6ES5 318-8MA12

Siemens 6ES5 318-8MA12 – ET 100U IM318-8 Serial Interface Module

The 6ES5 318-8MA12 is an IM318-8 serial interface module for ET 100U distributed I/O stations in SIMATIC S5 systems. Part of the S5 interface module range, it exchanges station data with the controller through the IM308 6ES5 308-3UA12 on the central CPU side.

The nominal supply is 24 V DC, with a permitted range of 20–30 V DC. Use a suitable PLC power supply. The ET 100U supports up to 16 bus units, 32 modules and a 32-byte address volume. Select digital input, digital output and analog modules within that address limit; bus units such as the 700-8MA11 provide the module connection structure.

Serial communication and baud rate

The selectable rates are 31.25 / 62.5 / 187.5 / 375 kbit/s. Set the nodes to the same rate as the IM308. The selected rate affects the cable requirements and permissible distance. Assess shielded twisted-pair cabling and grounding together; the highest rate cannot be used at every cable length.

Bus units and multiple tiers

For a multiple-tier layout, select the appropriate IM315 315-8MA11 or IM316 316-8MA12 arrangement. When considering cables such as the 712-8AF00, 0.5 m and 712-8BC50, 2.5 m, check which interfaces they connect. The local tier connection and the serial field connection to the IM308 serve different purposes.

Address list and program mapping

ET 100U module addresses are transferred to the station from an address list stored in the IM308's EPROM. Assess the PLC program, actual module sequence and existing COM ET 100 configuration together. Preserve the address list and project files before changing the interface module.

Distinction from ET 200U interfaces

The 8MA12 is intended for ET 100U. ET 200U interfaces such as the 318-8MB11 and 318-8MC12 belong to different system arrangements. Do not configure this ET 100U serial link as a PROFIBUS-DP slave connection. Match the complete order number and central interface when selecting a spare.

Indicators and fault checks

The front panel has ON, I/O DISABLED, I/O-FAILURE and ALARM OUTPUT indicators. During troubleshooting, compare the complete indicator pattern with the manual's table; avoid diagnosing the module from one lamp alone. Check the supply, serial link, ON/OFF switch and local bus connection in sequence. Our Siemens S5 PLC overview provides general system context.

Editor’s note

Photograph the IM308 label at the other end when looking for this spare. The central interface code matters alongside the station interface code. Knowing both ends reduces the chance of ordering the wrong part.

If communication stops, check the supply and ON/OFF switch first, then the cable and bus units. A small connection problem in an older system can send you looking for a faulty board for hours.

Look after the address list and COM ET 100 files. Boards can be replaced and cables sourced; reconstructing a lost module sequence and address map takes more work. Secure the backup before starting.

Leave a working baud-rate setting alone unless there is a reason to change it. The cable and distance must support the selected rate. A record of settings that run the machine properly is more useful than an unplanned experiment.

For a used spare, ask for more than an illuminated ON indicator. Where practical, check communication with an IM308 and actual I/O data transfer. Keep the old board labelled until the replacement arrangement has been checked in operation.

OtomasyonAVM resources and PDFs

+ S5 interface modules and 308-3UA12 IM308: station and central interface information.

+ S5 cables and connectors and PLC troubleshooting: connection and maintenance topics.

+ Siemens S5 PDF archive: our available documentation page. The ET 100U manual below includes the exact 318-8MA12 order number and its technical specifications.

Related topics

+ 315-8MA11 · 316-8MA12 · 712-8AF00 · 712-8BC50: multiple-tier layouts and connection parts.

+ 318-8MB11 · 318-8MC12: distinguishing ET 100U and ET 200U interfaces.

Browse SIMATIC S5

S5 interface modules · S5 cables · SIMATIC S5 CPUs · Siemens S5 PLC · Used Siemens equipment

Siemens and external references

+ Siemens ET 100U Distributed I/Os Manual – English, EWA 4NEB 812 6040-02a: p. 2-11 specifications, Chapter 3 installation, Chapter 4 start-up and Chapter 5 diagnosis.

+ Siemens S5-135U/155U System Manual – English, C79000-G8576-C199-07: p. 2-5, ET 100U connection using IM308 and IM318-8.

+ Siemens ST 50 · 1998 catalogue – English, p. 3/90: IM308, IM318-8 and 376 EPROM ordering information; third-party archive copy of a Siemens publication.