6ES5 941-7UA13
Siemens 6ES5 941-7UA13 — S5-115U CPU 941 with 2 KB internal RAM
Siemens 6ES5 941-7UA13 is the S5-115U CPU 941 central processing unit in the Siemens S5 family. Siemens identifies this order number with 2 KB RAM. In a SIMATIC S5 installation, it executes the user program, evaluates inputs and generates output commands. It has one serial port for programming connections.
When comparing with 6ES5 941-7UA11, 6ES5 941-7UA12 or 6ES5 941-7UB11, consider more than the CPU 941 name. Check the complete number, hardware version and existing program together. Do not transfer memory or performance specifications from a different processor such as the CPU 942-7UA13.
Internal RAM and external memory capacity
The 2 KB internal RAM differs from the 18 KB total user area possible with a memory submodule. When checking S5 memory products, record internal and submodule capacities separately. Also establish whether a memory submodule is included with the used CPU.
The manual lists options for CPU 941 such as the 6ES5 375-0LA21 EPROM, 6ES5 375-0LC41 EEPROM and 6ES5 375-0LD21 RAM. Verify memory type and programming number. Do not assume that the full capacity of a larger submodule used in another CPU is available here.
Program resources and backup
The CPU 941 manual specifies 128 timers, 128 counters and 2048 flag bits. Retention depends on the selected settings and battery backup. Compare the areas used by the program with the installed settings.
When backing up the STEP 5 project, retain more than screenshots of Ladder or function block representation. Archive the program file, available comments and machine parameters together. Check that the file opens and the equipment needed for recovery is available.
PG port and communication connection
The 15-pin TTY connection supports PG, operator-panel or suitable SINEC L1 connections. Select the S5 programming cable against the port’s own wiring diagram. A matching plug does not make an ordinary RS-232 cable electrically suitable.
Record the interface connection and communication arrangement alongside the existing cable labels. If another device uses the single port, establish the machine impact of disconnecting it for PG access. Do not plan as though the CPU has a second serial port or replaceable SI2 submodule.
Addressing and commissioning checks
Photograph the rack arrangement, power supply and installed modules before removal. Compare digital input, digital output and analog module addresses with the existing project and module documents. Do not equate a slot number directly with a program address.
During PLC troubleshooting, record LED indications, information available through the PG and the conditions under which the fault occurs. OVERALL RESET erases RAM contents. Do not use it as a trial step without a verified backup and recovery method. Include the installed memory contents in the maintenance record.
Editor’s note
When buying a used Siemens CPU 941, make sure the label clearly reads 7UA13. A general “CPU 941 available” description is insufficient. Request photographs of the version marking, memory receptacle and rear connectors.
Do not confuse 2 KB of internal memory with the total capacity of a submodule-equipped assembly. If a larger figure is advertised, identify the fitted submodule by number and photograph. Do not price a missing submodule as though it were included.
A lit RUN indicator does not establish a complete test. PG connection, program read/load and memory checks should be demonstrated separately. Record the supporting equipment used for the demonstration.
Back up the machine program first and check that the file opens. A handwritten EPROM label does not establish that its contents are current. Investigate changes made later on the machine.
If data disappears after a power interruption, inspect the battery, connections and backup arrangement before replacing the CPU. Perform power-interruption checks only after verifying the backup and preparing a recovery method.
For S5 maintenance, keep a clear record. The CPU number, version, memory submodule, cable type and test results should be on one form. Distinguish completed checks from functions that have not been tested.
OtomasyonAVM resources and PDFs
+ Siemens S5 PDF archive: system and module documents. The original CPU 941 manual is linked below.
+ 6ES5 941-7UA13 model page and second-hand Siemens S5 models: the CPU and related system parts.
Related topics
+ 6ES5 941-7UA11 · 6ES5 941-7UA12 · 6ES5 941-7UB11 · 6ES5 942-7UA13: number and version comparisons; direct interchangeability should not be assumed.
+ S5 memory products · S5 cables · PLC debugging: memory, connections and maintenance.
Browse SIMATIC S5
Product page · Siemens S5 · SIMATIC S5 · Used Siemens equipment
Siemens and external references
+ Siemens Industry Mall — 6ES5 941-7UA13: complete order number and 2 KB RAM description.
+ Siemens S5-115U CPU 941/942/943/944 Gerätehandbuch — 6ES5 998-0UF12, Ausgabe 03, German. Chapter 2: CPU 941 architecture and memory; Table 2.8: memory options. Document: GWA 4NEB 811 6000-01b.