6ES5 450-3AA11
Siemens 6ES5 450-3AA11 — 32-Channel, 24 V DC / 120 mA Digital Output Module
6ES5 450-3AA11 is a 32-channel, 24 V DC / 120 mA electronic digital output module in the compact K construction of Siemens SIMATIC S5. This model in the S5 digital output range has a field-supply range of 20–30 V DC and two galvanically isolated groups of 16 outputs.
The Siemens ST 53 catalogue lists this exact order code for S5-130K/W and S5-150K/S systems. Within SIMATIC S5, check compact K construction, addressing and the existing rack arrangement together. Dimensions are 19 × 244 × 202 mm, with an approximate weight of 0.3 kg.
Supply and channel load
The switching-current range for resistive and inductive loads is 0.2 mA–120 mA. Select an appropriate 24 V DC power supply; follow the wiring diagram for each group’s feed, return and grounding. Maximum total switching current is 1.92 A per group of 16 outputs.
Before connecting a contactor or valve coil, check steady-state and inrush current. 120 mA is not 0.5 A. A load exceeding the rating requires a suitable driving arrangement, such as an interposing relay whose own coil current also suits the output. Lamp loads have a separate maximum rating of 2.4 W.
Fuse groups and temperature limits
There is one T 2.0 A slow fuse per group of 16 outputs. Electronic short-circuit protection does not remove the need for the correct fuse characteristic. If a fuse opens, inspect the load and wiring; do not fit a higher-rated fuse to keep the circuit running.
The operating-temperature range is 0–55 °C. ST 53 limits the total load at 55 °C to 80% of the sum of all output rated currents. Apply this temperature-dependent total-load limit together with the 1.92 A limit for each group.
Switching and field wiring
Maximum switching frequencies are 100 Hz for resistive loads, 11 Hz for lamps and 2 Hz for inductive loads at rated load. Maximum off-state leakage is 20 µA; the minimum on-state output voltage is supply voltage − 2.5 V. Assess these values together with the actual load current.
For S5 field cabling, ST 53 gives maximum lengths of 400 m unshielded and 1000 m shielded. Check voltage drop, conductor size and interference conditions for the actual installation. These lengths do not guarantee operation with every load and cable.
Addressing, RDY and BASP
The 32 outputs occupy four output bytes. Match the addressing socket’s setting to the starting address in the PLC program. Check that the programming software is monitoring the correct byte and bit; do not copy an address from another machine without verification.
Jumper Br1 determines how RDY acknowledgement relates to the address and MEMW signal; Br2 determines whether BASP is effective. Record the original socket and jumper settings before replacement, then compare them with the exact model’s diagram. Do not change these settings by trial and error to make an output operate.
During troubleshooting, check the program command, group supply, fuse and load return together. Also check the relevant digital input conditions and S5 system operating state. Isolate system and field power before disconnecting wiring.
Comparison with other K-type outputs
The 6ES5 445-3AA12 is rated 32 outputs / 0.5 A, the 6ES5 451-3AA11 16 outputs / 0.5 A, and the 6ES5 444-3AA11 16 outputs / 2 A. They serve different load requirements. Channel count, isolation and wiring differ, so do not assume direct interchangeability.
Editor’s note
Keep the 120 mA limit in mind from the start. A “24 V” label does not mean every coil suits this output. Checking the coil current now is easier than looking for another board later.
If sixteen channels disappear together, give the board a fair check before condemning it. Start with that group’s supply and T 2.0 A fuse. If the fuse has opened, find the cause before fitting another one.
Photograph the addressing socket and jumpers before removing the old board. A setting that has worked for years is easy to lose and sometimes awkward to recover. Recording the RDY and BASP settings saves trouble later.
An output shown as active in the program does not establish that the load is receiving power. Measure at the load while operation is commanded. Check for supply sag and a broken return before looking further.
When buying a used Siemens 450-3AA11, ask for both groups to be tested with suitable loads. Have all thirty-two channels checked. A working first channel is good news; seeing the remaining thirty-one work is much more reassuring.
OtomasyonAVM resources and PDFs
S5 digital output modules · S5 racks and expansion units · Siemens S5 PDF archive. This model is documented in Siemens ST 53 / 1985, pp. 8/12 and 9/6, and on page 17 of the compact digital I/O operating instructions. These sources are in German.
Related topics
6ES5 445-3AA12 · 6ES5 451-3AA11 · 6ES5 444-3AA11 · What is a fuse? · PLC troubleshooting.
Navigation
S5 digital output modules · SIMATIC S5 · Siemens S5 PLC · Used Siemens.