the software.

Relay outputs and load selection

Outputs Y0–Y17 switch through mechanical relay contacts. Delta’s output table lists 2 A per point, 5 A per common and voltage limits of 250 V AC / 30 V DC. For a contactor or solenoid coil, check the inductive load rating, inrush and total current through the shared C terminal. Follow the machine wiring diagram for output circuit fuse protection, coil suppression and cabinet grounding.

If the machine uses an encoder, check the signal level, X terminal and high-speed counter assignment against the first-generation EH documentation. If the drive needs a high-speed pulse command, select a transistor-output CPU or positioning module rated for that interface.

Programming software and cable

Use WPLSoft and select the first-generation EH CPU type to read, back up or monitor the ladder program. If you use ISPSoft, check that your version offers the original EH CPU target. Configure the serial connection in COMMGR.

Connect the PC to COM1 RS-232 with the DVPACAB2A30 programming cable. It has a 9-pin D-sub connector at the PC and an 8-pin mini-DIN connector at the PLC. If the computer has no serial communication port, install the driver for a USB-to-RS-232 adapter and select the COM port assigned by Windows.

COM2 RS-485 is available for Modbus/RS-485 communication with an HMI or other field device. When connecting to an existing network, check the station address, baud rate, parity and ASCII/RTU selection. Back up the program and the retained values the machine uses before online troubleshooting.

Editor’s Note

For a used unit, ask for a clear photo of the DVP40EH00R nameplate. Use the actual label to distinguish the R, R2 and R3 versions.

Check the POWER, RUN, ERROR and BAT.LOW indicators. If BAT.LOW is on, back up the machine program and retained data before battery maintenance.

If the Y LED comes on and the load stays off, check the supply at that output common first. Then isolate the channel from the machine and try a suitable bench test load.

If the load stays on after the Y command turns off, isolate the power safely. Disconnect the field wiring and check the relay contact for sticking.

If a relay fails again, check coil inrush and surge suppression before installing another CPU. Include the other loads on the shared common in the check.

Keep the terminal photos, program backup and serial settings before moving to EH2 or EH3. Compare the output commons, installed expansion modules and HMI addresses one by one.

Related Delta models

Within the first-generation EH range, the DVP40EH00T offers the same I/O count with transistor outputs. The DVP32EH00R has 16 inputs and 16 relay outputs. The DVP48EH00R has 24 inputs and 24 relay outputs.

The DVP40EH00R2 belongs to EH2, and the DVP40EH00R3 belongs to EH3. Both provide 24 inputs and 16 relay outputs. Check the CPU project type, terminal layout and installed modules before choosing a replacement.

OtomasyonAVM PDF files and internal references

Delta DVP PLC PDF Files · Delta DVP-PLC Application Manual – EH addressing (2017, English PDF)

Delta DVP PLC series · Delta PLC overview · Used Delta equipment

External references

Delta DVP-EH installation sheet – 40EH terminal layout and relay ratings (2006, English PDF) · Delta DVP-PLC Application Manual – Programming (2014) · Delta ISPSoft and COMMGR serial connection guide