6ES5 305-7LB11
Siemens 6ES5 305-7LB11 – IM 305 Rack Expansion Interface, 1.5 m Cable
The 6ES5 305-7LB11 is an IM 305 interface assembly connecting one expansion unit to an S5-115U central controller in the SIMATIC S5 family. Part of the S5 interface module range, it carries backplane signals and operating power between the central CPU system and the expansion rack.
The assembly comprises two modules permanently connected by a 1.5 m cable. The 6ES5 305-7LA11 has a 0.5 m cable; the 7LB11 suffix identifies the 1.5 m version. Check both ends of the assembly and the cable arrangement when selecting a spare.
Centralized connection for one expansion rack
The IM 305 connects a maximum of one expansion unit. The expansion side uses an ER 701-0 or ER 701-1 from the S5 rack range; see the 6ES5 701-0LA11 and 6ES5 701-1LA11 rack pages. The 1.5 m cable permits a suitable adjacent arrangement of the central and expansion racks.
Central racks include different CR 700 versions such as the 700-0LA12, 700-0LB11 and 700-1LA12. Check the interface slot and available module positions against the actual rack version. Record both central and expansion rack codes before selecting a replacement.
Power supply and current limit
The expansion rack receives power through the internal bus. Siemens specifies a maximum current of 1 A supplied to the expansion unit through the IM 305. This is not the interface's own consumption. Check the PLC power supply capacity and calculate the combined bus load of the expansion modules.
Fixed slot addressing and analog module restriction
An IM 305 arrangement uses fixed slot addressing in both the central controller and expansion unit. Addresses in the PLC program must match the physical positions of the digital input and digital output modules. Check the address layout before moving any module.
With this addressing arrangement, analog modules are restricted to slots 0–3 of the central controller; do not install them in the IM 305 expansion rack. The IM 306 / 6ES5 306-7LA11 provides different expansion and addressing options. Changing between IM 305 and IM 306 requires reviewing the rack configuration and addressing.
Installation and troubleshooting
Disconnect system power before removing the assembly. Protect its cable against crushing, tension and strain at the ends, and check grounding. During troubleshooting, assess the seating of both modules, connection contacts and the expansion rack's supply load together.
Preserve photographs of the original layout and a program backup before restarting the S5 system. After replacement, confirm actual expansion inputs and correctly addressed output operation as well as CPU operation.
Editor’s note
Treat the two modules and their cable as one complete assembly. If a listing shows only one end, ask to see the other. A photograph of the whole set can save you a second search for a missing part.
The 7LA11 and 7LB11 look similar, but cable length matters here. Measure the intended route and allow room for bends. A connection stretched just far enough to fit today can become tomorrow's intermittent fault.
A working slot layout on an older machine is worth preserving. Take a photograph and record the module positions before removal. Check addresses before using an empty slot; that small precaution can save a long fault-finding session.
Keep the 1 A limit in mind when adding expansion modules. Leave analog modules in the central rack under the IM 305 fixed addressing arrangement. Understand the existing setup before making changes.
For a used assembly, inspect the cable jacket and both ends closely. Where practical, request an I/O transfer trial with suitable racks. Keep the original set labelled until the replacement is verified; it remains a useful comparison if questions arise.
OtomasyonAVM resources and PDFs
+ Siemens S5 PDF archive: our documentation page for S5-115U system, installation and addressing manuals.
+ S5 interface modules · S5 racks · S5 cable types
Related topics
+ 305-7LA11 – IM 305 with 0.5 m cable · 306-7LA11 – IM 306
+ 701-0LA11 · 701-1LA11 · PLC programming and address checks
Browse SIMATIC S5
S5 interface modules · S5 racks · Siemens S5 PLC · Used Siemens equipment
Siemens and external references
+ Siemens ST 50 · 1998 catalogue – English, pp. 3/82–3/83: IM 305 construction, one expansion unit, 1 A limit and exact 305-7LB11 ordering code for the 1.5 m cable; third-party archive copy of a Siemens publication.
+ Siemens S5-115U Manual – English, EWA 4NEB 811 6130-02b: Section 3.2.5, Table 3-2 and Section 6.2.1; centralized expansion, fixed slot addressing and central rack slot restrictions for analog modules.