oc • Output overcurrent
The drive detected a sudden rise in output current. Note whether the fault appeared as the motor started or when the machine load increased. Compare the motor nameplate current with the drive rating. Have maintenance check the motor circuit if a short is suspected. Record the conditions before reviewing the current limit and torque compensation.
ocA, ocd, ocn • Acceleration, deceleration and steady speed
ocA occurs during acceleration. Check for binding, a short ramp or high torque compensation. ocd occurs during deceleration. Review the stop time and have the motor circuit checked. ocn occurs at steady speed. Look for sudden load changes or a jam. Save the existing ramp times before making changes.
GFF • Output ground fault
The drive detected a ground fault on the motor side. Have qualified staff isolate the drive and separate the motor and output cable from it before testing. Repeated GFF trips may also require a check of the power stage. The manual lists the GFF hardware fault separately as HP.F.. Record the full display for service. See the IGBT power stage overview for context.
ou / OV • DC bus overvoltage
If it trips during deceleration, review regenerated energy and the stopping ramp. A trip at power-up or off load points to the supply and possible voltage transients. For this DC bus fault, use the exact drive model and braking duty when selecting dynamic braking components or a braking resistor.
Lu / LV • DC bus undervoltage
The drive detected low DC bus voltage. Check whether the fault coincided with a supply interruption, another large load starting on the same feed or the machine starting. Verify the single-phase or three-phase supply on the nameplate. Have a qualified electrician check the incoming circuit against the wiring diagram.
Motor does not run or its speed stays fixed
Check whether the keypad is active, whether the drive sees RUN and where the frequency reference comes from. If the motor runs at one speed, review the frequency limits, analog reference and selected preset speed input. For a startup stall, check the load and ramp. For intermittent commands, have the power and signal cable routing checked before selecting an EMC filter.
Read the last three faults
Pr.73 shows the latest fault, Pr.74 the preceding fault and Pr.75 the third most recent fault. Once the cause is cleared, the manual calls for a five-second wait before a keypad or terminal reset, with RUN off. Qualified staff must isolate the supply and verify DC bus discharge in accordance with the manual before working inside the cabinet.
For oH, oL, oL1, oL2, cF1, cF2, cE1 and PHL, see Fault Codes, Part 2. EF signals an external fault input. bb indicates external Base Block. See PDF page 134 for the two entries.
Editor’s note
Photograph the display while the fault is present. Small differences in the characters are easy to misremember.
Write down what the machine was doing when it stopped. For ou during stopping, start with that part of the cycle.
If it worked yesterday, look for a change in the motor, cable or load.
For repeated GFF trips, stop resetting and have the motor, cable and power stage checked separately.
Write down the old parameter value before changing it so you can restore it if needed.