6ES5 951-7ND32
Siemens 6ES5 951-7ND32 SIMATIC S5 PS 951 Power Supply
The Siemens 6ES5 951-7ND32 is a PS 951 rack power supply for S5-115U and S5-115H controllers. It takes a nominal 24 V DC input and supplies the 5 V DC rack rail. It is rated at 7 A without a fan and 15 A with the Siemens-specified fan arrangement. The product listing specifies supply without a backup battery.
The PS 951 powers the SIMATIC S5 CPU, the programming-device interface and the control circuits of the modules in the S5 rack. If the rack runs but the field outputs remain off, trace the I/O load supply separately. Use the machine drawing to identify where the rack input and the field supply each receive 24 V.
When do the 7 A and 15 A ratings apply?
Include the CPU and every module drawing power from the rack in the load calculation. For a CPU 944, CPU 945 or any fitted S5 interface modules, use the current figures for the full order numbers. If the calculated load exceeds 7 A, apply the 15 A rating only with the specified rack cooling in place.
Record the full chassis number, for example CR 700-2 6ES5 700-2LA11 or 6ES5 700-2LA12. Among the long-rack accessories, the 6ES5 981-0HA11 fan unit takes AC and the 6ES5 981-0HA21 takes DC. Check the chassis number before selecting a fan unit or a 6ES5 981-0GA11 mounting kit.
How does it differ from similar PS 951 models?
The 6ES5 951-7ND12 also has a 24 V DC input and a 7/15 A rating. The 6ES5 951-7NB13 is a 24 V DC, 3 A version, while the 6ES5 951-7LD12 takes 120/230 V AC. If considering a 7ND31, 7ND41 or 7ND51 for replacement, compare the input, cooling and wiring against the documentation for that version.
Isolation details. Table 3.7 in the German Siemens S5-115H manual lists the 7ND32 as isolated. The following page also includes it among units described as having no galvanic isolation between the 24 V and 5 V sides. Use the unit and machine wiring diagrams to verify protective earth and reference connections.
Editor’s note
Record the rack and power supply nameplates together. Enter the 7ND32 suffix, rack order number and fitted fan order number separately on the service ticket.
Check cooling if the rack drops out after warming up. Record when the fault appears. After safe isolation, inspect the fan, airflow path and any fitted filter.
Verify the backup before removal. On racks with a CPU 941 or CPU 942, confirm that the program and required machine data can be restored. Record the fitted S5 memory card type and the condition of the backup battery separately.
Label the front connections. After safe isolation, match the 24 V input, reference terminals and any external backup supply to the drawing before disconnecting the S5 cables and connectors.
Identify which part of the system lost power. If the central rack still runs and only the ER 701-2 expansion rack is down, check the expansion rack supply and the inter-rack link separately.
OtomasyonAVM resources and PDFs
For hardware pages, see About Siemens S5 PLCs and S5-90U/115U central controllers.
SIMATIC S5-115H system manual (English, rack and power supply layout) · Siemens S5 PDF archive. For the exact 7ND32 entry, see printed page 3-38 of the German Siemens manual below.
Related topics
PS 951 7ND12 · PS 951 7ND41 · PS 951 7ND51 · 24 V DC long-rack fan
S5 navigation
Siemens S5 PLCs · S5 power supplies · S5 racks
Siemens and other external references
Siemens S5-115H manual, Table 3.7 and pages 3-38–3-39 (German, exact 7ND32 entry, current ratings and installation note)
ADEGIS 6ES5951-7ND32 product record (S5-115U/H application and backup battery details)