6ES5 984-1UA11
Siemens 6ES5 984-1UA11 — Powered Adapter for PG 605U / 511
Siemens 6ES5 984-1UA11 is a 984 intermediate adapter, supplied with a power supply, for connecting a PG 605U programmer and printer to a 511 programmer interface. This auxiliary connection assembly in the Siemens SIMATIC S5 family is selected for the required arrangement between the PG 605U and programmer interface.
Siemens ST 53 identifies the exact 6ES5 984-1UA11 part number as a PG 605U accessory. Check the installed 511 interface revision and S5 CPU arrangement together. An adapter supplied with a power unit is a different component from the rack’s main CPU power-supply module.
PG 605U and printer connection
Siemens’ PG 605U manual lists 984-1UA11 as an adapter with a printer connector. Identify the exact programmer hardware, including any other PG 605U revision, and the intended PLC system. Its field role is to support the appropriate connection arrangement for STEP 5 programming and program printouts.
Test programmer operation separately from printer data transfer. A working PG display does not establish that the printer branch is healthy. Match the printer cable, electrical interface and settings together; a connector that fits is not sufficient evidence of compatibility.
AC 220 V supply and power-unit matching
The spare-parts list in Siemens’ PG 615 manual identifies 6ES5 984-1UA11 as the “AS 511/PG 605U adapter, AC 220 V”. For a used assembly, check the power-unit label, connecting cable and whether the unit belongs with this adapter. Do not transfer output-voltage or current ratings from another 984 model.
Inspect the supply unit before applying mains power. Check S5 cables and connectors for damage, loose contacts and later modifications. Assess grounding and signal-reference connections against the equipment’s own wiring arrangement. Do not apply external voltage to unidentified pins.
TTY communication and addressing
The PG 605U manual describes the programmer’s communication interface as a serial TTY current loop. This does not make every adapter connector an RS-232 port. A USB-to-RS232 converter alone does not provide compatibility with the existing TTY connection; verify the cable and electrical interface together.
The 984-1UA11 is not used by assigning channels or a starting byte address like a digital I/O board. Trace the connection path between adapter, PG, 511 interface and printer. Do not apply a generic D-sub pin assignment without a verified connection drawing.
Differences from 1UB11, 2UA11 and other adapters
The PG 605U manual lists 6ES5 984-1UB11 as a separate adapter for the S5-101U. 6ES5 984-2UA11 belongs to the PG 615 adapter family. The shared “984” prefix does not establish identical supply and connection arrangements.
6ES5 984-0DA11 is a different adapter associated with the 335 diagnostic unit. A 501 programmer interface should not replace a 511 arrangement merely because the names appear similar. Match the 1UA11 suffix, power unit and complete cable assembly when selecting a spare.
Used-unit testing and preserving program data
During fault-finding, check connections and supply first, then verify data reading through the PG and finally printing with a suitable printer. When different 511 interface revisions are involved, check the installed system’s connection requirements separately. Record the PG and interface part numbers with the test result.
The PG 605U manual states that disconnecting the programmer causes its temporary memory contents to be lost. This does not mean that the PLC program is automatically erased. Distinguish controller program memory from the PG’s RAM buffer, and complete any required transfer or recording before disconnection. This distinction matters when preserving the only available program copy during Siemens S5 maintenance.
Editor’s note
Check whether the power unit and cable assembly are included. An adapter body on its own may leave you searching for missing parts before the system can be used.
Read the power-unit label before applying power. A supply borrowed from another adapter may look convincing. Investigate heat damage, hardened insulation or taped joints before proceeding.
A working PG display is only part of the test. Verify reading data from the PLC and producing a printer output separately; one function may work while the other has a cable or connection fault.
Match the drawing and cable before trying a familiar serial lead. TTY current-loop and RS-232 connections require different electrical arrangements.
Complete any work held in the PG 605U’s temporary memory before unplugging it. Preserve the required record and confirm the transfer so disconnection does not discard the programmer’s current work.
OtomasyonAVM resources and PDFs
Browse the 6ES5 984-1UA11 model page, S5 programmer interfaces and used Siemens equipment. General documents are collected in the shared Siemens S5 PDF archive. Manufacturer documents identifying the exact code are linked below.
Related topics
+ 6ES5 605-0UA11 — PG 605U handheld programmer.
+ 6ES5 511-5AA12 — 511 programmer interface.
+ 6ES5 984-1UB11 — separate adapter for a different controller connection.
+ 6ES5 984-2UA11 — PG 615 adapter family.
+ 6ES5 984-0DA11 — adapter associated with the 335 diagnostic unit.
Browse SIMATIC S5
S5 interface modules · S5 auxiliary modules · S5 cables · SIMATIC S5 · Siemens S5 PLC · Used Siemens equipment
Siemens and external references
Siemens ST 53 — SIMATIC S5-130 / S5-150, 1985 — Printed p. 9/7 / PDF p. 125: exact 984-1UA11 code, PG 605U/printer/511 arrangement and inclusion of the power unit.
Siemens PG 605U — Manual, EWA 4NEB 810 1056-02d — Printed p. 2-1 / PDF p. 13: 984-1UA11 printer adapter, the programmer’s TTY interface and loss of its temporary memory on disconnection.
Siemens PG 615 — Handbuch, 6ES5 998-0UR11 — Appendix C, printed p. C-1 / PDF p. 165: exact 984-1UA11 AS 511/PG 605U adapter, AC 220 V. The table identifies 984-2UA11 separately.