6ES5 921-3WA13
Siemens 6ES5 921-3WA13 — S5-130WA CPU 921 central processing board
Siemens 6ES5 921-3WA13 is a CPU 921 central processing board for the WA version of SIMATIC S5-130W. This CPU in the Siemens S5 family executes the installed PLC program. Siemens’ SINUMERIK System 3 service documentation also identifies the 130WA PLC arrangement with the 921-3WA processor family.
When selecting a spare, check the 3WA13 suffix, board revision and fitted memory together. WB versions such as 921-3WB11 and 921-3WB13 require separate assessment. The shared name “CPU 921” does not establish interchangeability between versions.
WA processor construction and timing
Siemens’ AG 130WA CPU 921 maintenance drawing shows a U1 main board and U2 additional board. It specifies a 16 MHz nominal frequency for normal operation. This is the WA family’s clock frequency, rather than the user-program scan time or execution time of an individual instruction.
The WA document associates the A–B jumper on U1 with the 0.01-second time base. Assess its setting against the program’s timing requirements. Siemens states that factory-fitted jumpers must remain unchanged, with the documented exception for this jumper. Record the installed positions before maintenance.
Program memory and NC connection
The WA section of the SINUMERIK System 3 manual separately covers the 350 program memory board and 03800 A PLC coupling board. Inspect memory modules and the RAM/EPROM arrangement separately from the processor part number. Fitted memory does not establish that the correct machine program is present.
Assess the processor, memory and coupling board together within this architecture. Record the complete part numbers of the rack, expansion hardware and interface boards. Check the target installation before transferring another machine’s connection arrangement.
STEP 5, field signals and diagnostics
For STEP 5 programming, select the programmer model, installed connection hardware and programming cable together. Preserve the existing program and memory contents first; avoid experimental memory clearing when investigating a connection fault.
Assess digital inputs and digital outputs according to the installed peripheral boards. During fault-finding, examine the CPU state together with field power, I/O boards and the PLC–NC connection. Include supply, cooling and backup condition in the S5 maintenance record.
Differences between CPU 921 versions
6ES5 921-1AA21 is a different CPU 921 model for S5-130A/130K, while 6ES5 921-3UA12 belongs to S5-135U. 921-3WB14 and 921-3WB15 are separate WB-family order versions. Replacement decisions across WA, WB, UA and 1AA codes require verification of the system and revision match.
Editor’s note
When buying used Siemens equipment, inspect the 3WA13 label, both sides of the board and the fitted memory. Obtain the complete part number if a photograph shows only “921”.
Inspect the main and additional boards as an assembly. Check for a missing additional board, loose connection or removed memory; avoid combining parts from different revisions without verification.
Photograph the U1 and U2 jumper settings. Do not change the time-base jumper simply to increase machine speed. Establish how the existing program uses the timers before considering a documented change.
Check connector contacts, oxidation, cracked solder joints and previous repairs before installation. Remove or insert the board with system power off and suitable static-discharge protection.
Verify program loading, the PLC–NC connection and relevant I/O responses in a suitable test arrangement. Back up the machine program and record the memory and coupling boards alongside the test result.
OtomasyonAVM resources and PDFs
6ES5 921-3WA13 model page · SIMATIC S5 CPU family · Used Siemens equipment. For other S5 documents, visit S5-115 PDF files. References for the WA processor family are linked below.
Related topics
+ 6ES5 921-3WB11 — a different CPU 921 in the WB family.
+ 6ES5 921-3WB13 — another WB-family order version.
+ 6ES5 921-1AA21 — a different CPU for S5-130A/130K.
+ 6ES5 921-3UA12 — a different CPU for S5-135U.
Browse SIMATIC S5
Siemens S5 · S5 CPUs · S5 racks · S5 memory · S5 interfaces · S5 cables · Used Siemens equipment
Siemens and external references
Siemens System 8 — Inbetriebnahmeanleitung, PC-Teil, I/2 — German. Section 5.7, PDF p. 38 / printed 5-13, A 12.83: AG 130WA CPU 921, U1/U2 construction, nominal frequency and jumper notes. Family documentation, rather than a 3WA13-specific current or memory-capacity data sheet.
Siemens SINUMERIK System 3 — Service Manual, Part 1, Edition 12/85 — Externally archived English Siemens manual. Section 11.1 covers 130WA; 11.1.1.1–11.1.1.3 identify 921-3WA, 03800 A and the 350 memory board. The WB arrangement is covered separately in section 11.2.