Delta DVP32EH00T
Delta DVP32EH00T | 16 inputs, 16 transistor outputs and 200 kHz pulse output
The Delta DVP32EH00T is a 100–240 V AC main unit in the original DVP-EH series. It has 16 digital inputs rated at 24 V DC and 16 NPN open-collector transistor outputs. The PLC reads sensors. The CPU runs the machine sequence and sends positioning pulses to the drive.
Digital inputs and encoder counting
The built-in PLC inputs and outputs use octal addresses X0–X17 and Y0–Y17. X10 follows X7. When connecting an inductive sensor, identify its PNP or NPN type and check the S/S connection in the sink/source diagram.
For high-speed counting, use the EH counter table to check the incremental encoder signal level, single-phase or A/B counting mode and assigned X terminals. An encoder with differential line-driver outputs requires an electrical interface compatible with the 24 V input.
200 kHz pulse outputs and DC loads
Y0 and Y2 provide high-speed pulse output up to 200 kHz. Delta lists the remaining Y points as standard 10 kHz transistor outputs. Match the pulse and direction terminals to the program and the servo drive input mode. Delta’s ASDA-B manual includes a pulse wiring example for this CPU. The drive powers the servo motor.
When connecting a coil or interface relay, check output current, common groups and load suppression. Check the DIN rail layout and protective grounding during panel installation. An EH-compatible module such as the DVP04AD-H can add analog inputs.
Programming software and cables
Use WPLSoft to read and back up the existing ladder program. With an ISPSoft release that supports the EH CPU target, configure the connection through COMMGR. Check the original EH CPU type and instruction support before writing the program to the PLC.
Use DVPACAB2A30 for COM1 (RS-232, 8-pin Mini-DIN). The PC end is a 9-pin D-sub. On a USB-equipped PC, use a suitable USB-to-RS-232 adapter with its driver and select the COM port assigned by Windows. For Modbus over COM2 (RS-485), match the station address and serial settings. Delta PLC cable options
Related Delta models
The DVP32EH00R has the same I/O count with relay outputs. The DVP32EH00M combines differential pulse outputs and relay outputs. The DVP32EH00T2 belongs to EH2 and the DVP32EH00T3 belongs to EH3. For a replacement, compare the terminal layout, pulse channels, attached modules and program.
Editor’s note
When buying used, ask for a close-up of the nameplate. Check the T, T2 and T3 suffixes in the order code.
Before removal, save the PLC program, the retained data you need and the drive’s pulse mode and electronic gearing settings.
Check BAT.LOW on the bench. Follow Delta’s maintenance procedure for battery service.
Test Y0 and Y2 under conditions that match the drive input. Check the pulse frequency and direction signal separately.
Make the first move at low speed under safe test conditions. Check the direction and the distance traveled per command.
PDFs and internal references
Delta DVP PLC files · Delta DVP-PLC programming manual (PDF) · Delta DVP-EH · Delta DVP PLC series
External references
Delta DVP-EH instruction sheet, 2006 · Delta ASDA-B manual and DVP32EH00T example · Delta DVP cable reference · Delta WPLSoft and ISPSoft information