6ES5 393-0UA13
Siemens 6ES5 393-0UA13 – OP 393-IIC Operator Panel
Siemens 6ES5 393-0UA13 is an OP 393-IIC operator panel for SIMATIC S5. It has a two-line, 16-character-per-line LCD and physical keypad. Among Siemens HMI and operator panels, it provides a compact interface for working with timer and counter values and viewing PLC information locally.
The manual specifies 5.2 V / 0.1 A, supplied through the PLC connection cable, and a serial TTY 20 mA current-loop interface. Select S5 connecting cables and interface hardware accordingly. Do not apply 24 V directly to the connector or assume that an ordinary RS-232 cable is suitable.
CPU, cable and connection distance
Record the S5 CPU number, selected port and panel version shown at startup together. For S5-90U and the S5-90U/S5-115U CPU groups, compare the exact CPU and OP version with the manufacturer’s connection table rather than deciding from the series name.
Siemens specifies a 984 cable adapter for connections exceeding 3 metres. During S5 communication checks, verify cable length, adapter number and power arrangements. Perform industrial communication acceptance using the actual cable and adapter intended for the installation.
Distinguishing OP 393 versions
6ES5 393-0UA11, 6ES5 393-0UA12 and 6ES5 393-0UA15 are different order numbers. When selecting a replacement for 0UA13, assess power requirements, connection options, software version and required functions alongside the front-panel appearance.
6ES5 395-0UA11 OP 395 and 6ES5 396-0UA11 OP 396 belong to separate product families. The offer should identify the complete panel number and supplied cables. Association with the same PLC series does not establish direct interchangeability.
Timers, counters and data blocks
The OP 393 family provides timer/counter operations, message display and version-dependent data-word and diagnostic functions. Identify the relevant PLC program addresses and values permitted for operator changes. Record whether each displayed number represents a setpoint, actual value or another data area.
When reviewing PLC software and project files, check the DB6 parameter arrangement, text DBs and associated data words. Back up existing blocks before changing parameters or texts. About Siemens S5 PLC provides system background; verify the panel’s application mapping against the actual plant program.
Mounting and supplied contents
Check the 6ES5 982-3UA11 mounting frame separately for panel installation. When purchasing S5 accessories, establish whether the panel, frame, connecting cable and any cable adapter are included. Measure the existing panel cutout and inspect the frame before starting mechanical changes.
Editor’s Note
When buying an OP 393 as used Siemens equipment, request the rear label and startup display together. Record the 0UA13 order number and displayed version rather than relying on the front-panel name. Include photographs of the cable and adapter.
Establish the correct power and cable arrangement before connecting the panel. Use the specified supply information for this model. Obtaining the correct cable first avoids unnecessary repair work after a wiring mistake.
Test keys individually, including frequently used enter, clear and arrow keys. Check every character position on both display lines. Use the manual’s test procedure appropriate to the panel version and retain the results.
Startup alone does not demonstrate PLC communication. Read a known value from a suitable test CPU, then change and read back a permitted test location. Keep production timer and counter settings out of acceptance experiments.
If texts are missing or values appear incorrect, include DB structure, address mapping and version checks in the diagnosis. List the frame, cable and any adapter together at delivery. Establishing missing parts beforehand prevents an incomplete installation.
OtomasyonAVM resources and PDFs
+ Shared SIMATIC S5 PDF archive – S5-115 PDF files. The OP 393 manufacturer manuals are linked below; read the connection table together with function version notes.
Related topics
+ 6ES5 393-0UA11 · 6ES5 393-0UA12 · 6ES5 393-0UA15 · 6ES5 396-0UA11 · OP 393 mounting frame
Browse SIMATIC S5
+ Siemens HMI and panels · S5 cables and connectors · S5 accessories · Siemens SIMATIC S5
Siemens and external references
+ Siemens OP 393 Manual – English, 6ES5 998-0UQ22, EWA 4NEB 810 1180-02f. External archive copy of the manufacturer manual. Sections 1–3 cover connections, technical specifications and parameters; section 9 covers device tests.