6ES5 470-7LB12

Siemens 6ES5 470-7LB12 SIMATIC S5 Analog Output Module, 8 × ±10 V

The Siemens 6ES5 470-7LB12 is an eight-channel 470 analog voltage output module for S5-115U and S5-115F controllers in the SIMATIC S5 family. It converts PLC commands into signals from −10 V to +10 V. The output stage is galvanically isolated from the S5 bus, and all eight channels share a common MANA reference. The minimum load resistance is 3.3 kΩ per channel and the nominal external supply is 24 V DC.

The module can send a speed reference to a drive or a process value to an analog indicator. If the receiver expects 0–10 V, the STEP 5 program can use the positive half of the output range. For applications that require a current signal, Siemens documents the 470-7LA12 for ±10 V and 0–20 mA and the 470-7LC12 for 1–5 V and 4–20 mA.

Which CPU and rack configurations use this module?

The S5-115U and S5-115F manuals contain wiring diagrams and specifications for the 7LB12. On an S5-115U with a CPU 941, CPU 943 or CPU 944, check the rack, slot and analog output start address alongside the CPU order number.

The CR 700-1 rack for S5-115U and the CR 700-2F rack for S5-115F belong to different system configurations. Record the existing slot and address settings before replacing a module. For an S5-115F installation, verify its use against the machine’s approved I/O plan.

How do you wire QV, S+ and S−?

Connect the load between the channel’s QV output and MANA. Terminate S+ at the positive side of the load and S− at the negative side, both at the load itself. The module senses the voltage there and compensates for cable drop. For an unused voltage output, Siemens specifies QV–S+ and S−–MANA jumpers at the front connector.

The wiring diagram for this order number shows 3 (QV), 4 (S+) and 5 (S−) for channel 0, 13 and 37 for MANA, and 1 (L+) and 47 (L−) for the external supply. The supply must stay within 20–30 V DC, including ripple. Use the diagram on page 15-54 of the S5-115U manual for the other channels.

The module uses a 46-pin front connector. Options include the 490-7LB21 screw-terminal connector, the 490-7LA11 crimp connector with contacts and the 490-7LA21 crimp connector without contacts. The similarly numbered 490-7LB11 screw-terminal connector has 24 pins.

What STEP 5 values correspond to −10 V, 0 V and +10 V?

The CPU writes a two-byte output value for each channel. The module uses 11 bits plus a sign bit. Values of −1024, 0 and +1024 correspond to −10 V, 0 V and +10 V, respectively. With the value left-justified and the four low bits set to zero, the output words are C000h, 0000h and 4000h. In the Siemens level measurement example, the 460-7LA12 analog input module reads the transmitter and the 7LB12 sends 0–10 V to the indicator.

The 7LB11, 7LB13 and other 470 models

The 470-7LB11 and 470-7LB13 are separate order numbers with eight ±10 V outputs. The technical page in the archived S5-115H manual covers the 7LB11. The same manual specifies additional hardware circuitry for redundant operation of a 470 analog output.

The 470-7LA13 and 470-7LC13 are the voltage and current output variants listed in Siemens catalog ST 50. The 470-8MA12 covers the same ±10 V range in a two-channel module for different S5 installations.

Editor’s note

When choosing a spare, check the 7LB12 suffix and the front connector order number together. Record the rack slot and output start address before removal.

If every channel loses its output, start with the supply at terminals 1 and 47 and the common MANA connection.

If the voltage is wrong on one channel, measure it at the receiver input. Confirm that S+ and S− reach the correct terminals on the same load.

Photograph the jumpers on unused channels before removing the connector. During replacement, check the QV–S+ and S−–MANA links against the manual.

With the machine in a safe test state, try several command values within the receiver’s input range. Record the output word and the voltage measured at the load.

OtomasyonAVM resources and PDFs

See the Siemens SIMATIC S5 PLC overview and the S5 analog module catalog.

Browse the OtomasyonAVM S5-115 PDF archive and the SIMATIC S5-115H manual with the 470-7LB11 wiring diagram.

Related topics

Compare the 470-7LB13 with eight ±10 V outputs and the signal range options on the 470-7LA12 and 470-7LC12.

Browse the S5 range

Siemens SIMATIC S5 › S5 analog modules

To sell a Siemens S5 module, email the full order number, quantity, working condition, label photo and asking price to otomasyonavm@gmail.com.

External Siemens references

+ SIMATIC S5-115U system manual, 470-7LB12 terminal assignment and specifications

+ SIMATIC S5-115U system manual, load wiring and STEP 5 output value table

+ SIMATIC S5-115F system manual, 470-7LB12 wiring and specifications

+ Siemens ST 50 catalog, pages 3/49–3/50, 470-7L output modules and front connectors