6ES5 245-1AB12

Siemens 6ES5 245-1AB12 SIMATIC S5 IP 245 Servo Valve Control Module

+ OtomasyonAVM Siemens S5 PDF archive

Siemens 6ES5 245-1AB12 is an IP 245 function module that controls hydraulic servo valves in SIMATIC S5 PLC systems. This order number identifies the servo valve version in the S5 special module range. The Niemur service list identifies the exact part as a two-servo-valve version.

S5-115U installation. Siemens’ system manual lists 0.2 A on the internal 5 V rail and requires a fan and adapter casing for the IP 245. It lists the IP 245 as a double-width board in the 6ES5 491-0LB12 casing. Record the S5 rack and PS 951 power supply codes before replacement. For an expansion rack, also match the expansion hardware and IM interface.

Command and permissive signals. On a CPU 944 installation, use the correct PG connection cable to back up the STEP 5 project. Record the block that issues the valve command and the module address. Use the schematic to distinguish digital input permissives from digital outputs that drive field relays.

Field wiring. Label the front plug, S5 cables and any feedback sensor connectors. If the machine has separate analog modules, identify the feedback read by the analog input and any command sent by the analog output in the schematic. Use the machine wiring diagram for the 1AB12 pin assignments and valve output range.

Systems with several function modules. The IP 243 can process analog signals, while the IP 240 and IP 241 can process position data. If the machine also has IP 246 positioning or IP 252 closed-loop control, use the STEP 5 project to identify each board’s address and role during troubleshooting.

Editor’s note

Read the label. Compare the full 6ES5 245-1AB12 order number and hardware revision with the removed board. Siemens used the IP 245 name for both servo and proportional valve versions.

Before removing the board, follow the machine’s energy isolation procedure and verify that stored hydraulic energy has been made safe. Photograph the front plug and slot position.

If one valve fails to respond, monitor its command and permissives in STEP 5. If the command is present, use the machine schematic to trace that channel through the front plug, cable and valve-side wiring.

If both valves fail to respond, check shared permissives, field power and the rack’s 5 V rail. If the fault develops after warm-up, check that the S5-115U fan runs and that air can flow through the rack.

Where a suitable bench setup is available, test both valve channels of the spare. Record the load and command directions tested on each channel.

Related topics

+ Siemens IP 246 positioning module

+ Siemens IP 252 closed-loop control module

+ SIMATIC S5 racks

Siemens second-hand menu

+ S5 special modules

+ SIMATIC S5

+ Second-hand Siemens automation equipment

When buying a used board, ask for the label photo, whether the front plug is included, and the channel test record. To sell one, send the order number, quantity, working condition, label photo and asking price to otomasyonavm@gmail.com.

External references

+ Siemens S5 to S7-1500 migration guide, Table 7-9

+ Siemens S5-115U system manual, IP 245 entry

+ Niemur service list, 6ES5245-1AB12 (DE)