6ES5 701-2LA11
Siemens 6ES5 701-2LA11 ER 701-2 distributed expansion rack
The 6ES5 701-2LA11 is an ER 701-2 mounting rack for distributed I/O expansion in a Siemens S5-115U system. The S5 mounting rack family, S5 CPU range and CPU 942 pages help identify the central controller and its expansion hardware.
Slot count and comparison with the 2LA12
Parts lists describe the 2LA11 as having eight free module positions, while another parts listing gives seven. Use the slot markings and installed interfaces to establish the usable I/O positions. Siemens ST 50 shows the 6ES5 701-2LA12 with seven I/O modules in a distributed arrangement. See the ER 701-1 for centralized expansion and the ER 701-3 for a different slot arrangement.
Distributed connection and power supply
When replacing a rack, record the full order number of the S5 power supply. The PS 951-7LD11 is one of the supplies listed for the S5-115U in period documentation. Use the manual for the installed unit to confirm how the expansion rack is powered and what load the supply can carry.
Check the actual S5 interface modules fitted at each end. In the Siemens IM 304 / IM 314 example, the IM 304 is in the central rack and the IM 314 is in the expansion rack. In installations using an IM 306 or an IM 318, confirm the role of each module against the wiring drawings.
For the IM 304 / IM 314 link, Siemens shows a 6ES5 721-series cable and a 6ES5 760-1AA11 terminator on X4 of the last IM 314. Use that wiring example when the same interface pair is fitted. The S5 cables and connectors page helps identify the cable by its order number.
Slot layout and used-rack checks
Record the slot number for every digital input, digital output and mixed I/O module before removal. Ask for close-up photos of the backplane and its connectors before buying. When comparing other S5 expansion parts, check the full order number and the rack layout.
Editor’s note
1. Record the layout before removal. Photograph the rack nameplate, module order, interface switch and jumper positions, and the cable entry and exit points.
2. Separate rack faults from channel faults. If the entire rack drops offline, start with the power-supply indicators and the distributed link. If one channel drops out, inspect its field supply and front connector.
3. Check the end of the chain. On an IM 304 / IM 314 link, look for the 760-1AA11 terminator at X4 of the last IM 314. For a different interface, use its own wiring diagram.
4. Inspect the connections. After safely isolating power, check the rack sockets for bent pins, corrosion and loose guides. Return each module to its recorded slot.
5. Compare the spare slot by slot. Before changing to a 2LA12, compare the position reserved for the interface, the numbered I/O positions and the backplane markings.
6. Verify I/O before returning to service. With the machine in a safe test state, check the inputs on the PLC diagnostics screen and then verify the outputs individually under the test procedure.
Manuals and PDF archive
In the S5-115U manual, Figure 3-11 shows the ER 701-2 family layout and Figure 3-20 covers the IM 304 / IM 314 link. ST 50 page 3/65 lists the 2LA12 order number. Siemens S5 PDF archive.