6ES5 947-3UA22

Siemens 6ES5 947-3UA22 — S5-155U CPU 947 memory and interface unit

Siemens 6ES5 947-3UA22 is the memory and interface unit (MAI) of the S5-155U CPU 946/947 assembly in the Siemens S5 family. It operates together with CPU 946 in the SIMATIC S5 system. Identify its role within the processor assembly in purchasing and maintenance records.

When comparing it with the 6ES5 946-3UA22 CPU 946, keep the two boards’ roles distinct. If only CPU 947 is supplied, do not assess it as a complete working CPU assembly. Record the installed CPU 946 number, board versions and system layout as well.

Internal memory versus the 896 KB configuration

Internal user RAM is 128 KB (64 Kwords). 896 KB is the maximum total with 355 memory expansion. When checking S5 memory products and expansion equipment, identify the installed boards and memory submodules individually.

An advertisement describing an “896 KB CPU” does not establish that this capacity is present in the supplied assembly. Compare RAM and EPROM submodule numbers, quantities and actual program size. Keep the user-program backup together with the machine’s parameter records.

Power and rack checks

CPU 947 is specified for 5 V DC ±5%, drawing approximately 2 A. Include CPU 946 and other modules when assessing the power supply. Use the system’s designated measurement points rather than probing unidentified contacts.

Photograph the rack arrangement, rear connectors and retaining parts before removal. After switching off and appropriately isolating the equipment, inspect for bent contacts, loose connections or physical damage. Verify the original board’s role and location before fitting the replacement.

PG connection and access through the coordinator

The front PG connector has 15 pins; serial speed is 9600 bit/s. Select the appropriate S5 programming cable and interface equipment from the installed wiring arrangement. Connector shape alone does not establish electrical compatibility.

PG access through the CPU 947 front port and the 923C coordinator must not be used simultaneously. During communication checks, establish which access path is connected first. Record the cable, adapter and PG settings before concluding that a connection fault is inside the board.

Related numbers, addressing and project checks

Keep versions such as the CPU 946-3UA21 and CPU 946-3UA23 distinct from nearby numbers such as the CPU 947-3UA11 and CPU 947-3UA21. Include the complete suffix and hardware version in comparisons. Do not transfer memory and interface specifications for the CPU 948-3UA23 to this board.

Compare digital input, digital output and analog module addresses in the STEP 5 project with the installed hardware list. Replacing a board is not a reason to change addresses or jumper settings by guesswork.

OVERALL RESET erases and initializes all RAM areas. During PLC troubleshooting, do not use it as a trial step without a backup and recovery method. Record LED indications, PG access and the conditions under which the fault occurred first.

Editor’s note

When buying a used Siemens CPU 947, start by establishing exactly what is supplied. Is it the single board, is CPU 946 included, and is memory expansion part of the package? The photographs and description should make this clear.

Do not confuse 128 KB of internal memory with an expanded 896 KB system. If a larger capacity is advertised, request photographs and identification numbers for the installed memory. Check that the stated capacity matches the delivered components.

Applying power alone does not establish a complete test. Request PG connection, program and memory checks together with a suitable CPU 946. Know which supporting components were used before accepting a general “working” description.

Photograph and record jumper positions before intervention. Do not move links to match a photograph of another revision. Belonging to the same family does not establish identical settings.

Back up the machine program before removing the existing board and check that the file opens. Resolve PG connection problems first rather than risking the only program copy during a board change.

For S5 maintenance, keep the CPU 946 and CPU 947 numbers, installed memories, connection path and completed tests on one record. The next technician should not have to guess which components were tested or under what conditions.

OtomasyonAVM resources and PDFs

+ Siemens S5 PDF archive: system and module documentation. The CPU 946/947 manufacturer manual is linked below.

+ 6ES5 947-3UA22 model page and second-hand Siemens S5 models: the product and related system components.

Related topics

+ 6ES5 946-3UA22 CPU 946 · 6ES5 947-3UA21 · 6ES5 947-3UA11: role and version comparisons; interchangeability should not be assumed.

+ 923C coordinator · S5 memory products · S5 cables: other assembly components.

Browse SIMATIC S5

Product page · Siemens S5 · SIMATIC S5 · Used Siemens equipment