6ES5 501-5AA11
Siemens 6ES5 501-5AA11 — AS 501 Parallel Programmer Interface Module
6ES5 501-5AA11 is the AS 501 parallel programmer interface module used between a programming device and an older SIMATIC S5 controller. The documented arrangement in the PG 631 and PG 670 manuals uses a 50-pin PG connection and a maximum 3 m cable. The exact module specification gives 5 V supply, approximately 0.7 A consumption and a 0–50 °C operating range.
The PG 631 manual describes program transfer and testing with the S5-130A/K through AS 501. Functions include transferring the controller’s EPROM program into PG RAM, operating the controller from PG memory, displaying STATUS/RLO information and performing tests. Assess STEP 5 programming functions against the actual programmer and target controller.
Parallel connection and cabling
The PG 631 parallel interface connection uses a 50-pin CANNON connector. Siemens specifies the 6ES5 734-0..0 cable family and a maximum length of 3 m. When selecting an S5 cable and connector, verify the complete cable code, wiring and target system.
The stated 5 V / approximately 0.7 A values describe the interface supply. In an existing S5 installation, check supply and common connections against the actual card and connection drawings. The consumption rating alone does not identify an external terminal to energize.
Program transfer and testing with PG 631
The original PG 631 environment provides AWL and KOP representations. Select the programming environment according to the installed programmer hardware and software. Compare instruction-list and ladder-diagram documentation to ensure it belongs to the same program revision.
The manual describes STATUS and RLO/VKE (result of logic operation) display, together with control of outputs, flags, timers and counters. During fault investigation, examine program state alongside the physical input/output conditions. Tests that affect outputs require the machine to be in an appropriate safe condition.
During ON-LINE operation, the controller can use PG memory as its program memory. Confirm where the program is executing before disconnecting the link. Keep a permanent backup of the program and relevant S5 memory-module details; a copy held only in temporary PG memory is not a durable archive.
Differences from AS 500 and AS 511
The PG 631 manual distinguishes AS 501 for AG 130A/K from AS 500 for AG 010/110A. Review AS 500 versions such as 6ES5 500-7AA11 and 6ES5 500-7AA12 against their own target systems. Similar names do not establish direct interchangeability with AS 501.
511-series parts such as 6ES5 511-5AA12 and 6ES5 511-5AA14 also require separate assessment. The PG 670 manual describes 20 mA serial transmission for AS 511 and parallel transmission for AS 501. Select S5 communications parts by the required interface, rather than by a nearby order number.
Used-module selection and functional checks
Inspect the complete label, card revision, connector condition and existing cable together. With a suitable programmer and controller, check program reading, status display and link stability. Documenting the working arrangement of an older S5 system makes spare-part selection more reliable.
Editor’s note
Start with the labels on the programmer and controller. 130A/K, 130W and 110A are easy to confuse when working through an old panel. Take a moment to identify the system before buying a part simply because it belongs to the S5 range.
If the link will not work, check the cable, connector contacts and supply before putting the interface aside. An aged cable with one broken conductor or a poor contact can make a healthy AS 501 appear faulty.
Extending the cable may look convenient, but Siemens specifies 3 m maximum for this parallel arrangement. Use a known-good cable of the correct type and suitable length when isolating a fault.
If the machine runs while the programmer is connected, establish where its program is executing. PG memory can be part of the running system in this arrangement. Check the operating mode before unplugging a cable, even if the original intention was only to inspect the program.
For a used interface, ask for more than a clean photograph. The label, revision, cable and, where possible, a test on suitable equipment should be considered together. A record of the working setup and a program backup are valuable when maintenance is due.
OtomasyonAVM resources and PDFs
+ S5 interface modules · S5 cables and connectors · About Siemens S5 PLCs.
+ OtomasyonAVM S5 PDF archive. Use the PG 631 and PG 670 C manuals below for this older AS 501 parallel connection. Both documents are in German.
Related topics
+ 500-7AA11 · 500-7AA12 · 511-5AA12 · 511-5AA14. Verify the target controller and interface type separately.
+ EPROM memory · RAM memory · PLC troubleshooting · PLC programming.
Browse SIMATIC S5
+ S5 interface modules · SIMATIC S5 · Siemens S5 PLC · Siemens second-hand equipment.